For factory installed blower kits refer to page 2 of this instruction sheet for thermostat bulb relocation.
DISCONNECTING WALL MOUNTED HEATER
Wall mounted heater must be disconnected from gas supply and removed
from wall before installing fan accessory. Contact a qualified service person
to do this. Follow all codes.
REMOVING PANEL FROM BACK OF HEATER
If your heater has a knock-out panel, insert a flat screwdriver into the hole
in the panel and remove panel to the outside of the heater (see Figure 1).
If your heater has an installed panel, remove panel with a Phillips head
screwdriver (see Figure 1).
ATTACHING FAN/BLOWER ASSEMBLY
1. Attach fan/blower to the rear panel of the heater using the four screws
provided (see Figure 2).
2. Remove front panel assembly from heater (see your heater owner's manual).
3. Attach thermostat switch to top of fan/blower using 2 screws (see Figure 3).
Replace front panel assembly
Fan/Blower
Assembly
View from
Front of Heater
FAN OPERATION
To operate in Manual mode, turn on/off switch to the ON position. To operate
in Automatic mode turn AUTO/O/MAN to the desired position, Man position will
remain constantly on. Auto position will be controlled by the sensor on fan blower
unit. To stop the operation, turn unit switch to the O position (see Figure 2).
ELECTRICAL CONNECTION
Do not use this fan/blower if any part of it has been
under water. Immediately call a qualified service tech-
nician to inspect the fan/blower and replace any part
of the electrical system which has been under water.
This fan/blower accessory must be grounded. This unit comes with a 3-prong
grounding plug for your protection against electrical shock. Use standard, 3
holes, grounded outlet. If an extension cord is needed it must have a 3 prong
plug and a 3 hole receptacle. An undersized cord will cause a drop in live
voltage and could result in loss of power and overheating.
INSTALLING FAN/BLOWER ACCESSORY
MODEL MGB100
Panel
Figure 1
On/Off Switch
Auto/O/Man
Switch
Figure 2
Thermostat
Switch
Figure 3
GROUNDING INSTRUCTIONS
This fan/blower is for use on 120 volts. The cord has a plug as shown at
A in Figure 4. An adapter as shown at C is available for connecting three-
blade grounding-type plugs to two-slot receptacles. The green grounding
lug extending from the adapter must be connected to a permanent ground
such as a properly grounded outlet box. The adapter should not be used if
a three-slot grounded receptacle is available.
Grounding Pin
C
Adapter
Grounding Means
FAN OPERATION
To operate the manual unit, turn ON/OFF switch to the ON position. To op-
erate the Automatic unit, turn AUTO/O/MAN switch to the desired position.
MAN position will remain constantly on. AUTO position will be controlled by
the sensor on the fan blower unit. The sensor will be activated when the
temperature of the sensor head reaches the set point of the switch after the
heater is started. To stop the operation, turn the switch to the O position.
ELECTRICAL WIRING
Any electrical re-wiring of this appliance must be done by a qualified elec-
trician. This wiring must be done in accordance with local codes and/or in
Canada with the current CSA C22.1 Canadian Electrical Code, and for US
installations, the National Electrical Code ANSI/NFPA NO 70.
WARNING: If repairing or replacing any electrical
component or wiring, the original wire routing, color
coding and securing locations must be followed.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
and dangerous operation.
WARNING: Never attempt to service fan/blower while
it is plugged in, operating, or hot. Burns and electrical
shock could result. Only a qualified service person
should service or repair fan/blower.
Verify proper operation after servicing. If any of the original wire as supplied
with the appliance must be replaced, it must be replaced with a wire of at
least a 105º C temperature rating.
Switch
Black
Green
White
A
Cover of
Grounded
B
Outlet Box
Metal Screw
Figure 4
Thermostat Switch
AUTO
O
MAN
Motor
Figure 5

Advertisement

loading
Need help?

Need help?

Do you have a question about the MGB100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Procom MGB100

  • Page 1 INSTALLING FAN/BLOWER ACCESSORY MODEL MGB100 For factory installed blower kits refer to page 2 of this instruction sheet for thermostat bulb relocation. DISCONNECTING WALL MOUNTED HEATER GROUNDING INSTRUCTIONS Wall mounted heater must be disconnected from gas supply and removed This fan/blower is for use on 120 volts. The cord has a plug as shown at from wall before installing fan accessory.
  • Page 2 Bulb Clip Thermostat Sensing Bulb Shipping Thermostat Location Sensing Bulb Bulb Clip Thermostat Sensing Bulb Relocation Position Figure 7 - Moving Thermostat Sensing Bulb Infrared Heaters Only ProCom Heating, Inc. Bowling Green, KY 42101 200285-04 www.usaprocom.com Rev. B 1-866-573-0674 03/17...