Table of Contents NOTE: These instructions include information on how to install multiple 7 Series refrigeration units. For information on dimensions, specifi cations, and installation of single units, please refer to the installation guide included with the appliances. Parts Included ____________________________________________________________________________________________2 Tools Needed ____________________________________________________________________________________________2 Install Confi gurations &...
Install Confi gurations & Clearances Recommended Confi gurations Recomended Configurations Single Unit Stacked Unit Install Side by Side Unit Install Install (All LH or RH Units) (Opposing LH & RH Units) Recommended Clearances Recomended Clearances 4.5" 9" Unit Size Dim. A 9.75”...
Cutout Dimensions Electric Outlet Location There must be a separate 15 amp outlet for each unit installed 1 5 - 1 / 2 ” ( 3 9 . 4 c 4 - 1 / 4 ” ( 1 0 . 8 c l e v e l i n d i m e n s i o n...
Specifi cations Refer to Installation Guides included with unit for individual dimensions. Below is a common install chart for reference. Cabinet Cutout Height Cabinet Cutout Depth Size Combination Cabinet Cutout Width (same for all) (same for all) 18” W / 24”W Models 42”...
Anti-tip Location WARNING Proper placement of anti tip bracket is an important function of the installation process. The installer shall check and make sure that the unit is getting engaged with the bracket when they try to tilt the unit from top similar to the unit tipping condition. Anti-tip Bracket The anti-tip bracket has several holes set up on a grid in order to better locate a wall stud.
Preparing Units for Installation Before removing units from pallet, remove / replace the side trim from each unit if needed, install center trim brackets and connection heater. Make sure units are unplugged and powered off . Look closely at the trim already installed on the unit. REMOVE TRIM A INSTALL TRIM B If the trim resembles that in Trim A, it will need to be...
Page 8
Preparing Units for Installation 1. Fasten heater (Item #1) to the three mounting holes on top of the right hand unit using the #8-18 x 1/2” fasteners (Item #7) provided. 2. Plug heater terminal into right hand unit using the plug located next to the unit on/off switch.
Installation WARNING TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
Page 10
Installation 6. If unit leveling feet were used, lower units back onto rollers. Plug in electrical supply and roll connected units into cabinet cutout. Units must be plugged into separate electric outlets. Connect water supply to each unit. 7. Lift units to desired height using 5/16” socket and hand ratchet. DO NOT USE A DRILL-(refer to lift pattern diagram below to ensure that units are gradually lifted together.) **IMPORTANT** - Only make 4 turns at a time with the hand ratchet**.
Page 11
Installation 8. Remove plastic fi lm from center trim before installing. Install center connecting trim (Item #3) in between the two units by pressing it in. Trim should be even with the top of the units. If needed, tap connecting trim gently into place with rubber mallet.
Page 12
Remove screws fastening individual kickplates on units. Save screws to be used when installing custom kickplate. Place custom kickplate across bottom of both units and fasten using the mounting holes for the individual kickplates. Viking Range, LLC 111 Front Street...
Need help?
Do you have a question about the CKVBI and is the answer not in the manual?
Questions and answers