Advertisement

Quick Links

LDC500/750/1000WPR
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LDC500WPR and is the answer not in the manual?

Questions and answers

Summary of Contents for AURORA SIGNAGE LDC500WPR

  • Page 1 LDC500/750/1000WPR User Manual...
  • Page 2 Aurora Signage 2022 all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. Aurora logo and identifying product names and numbers herein are trademarks of Aurora Signage. Copyright protection claimed includes all forms and matters of copyrightable materials and in- formation now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    Maintenance steps 12-17 Installation type 1: Wall-mounted directly 18-19 Installation type 2: Totally front installation 20-24 Installation type 3: Totally Rear installation 25-28 Optional Components and Accessories Package and transportation Technical Specifications Optional components & Accessories Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 4: General Information

    In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not discard the shipping carton in the trash. Please recycle whenever possible. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 5: Safety Guidelines

    ALWAYS disconnect panel from main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 6 CAUTION: It should be installed from top to bottom and disassembled from bottom to top when hoisting. CAUTION: Test panel for 2-hours per week, if not used regularly or for an extended period. CAUTION: Cases used to transport panel must me properly waterproofed for transportation. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 7: Maintenance Guidelines

    / rear), limit or remove any unit exposed to moisture, condensation, or humidity, and consider using air conditioning where available. 15. When not in use, store LDC500/750/100WPRFP LED Video Panels in a dry, well ventilated facility. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 8: Panel Overview

    PANEL OVERVIEW Dimension: 500x750x77mm/ 500x1000x77mm/ 500x500x77mm Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 9 PANEL OVERVIEW Cable Management Tray Position Pin Module Handle Safety Rope Control Box Module Lock Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 10 PANEL OVERVIEW Input Power Cable & Input Signal Cable Power Supply HUB Card Receiving Card Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 11: The List Of Tool

    3.9mm and 2.9 mm Connecting Plate for both side cabinets installation Screw for the cabinet left and M10*52 right fixed Screw for the cabinet front and M10*75 back fixed Hex wrench for connection plate screws, front installation. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 12: Maintenance Steps

    MAINTENANCE STEPS 1. Front Maintenance A. Module Maintenance ① There is 4 lock holes on each module, located at 4 directions; and different pixel pitch is of different locations; please refer above pictures. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 13 90 degree to the left, to open the lock. ③ There is a safety rope to catch each module, unhook the safety rope. Please do the same way to take other modules out. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 14 2 screws; another one on the bottom, Total 8 screws; ③ Then please catch the power box up and down, and remove the power box. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 15 2) Release the 4 locks of each module by T- type Allen wrench 3) Unlock the safety rope 4) Catch the handle of the module 5) Push the module forward 6) Take the module out diagonally Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 16 1) There is two buckles on the power box, one 2) Open these two buckles. is located at the top, another one is located at the bottom. 3) Then you can do the maintenance for the power supply, receiving cards, HUB cards, etc. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 17: Installation Type 1: Wall-Mounted Directly

    ⚫ Steps of installation 1) Install connecting plate 1)Drill the hole 2)Locate plate with screw 3)Fixed the screw 4)Complete the screws 5)Fix the cabinet on top 6)Fix the cabinet on bottom 7) Tighten the screws 8) Finish installation Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 18 12) Lock the module 13) Finish install the modules ⚫ After installation 1.Check that each corner is secure, tap the module to ensure the smoothness of the screen, to avoid bad installation caused by not bright. 2.Debugging software Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 19: Installation Type 2: Totally Front Installation

    1. Install the steel structure, make sure the welding is correct according to the drawing, and spray paint. 2. Check the steel structure, make sure it is horizontal and vertical 1) Take off the corner modules and put cabinet on the first floor; put cabinets together. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 20 3) Fix the screw with Hex Wrench M8 4) Connect two cabinets together with screws from side 5) Put through the screws 6) Fix the nuts, tighten cabinets together 7) Put cabinet on top, located the position with two pins. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 21 9) Lock the screw to the connection plate with hex wrench M8. 10) Lock two cabinets together with screw 11) Tighten screw with nut 12) Finish installation of 4 cabinets. 13) Take cables out from the bottom of cabinet Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 22 15) Connect cables together 16) lock the cable cover. 17) Connect the plates and screws for side of the screen. 18) Fix the connecting plates from the left side. 19) Fix the screws for the side plates. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 23 20) Lock it together tightly. 21) Put the module back 22) Put the safety rope. 23) Install modules onto the cabinet. 24) Lock the module with T-type Allen Wrench. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 24: Installation Type 3: Totally Rear Installation

    3) Lock the connecting plate to the cabinet with M10*75 4) Lock two cabinets onto the steel square pipe. screw from back. 5) Connect left and right cabinets with screw and nut. 6) Put the screw through the cabinets. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 25 8) Fix two cabinets together with top and down screws. 9) Put cabinet on top of the first row. 10) Locate the top cabinet with position pins. 11) Put screws through the connection plate to the cabinet. 12) Fix the screw with Hex wrench. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 26 13) Fix all screws to the connecting plate 14) One connecting plate for 4 cabinets. 15) Put the cables through the cabinets 16) Connect cables together. 17) Put cables back to the cover. 18) Lock the cover and finish installation. Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 27 19) Connecting plate for side screen. 20) Put the connecting plates 21) Lock the connecting plate with screws 22) Finish the installation . Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 28: Package And Transportation

    Package and transportation A.Package B.Transportation Some reference data for loading(Suppose the space is fully utilised) Weight Total Panels Total Wooden Name Size Cases(Qty) (GW) (960*960mm/pcs) Wooden case 1.09*0.97*0.68m 163KG 8pcs Aurora Signage • ADELAIDE, AUSTRALIA...
  • Page 29: Technical Specifications

    Cabinet Weight(KG) 4000-4500 6000-7000 6000-7000 Brightness(Nits) 3,840 3,840 3,840 Refreshment(Hz) ≥ 15 ≥ 15 ≥ 15 Grey Scale(Bit) Max Power Consumption(W/SQM) Ave Power Consumption(W/SQM) Front/Rear Front/Rear Front/Rear Maintenance type IP66/IP66 IP66/IP66 IP66/IP66 Protecting level CE,FCC,ETL,EMC,CB,ROHS Certificate Aurora Signage • ADELAIDE, AUSTRALIA...

This manual is also suitable for:

Ldc750wprLdc1000wpr

Table of Contents