The manual contains information about purpose, technical details, operating principle, design, and installation of the Freshpoint Eco 160(-E) (L055/L07/L1) unit and all its modifications. Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.
Page 3
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de Ensure that the unit is switched off from the supply mains before removing the guard. Do not attach the product to the support using glue or adhesives. Use only the fastening method specified in the "User’s manual".
The product Remote control Mounting kit Mounting template User’s manual Packing box DESIGNATION KEY Freshpoint Eco 160 – E L055 Operating module length _: 440 mm L055: 550 mm L07: 700 mm L1: 1000 mm Electric heater Air duct diameter [mm]...
The unit design is constantly being improved, thus some models may be slightly different from those described in this manual. The figure below shows the overall dimensions of the product (mm) ØD ØD Model øD Freshpoint Eco 160 (-E) Freshpoint Eco 160 (-E) L055 Freshpoint Eco 160 (-E) L07 Freshpoint Eco 160 (-E) L1 1000 1100...
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de DESIGN AND OPERATING PRINCIPLE The product consists of the operating module (item 1) with the outdoor housing and protective hood assembly (item 2). The operating module contains fans, heat exchangers, heaters and the control system.
Page 7
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de Models labelled as L055; L07; L1 feature an air duct extension node. When using these models, it is possible to manually shorten the product before mounting so that the value L mentioned on the figure in the “Technical data”...
If you can access the mounting site from the external wall side, a compensator pad can be used (delivered separately). The figure below illustrates a set of compensator pads and an example of their use for the Freshpoint Eco 160 unit in a wall under 440 mm thick.
Page 9
For as optimal match between the product length and wall thickness as possible, when the outdoor wall side is inaccessible, cut theoutdoor housing and extension node for Freshpoint Eco 160(-E) L055/07/1 models. The allowed values for wall thickness are specified in the table below.
Page 10
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de 1. Prepare a round core hole with a diameter of 172 mm in the outer wall with a downward slope towards the outside. min 300 3 º min 300 2. Detach the outdoor housing from the operation module.
Page 11
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de 4. To remove the bottom panel (item 1), pull the bottom edge towards yourself. Remove the upper decorative panel (item 2) from the work module by unscrewing the corresponding screws. 5. Put the mounting template on the wall. Align it with a building level. Afterward, mark the openings to insert dowels from the mounting kit and drill the holes of required depth.
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de CONNECTION TO POWER MAINS The unit is designed for connection to power mains with the parameters specified in the “Technical data” section. The unit is connected using a power cord with a mains plug pre-installed by the manufacturer, or through fixed wiring.
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de UNIT CONTROL The product can be controlled using the remote control, a mobile app via Wi-Fi, the Google Assistant and Amazon Alexa. Before turning on the unit, open the rotating dampers on the indoor part of the product.
Page 14
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de Connecting a mobile device to the unit The application is available for download at App Store, Play Market or via the QR code. Blauberg Home – App Store Blauberg Home – Play Market To start controlling the product, first connect to it as a Wi-Fi access point with the name FAN: + 16 characters of the ID number indicated on the control board and on the unit casing.
Page 15
The sensor has a temperature measurement error of ±2 °C. Reheating for Freshpoint Eco 160-E models The product has a built-in electric heater that can be used to increase the supply air temperature.
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de TECHNICAL MAINTENANCE Maintenance of the unit means regular cleaning of the ventilator surfaces of dust and cleaning and replacement of the filters. To access the filters, remove the decorative panels from the work unit. Remove the filters.
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de Replacement of the remote control battery (if necessary). No response of the unit for pressing the remote control buttons indicates the need to replace the battery. The battery type is CR2025. Remove the holder with the battery from the lower part of the remote control.
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
Freshpoint eco 160(-e) (l055/l07/l1) www.blaubergventilatoren.de CERTIFICATE OF ACCEPTANCE Unit Type Decentralized Heat Recovery Unit Model Serial Number Manufacture Date Quality Inspector’s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.
Need help?
Do you have a question about the Freshpoint Eco 160 and is the answer not in the manual?
Questions and answers