We have a policy of continued product and quality development and improvement. Accordingly we reserve the right to amend the specification at any time. All errors and omissions excepted. Multiplex Boil3 user & installation guide v1-a...
Fitting the drain valve • Locating and fitting the boiler unit • Connecting the tubes • Calibration procedure • How the Multiplex Boil3 works • Connection summary • Spares list • Technical Data • Multiplex Boil3 user & installation guide v1-a...
Servicing and maintenance of this product must be carried out by persons having knowledge and practical experience of the appliance, in particular as far as safety and hygiene are concerned. The Multiplex Boil3 system contains no user serviceable parts and should only ever be serviced by the recommended service agent.
⚠ ⚠ For safety regulations the plug or means Do not use any water jet or steam near of disconnection must always be accessible this appliance. after installation. Multiplex Boil3 user & installation guide v1-a...
Each time the product is used you should flush a small amount of boiled water through before use. Typically this can be used to preheat your cup. If unused for extended periods then flush the product for a longer time. Multiplex Boil3 user & installation guide v1-a...
Ensuring that the filter system is set up correctly and replaced, as required, will reduce the frequency of descaling required. If you are regularly needing to descale the Multiplex Boil3 system then you either need to replace the filter more frequently or check the setup of the filter system.
Page 7
13. Lid fits flush with tank 14. Fully fasten tank lid ring 15. Lower lid & knob (d) and when fully fitted. clockwise. styrene insulation (e). Multiplex Boil3 user & installation guide v1-a...
Page 8
See 23. Wait 12 minutes for user manual for details. 22. Turn on water and unit to re-boil. flush through at least 5 litres. Should any taste persist repeat steps 22 & 23. Multiplex Boil3 user & installation guide v1-a...
Please follow the procedure below. ⚠ The water in the Multiplex Boil3 tank may be up to 98°C and as such represents a scalding risk if handled without due care. We recommend that the boiler is switched off before draining any stored water.
Page 10
7. Each time the product is used you should flush a small amount of boiled water through before use. Typically this can be used to preheat your cup. If unused for extended periods, then flush the product for a longer time. Multiplex Boil3 user & installation guide v1-a...
The Multiplex Boil3 system contains no user serviceable parts and should only ever be serviced by the recommended service agent. If your Multiplex Boil3 is not working satisfactorily, make the following checks before calling out the installer. Any one of these adjustments could restore the performance.
Page 13
Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance. The inner plastic tube MUST MUST be MUST MUST reconnected correctly afterwards. Multiplex Boil3 user & installation guide v1-a...
Page 14
Multiplex Boil3 working life and efficiency. No warranty applies to wear and tear expected to occur during the normal course of use, including without limitation, cosmetic rust, scratches, dents or comparable and reasonably expected losses or damages.
In the unlikely event that you should experience any defect in the materials or workmanship of your new Montpellier mixer within 5 years of purchase, the purchaser’s sole remedy shall be the replacement (at the manufacturer’s discretion) of all or any part of the product that is defective.
This tap has been 100% assembly tested; therefore you may expect a small residual amount of water to remain in the tap when delivered. Any water marks can be removed using the above care advice. Multiplex Boil3 user & installation guide v1-a...
This tap is designed to be installed in a worktop with a maximum thickness of 50mm. Ensure you have suitable domestic hot and cold water pressure before installing this product (see technical data for more information). Multiplex Boil3 user & installation guide v1-a...
110° rated hot water hose (from boiler output) 3/8” fibre seal Boiler Flexible boiled water output pipe Connecting tundish assembly Flexible drain pipe *Part supplied with boiler pack. ⚠ Do not switch on the boiler until instructed. Multiplex Boil3 user & installation guide v1-a...
12. Connect the cold water flexi hose (B1) to the cold water isolation valve (B5) using a section of 15mm pipe (B4) and compression nuts (B3) and olives (B2). Repeat the process to connect the domestic hot flexi hose (B6) to the domestic hot water supply. Multiplex Boil3 user & installation guide v1-a...
⚠ The installation should be periodically checked for damage. If the property is left unattended for a prolonged period we recommend isolating water supplies and switching Multiplex Boil3 user & installation guide v1-a...
Page 21
The installation order is as follows: Fit the mixertap or dispenser in (section 2.1.) if not already done so. • Fit the drain valve. • Fit the boiler. • Connect the tubes. • Commission / Calibrate • Multiplex Boil3 user & installation guide v1-a...
Page 22
Down loops in the hot hose (D1) are permitted as long as they are not lower than the drain level of the valve at any point. If they drop below this level the valve will not function correctly. Multiplex Boil3 user & installation guide v1-a...
Page 23
• The boiler plug must be accessible at all times to allow unimpeded service access, isolation and removal. The power wire should not pass through a hole in the cabinet smaller than the plug Multiplex Boil3 user & installation guide v1-a...
Page 24
To optimize the performance of the unit this length needs to be kept to a minimum. Fully insert the cold connection tube (blue) into the boiler inlet, connect the other end to the filter outlet. Multiplex Boil3 user & installation guide v1-a...
Page 25
1. Pull the lever forwards for approximately 1 minute or until water flows 4. The red light will come on when the 3. Turn the boiler on at the mains boiler is turned on. Multiplex Boil3 user & installation guide v1-a...
Page 26
Note: The drain/tundish valve does take time to fully drain the tap, so repeated draw offs can cause the tap to drip while heating back up. Once drained the tap will not drip. Multiplex Boil3 user & installation guide v1-a...
Page 28
2.5 bar 2.5 bar 2.5 bar Max. water pressure – 8.0 bar 8.0 bar 8.0 bar 8.0 bar Temperature range – 65 65 65 65 – – – – 98°C 98°C 98°C 98°C Multiplex Boil3 user & installation guide v1-a...