Item no. 14691-5-9970 · ENU · Change 207570 · Approved 2020-01-02 · Page 1 / 11
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
2
3
4
4
5
5
5
5
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
7
authorized technical staff.
8
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
10
following installation in the final product.
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
10
Keep the workplace clean and tidy. Untidiness in the work area
11
increases the risk of accidents.
11
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.3 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R4D450-AA04-05 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst R4D450-AA04-05

  • Page 1: Table Of Contents

    5.4 Disposal Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.3 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions R4D450-AA04-05 WARNING WARNING Live terminals and connections even with device Rotating device switched off Long hair and dangling items of clothing, jewelry and the like Electric shock can become entangled and be pulled into the device. Injuries can result.
  • Page 3: Intended Use

    Operating instructions R4D450-AA04-05 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions R4D450-AA04-05 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Accessory part: inlet ring 54478-2-4013 not included in scope of delivery Max. clearance for screw 10 mm Tightening torque 1.5 ± 0.2 Nm Cable diameter min. 6 mm, max. 12 mm, tightening torque 2 ± 0.15 Nm...
  • Page 5: Nominal Data

    Phase With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load Nominal voltage / VAC cycles. If you have special questions, consult ebm-papst for Wiring Δ support.
  • Page 6: Connection And Startup

    Operating instructions R4D450-AA04-05 4. CONNECTION AND STARTUP CAUTION Voltage The fan is a built-in component and has no disconnecting switch. 4.1 Mechanical connection → Only connect the fan to circuits that can be switched off with CAUTION an all-pole disconnection switch.
  • Page 7: Connection In Terminal Box

    Operating instructions R4D450-AA04-05 4.2.4 Variable frequency drive When routing the cable, make sure that the cable glands are located at the bottom. The cables must always be routed downward. Please use a variable frequency drive only after consultation with ebm- papst.
  • Page 8: Connection Diagram

    Operating instructions R4D450-AA04-05 4.4 Connection diagram Δ Delta connection Star connection = V1 = black = U1 = blue = W1 = red green yellow white Thermal overload protector Item no. 14691-5-9970 · ENU · Change 207570 · Approved 2020-01-02 · Page 8 / 11...
  • Page 9: Opening Additional Cable Glands

    Operating instructions R4D450-AA04-05 4.5 Opening additional cable glands NOTE Damage to the device from vibration A second cable gland opening can be made in the terminal box. Bearing damage, shorter service life WARNING → Low-vibration operation of the fan must be ensured over the In the event of a fault, the cable gland is energized entire speed control range.
  • Page 10: Maintenance, Malfunctions, Possible Causes And Remedies

    Operating instructions R4D450-AA04-05 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE In the event of further malfunctions, contact ebm-papst. CAUSES AND REMEDIES Do not perform any repairs on your device. Send the device to ebm- 5.1 Vibration testing papst for repair or replacement. Checking of fan for mechanical vibration based on ISO 14694.
  • Page 11: Safety Inspection

    ISO 14001 and rigorously implemented around the world on the basis of German standards. → Please contact ebm-papst for any other questions on disposal. Right from the development stage, ecological design, technical safety and health protection are fixed criteria.