Page 2
4G Gate Opener RTU5025 Preface Thanks for choosing BLIIoT 4G Gate Opener. These operating instructions contain all the information you need for operation of RTU5025. Copyright This user manual is owned by Shenzhen Beilai Technology Co., Ltd. No one is authorized to copy, distribute or forward any part of this document without written approval of Shenzhen Beilai Technology.
4G Gate Opener RTU5025 Table of Contents 1 Introduction ..............................5 1.1 Features ..............................5 1.2 Specifications .............................5 1.3 Dimension ............................6 1.4 Packing List ............................7 1.5 Applications ............................7 2 Safety Directions ............................7 3 Diagram ..............................8 4 Typical Wiring ............................9 5 Setting by PC ............................
Page 4
4G Gate Opener RTU5025 6.5.1 Arm and Disarm ........................17 6.5.2 Define the DIN1/ DIN2 Type ....................17 6.5.3 Modify the Alert SMS Content When Inputs Alarm .............18 6.5.4 Inquiry the NC/NO Type and Alert SMS Content of DIN1(2) ..........18 6.5.5 Digital Alarm Conditions ......................18 6.6 Others ..............................18...
4G Gate Opener RTU5025 1 Introduction The RTU5025 gate opener can be used for remote control swing or sliding gates and doors or switching devices with authorized access management(Caller-ID), it is widely used in door access, gate control, remote switching, or car parking systems. The RTU5025 can be used in places which require to turn ON/OFF your system, machines, equipment remotely with a FREE phone call from your mobile or fixed line telephone.
4G Gate Opener RTU5025 DC Power supply 9~36VDC/2A Power consumption 12V input Max. 50mA/Average 25mA SIM Card Supporting 3V SIM Card Antenna 50 Ω SMA Antenna interface Temperature range -20~+60 °C Humidity range Relative humidity 90% Backup battery 3.7V/900mAH Dimension...
4G Gate Opener RTU5025 Interference All wireless equipment might interfere network signals of Gate Opener and influence its performance. Avoid Use at Gas Station Do not use Gate Opener at a gas station. Power off Gate Opener when it near fuels or chemicals.
4G Gate Opener RTU5025 INDICATORS Power ON: DC power supply is ON. Alarm Flash quickly: Alarm occurrence. Relay ON: Relay closed(ON). Flash per 1 second(quickly): Registering to cellular network. Flash per 2 seconds: Normal status. OFF: Can’t connect to SIM card or unregistered to the cellular network Connection Terminals Power supply input, Positive wire(Red).
Open the unit's back cover and insert the SIM card. Connect the unit's power supply. Send SMS command pwdTELphone number of the RTU5025# to set the time. Do not include the "", for example:1234TEL001911#, this step must be completed. Connect the unit to the computer using the USB cable.
Save Settings: Save the basic parameter settings to the RTU5025. Import profile: Import .xls profile, this can use for a number of RTU5025 with similar settings. Export profile: Export the parameter settings as .xls format to the PC, under the /configuration folder.
Export .csv: Export the authorized number list (.csv format) to the PC, under the /configuration folder. All Always: Select all the numbers as “Always can call in to the RTU5025 for access control”. Delete all: Delete all the numbers on the list, after click this button, then click “Save” button, all the numbers on the RTU5025 will be deleted.
The default Password is 1234. You can set the RTU5025 by APP or SMS commands using your phone. It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it, we also use a Password that makes it impossible for others who doesn't know it to access the system by chance, and all the actions will be recorded.
4G Gate Opener RTU5025 and add the authorized numbers. If you cannot call to control the RTU5025 or cannot send or receive any SMS message from it. please try to add + in front of the country code or the phone numbers.
4G Gate Opener RTU5025 1234AL0002#0050# E.g.: to inquiry the 2 to the 50 users,RTU5025 return several SMS with the numbers list(10 numbers on each SMS). 6.3.4 Delete the Authorized User’s Number You can overwrite this position with another number pwdA serial number ## E.g.:...
DIN2 for motion/smoke or other sensors to protect your assets, SMS alert send to the 1 position number when there have any alarm occurrence. On alarming situation, after alert SMS send out, RTU5025 will call the 1 number in turn until somebody pick up the phone call, and will stop to calling after the 6 number.
6.5.5 Digital Alarm Conditions The DIN1/DIN2 will trigger an alarm only under the below two conditions RTU5025 under the Armed Mode 10mins after the last call in from the authorized numbers. (10mins default, users can modify the ...
4G Gate Opener RTU5025 6.6.2 Self-check Auto Report SMS to the 1 Number unit: hour pwdT#xxx# xxx=000~999 xxx=000, default, no self-check auto report. Auto report SMS including: Arm/Disarm Status; DIN1/2 status; Relay status; GSM signal value(full is 31, cellular signal weak if lower than 14) AC/DC power supply status.
The CMS software can be server based($500~$800usd) or web based(~12,000usd), due to the high cost, this function for customer who purchased more than 100pcs RTU5025 only, for small project we suggest client using PC software to configure or read historical data via USB cable or SMS.
6.7.3 CMS Server IP Address(or DNS/DDNS) and Server Port pwdIPserver IP address or DNS/DDNS name*server port# E.g.: 1234IP175.164.49.20*4006# When data connection failure or parameters setting wrong, RTU5025 send SMS to the 1 user: GPRS connect failure. 6.7.4 Data Upload to CMS Interval Time...
4G Gate Opener RTU5025 Take the BLIIoT V2.0 platform as an example (1) Server address is mqtt.dtuip.com (2) Server port is 1883 nterval (3) Heartbeat i set to 20 seconds (4) MQTT Client ID: The client identifier used in the MQTT connection message. The server uses the client identifier to identify the client, and each client connecting to the server has a unique client identifier.
Need help?
Do you have a question about the RTU5025 and is the answer not in the manual?