MVR-64 GENERAL 1.1. Purpose With the MTA-64, the multiverter becomes capable of connecting to the MADI-TP variants used in DiGiCo and Soundcraft/Studer/Harman desks, which - although not officially standardized - have gained widespread acceptance because they are built into many desks and stageboxes. The MTA-64s relay logic eliminates the need for crossover cables and allows to use standard straight (1:1) cabling in all situations.
User's Manual DEVICE DESCRIPTION Top view Connectors on "MVR" side Connectors on "Console/Stage" side Multiverter Console or Optional: Extension-Box or Multiverter FlexLink Port MADI-TP Port Stagebox 2nd MTA-64 MADI-TP Port 2.1. LED indications Meaning ☼ DiGiCo (blue) DiGiCo mode selected Sc/St (white) Soundcraft/Studer/Harman mode selected...
MVR-64 PREREQUISITES 3.1. Multiverter Firmware Check ▶ MVR-mkII All firmware versions support the MTA-64. ▶ MVR-64 The MVR-64 requires at least firmware 4.0 for the MTA-64 to work. Please check and update if required (see below). To check the multiverter's firmware version: Press Recall , move to ...
User's Manual OPERATION ▶ MVR-mkII Either AES50/MADI-TP port can be used. The port's pinout (AES50 vs. MADI-TP) can be set internally in the Multiverter by jumpering (see MVR-mkII manual). The default is AES50 pinout. NOTE: If you use AES50/MADI-TP#2, you will need to set the MTA-64s internal address to #2 (see 5.1 Changing the MTA-64's address via jumper).
MVR-64 4.2. Connecting two MTA-64s The second MTA-64 needs to be jumpered to address #2 See chapter 5."Configuring the second MTA-64" for details. ▶ MVR-mkII Flexiverter FLX-* HDMI FlexLink Console MTA-64 or Stagebox #1 Cat5* Cat5 AES50/MADI-TP1 MVR-mkII HDMI MTA-64 Console (address 2) or Stagebox #2...
User's Manual 4.3. Software setup The easiest way of setting up the MTA-64 is by using the multiverter's web configuration. Simply type the IP address of the Dante module in your web browser and open the SETTINGS page. ▶ Web The settings [04] and [05] can be altered on the "SETTINGS"...
MVR-64 MVR-64 ▶ Front panel The mode setting is available through the "Function" menu. To adjust the value: Press the blue Recall button Move the cursor to ☼ Function by turning the encoder left or right Confirm OK (push the encoder) ...
Page 10
User's Manual Value Mode Num. 96k frame Pinout mode format (Console / Stagebox, use Straight/MDIX) AES-X213 Auto AES50 DiGiCo Straight Soundcraft/Studer DiGiCo MDIX (Crossover) Soundcraft/Studer AES-X213 Auto DiGiCo Straight Soundcraft/Studer DiGiCo MDIX (Crossover) Soundcraft/Studer Table 1: Mode numbers (numbers not listed are reserved) 1 Applies only to 96kHz operation, ignored in 48kHz...
MVR-64 CONFIGURING THE SECOND MTA-64 5.1. Changing the MTA-64's address via jumper The second MTA-64 needs to be jumpered internally to address "2". The jumper is located on the internal PCB. To access it: 1. Remove the four screws (two upper screws on each side). 2.
User's Manual SPECIFICATIONS Parameter Value Dimensions 83x39x52mm (WxHxD) Weight 128 g Operating 0..+70°C, non-condensing temperature Storage temperature -40..+85°C, non-condensing Power consumption +15V DC from multiverter, 2W max. Cable lengths MVR to MTA-64 / Cat5 5m max. MVR to MTA-64 / HDMI 5m max.
* Not covered by the warranty are any damages resulting out of improper use, willful damage, normal wear-out (especially of the connectors) or connection with incompatible devices. 7.2. Manufacturer contact Appsys ProAudio www.appsys.ch Rolf Eichenseher info@appsys.ch Bullingerstr. 63 / BK241 Phone: +41 43 537 28 51 CH-8004 Zürich...