S3 OMNI Replacement PCB
Background
The GLXS3OMNIPCB is a replacement main printed circuit board (PCB) for the AQRS340OMNI and AQRS325OMNI chlorinator/automation controls. The
GLXS3OMNIPCB replaces the original PCB in these products. Note that all settings will be lost after this replacement and the AQR S3 Omni
reconfiguration and setup. If possible, record the existing settings before replacement. Refer to the AQR S3 Omni Installation and Operation manuals for
configurations and settings information.
To replace the board, follow the replacement procedure below. Please verify that the replacement PCB matches the original board before you begin.
Contents of Kit
•
1 GLXS3PCB main circuit board
•
3 Replacement terminal blocks (if needed)
•
1 Input power connector cable (if needed)
•
6 Phillips head screws (if needed)
•
2 Replacement fuses (if needed)
1. Front Panel Removal
DANGER of Death, Injury or Property Damage if pro-
cedure not followed. Dead front panel removal is re-
quired for this installation. Power to the AQR S3 MUST
be shut off before the dead front panel is removed.
2. Remove Wiring Connections
Remove all of the wiring connections to the existing PCB
as shown in the diagram.
GLXS3OMNIPCB
WARNING: Disconnect all AC power at the main breaker before at-
tempting to replace the PCB. Use a voltmeter to verify that the main
supply input has been entirely removed from the control. Use ap-
propriate energy lock-out procedures to be certain nobody restores
power during the following procedure.
Remove
three screws
pH Sensor (BNC)
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Pull the display away from the panel
by grasping it with your hand (no tools
required). Then, remove the 3 screws
and pull the plastic deadfront panel
away from the enclosure.
ORP Sensor
RS-485 for VSPs, Smart Relays
(BNC)
and additional chlorination
Valve Actuators
Controller
Heater 2
Solar Temperature Sensor
Data Cable
Power Cable
092776 RevA
will require
®
Need help?
Do you have a question about the S3 OMNI and is the answer not in the manual?
Questions and answers