USE AND MAINTENANCE INSTRUCTIONS
WOOD STOVE
Nadia
Noemi
Read instructions carefully before installation, use and maintenance
The instruction manual is an integral part of the product
Laminox S.r.l. reserves the right to change the characteristics and data reported in the following
document at any time and without warning in order to improve their products. This manual, therefore,
cannot be considered as a contract with third parties.
The updated manuals and drawings are available on the website www.laminox.com.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Idro Nadia and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LAMINOX Idro Nadia

  • Page 1 The instruction manual is an integral part of the product Laminox S.r.l. reserves the right to change the characteristics and data reported in the following document at any time and without warning in order to improve their products. This manual, therefore, cannot be considered as a contract with third parties.
  • Page 2 Dear Customer, thank you for choosing one of our products, which is a result of technological expertise and our continuous quest for superior products in terms of safety, reliability and performance. This manual contains all the information and helpful tips for using your product with maximum safety and efficiency. IMPORTANT INFORMATION This manual has been prepared by the manufacturer and is an integral and essential part of the product.
  • Page 3: Table Of Contents

    INSTALLATION ......................4 General notes........................4 Smoke discharge system ....................4 Smoke duct ........................4 Chimney of flue ....................... 5 Using an external fume duct .................... 6 Chimney pot ........................7 External air intake vent ....................8 Installation room ......................9 Minimum safety distances .....................
  • Page 4: Installation

    INSTALLATION General notes The heating system or appliance must be installed in order not to damage the building and other systems. The installer must strictly comply with standard UNI 10683:2022 and all other applicable local regulations. Smoke discharge system Every device must be connected to a fume discharge system, which ensures dispersion of combustion products into the atmosphere.
  • Page 5: Chimney Of Flue

    • They must be installed in such a way as to allow for normal thermal expansion • Along their entire length, they must have a diameter no less than that of the attachment of the appliance's evacuation duct • They must allow the recovery of soot and be inspectable •...
  • Page 6: Using An External Fume Duct

    WITH Ø 80 mm TYPE OF SYSTEM TUBE Minimum length Maximum length (with 3 90° curves) Maximum number of curves Tab.1 NOTE: load losses of a 90° curve can be equated with those of 1 metre of tube; the serviceable T-connection is to be considered as a 90°...
  • Page 7: Chimney Pot

    Inspection External air intake vent with non-lockable grid Fig. 5 Chimney pot The top of the chimney flue must be equipped with a device, called a chimney pot, which facilitates dispersion into the atmosphere of combustion products. The chimney pot must meet the following requirements: •...
  • Page 8: External Air Intake Vent

    Fig.8 External air intake vent The stove must have the air necessary to ensure smooth combustion operation and good environmental well-being. Make sure that the room where the stove is installed offers sufficient ventilation and install an air supply duct from the outside with the recommended minimum section of 100 cm². Ventilation openings are not required: •...
  • Page 9: Installation Room

    requirements set out in the paragraphs above. The adjacent room cannot be used as a garage, for storage of combustible material or for activities involving a risk of fire Installation room • Installing the device inside rooms at risk of fire is prohibited. •...
  • Page 10: Minimum Safety Distances

    1.8.5 Capacity of the floors of the installation room The floor of the installation room must have a capacity suitable for supporting the total weight of the appliance 1.9 Minimum safety distances The following figures show the minimum safety distances which must always be guaranteed. Corner installation (mm) Wall installation (mm) Fig.10...
  • Page 11: Flooring Protection

    1.10 Flooring protection In the event of valuable flooring or flooring that is sensitive to heat, moisture or is flammable, a floor protection must be used (i.e. sheet steel, marble or tile slabs). Whichever type of protection selected, it must protrude at least 300 mm from the front, at least 150 mm from the sides of the stove, must withstand the weight of the stove and have a thickness of at least 2 mm (Fig.
  • Page 12: Specifications And Technical Data

    SPECIFICATIONS AND TECHNICAL DATA Technical data Model Nadia Noemi Global thermal power 8,2 kW 8,2 kW Hourly consumption 1,9 kg/h 1,9 kg/h Rated thermal power 7,0 kW 7,0 kW Efficiency 85,4 % 85,4 % 10 Pa 10 Pa Recommended draft 120 mm 120 mm Smoke outlet diameter...
  • Page 13: Fuel

    3 FUEL General notes This stove is designed to burn only wood logs with the following characteristics Maximum length: < a 30 cm Maximum circumference 35 cm Humidity rate: < 20 % We recommend to use beech, olm or in any case class A1 wood in accordance with UNI EN ISO 17225-5 The wood should be stored in a dry and sheltered place.
  • Page 14: Use

    5 USE • All local regulations, including those relating to national and European regulations, must be observed when installing the unit. Improper installation or use of the device can result in forfeiture of the warranty. • Do not use the unit as an incinerator or in any other way other than that for which it was designed. •...
  • Page 15: Ignition

    Ignition Place the starter lever in the open position (fig 15) Position the air register to its maximum position (fig.16) and keep any butterfly valve located on the fume exhaust pipe open to the maximum position Place small wooden strips in the combustion chamber, place a solid or gel lighter or igniter on top of the strips and light with flame burners Leave the door closed for a couple of minutes or more (this depends on the temperature of the house and the flue).
  • Page 16: Ventilation (Only Suitable Models)

    Ventilation (only suitable models) In ventilated models, a fan can be activated which allows you to accelerate the diffusion of heat in the room or to heat another room via rear ducting 5.3.1 Control panel Using the control panel located at the rear of the stove it is possible to manually turn the ventilation on and off and adjust the speed of the fan ON/OFF FAN SPEED...
  • Page 17: Warning And Maintenance

    6 WARNING AND MAINTENANCE CAUTION: During operation, some parts of the stove (door, handle, ceramic pieces) can reach high temperatures, always use the glove supplied Remember to maintain the previously indicated safety distances. Therefore, be very careful, use the necessary precautions and always follow the instructions. If during operation any part of the stove or the outlet pipe leaks smoke, immediately turn off the stove and ventilate the room.
  • Page 18: Stove Inactivity

    Stove inactivity At the end of the season, perform the following operations: • Thoroughly clean the combustion chamber • Thoroughly clean the smoke exhaust system: contact a professional chimney sweep for this purpose. • Clean all dust, spider webs, etc. from the area behind the panels of the inner cladding once a year. Clean fans thoroughly.
  • Page 20 Laminox S.r.l. Zona Industriale Callarella, 261/263 – 62028 SARNANO (MC) Italy Tel. +39 0733.657.622 – Fax +39 0733.657.494 www.laminox.com e-mail: export@laminox.com Nadia-rev06/2024 EN...