INTRODUCTION • MANUAL USE MODES THE INSTALLATION MUST BE CARRIED OUT BY AUTHORIZED AND SKILLED PERSONNEL ONLY. ARAG IS NOT RESPONSIBLE FOR ANY INSTALLATION CARRIED OUT BY UNAUTHORIZED OR UNSKILLED PERSONNEL. • RESPONSIBILITY It is the responsibility of the installer to perform the installation "in a workmanlike manner" in order to ensure proper operation of the system. ARAG recommends using its components to install control systems.
INSTALLATION PACKAGE CONTENT The package includes: Transportable tank filling system with threaded coupling The package does not include: Power supply Fig. 1 INSTALLATION The tank filling system must be connected by means of suitable fittings (2" F threaded fitting with hose tail) to a pump, which will supply the liquid to be poured into the tank.
INSTALLATION Hydraulic connections Avoid bottlenecks or twists before the fittings and on pipes. Do not use the tank filling system at pressure values higher than the ones indicated in the technical specifications. For the connections, use pipes and fittings duly dimensioned for the system operating pressure. WARNING: For the implementation on already operating systems, it is necessary to follow all safety rules described herein.
INSTALLATION 2.4.1 Power supply connection Connect the power supply connector to the relevant counterpart (not supplied) as shown in Fig. 6 Fig. 6 WARNING: To avoid short circuits, do not connect the power cables to battery before the installation is completed. Before powering up the filling system, make sure the battery voltage is as specified (12 Vdc).
PRELIMINARY SETUP FOR USE / PROGRAMMING PROGRAMMING Tests and checks before setting Before setup, check: • that all components are correctly installed; • the correct connection to the power source; • the component connection. Failure to correctly connect system components or to use specified components might damage the device or its components. Using the keys RESET RESET...
PRELIMINARY SETUP FOR USE / PROGRAMMING 3.2.1.1 Function odE It is possible to set 3 different operating modes: MODE 0 = Tank filling count with valve control command (0 ÷ 9999 EU: I [default setting] - US: gal) MODE 1 = Flowrate display MODE 2 = Tank filling count with valve control command (0 ÷...
PRELIMINARY SETUP FOR USE / PROGRAMMING 3.2.1.5 “ ” valve actuation time This parameter allows setting the time that the valve installed on the system takes to complete the closing operation; by setting this data, the flowmeter will be able to anticipate the exact moment at which to start the closing operation, preventing more product from entering when the set value is reached. = 0 ÷...
PRELIMINARY SETUP FOR USE / PROGRAMMING 3.3.1 Flowmeter constant setting 1) After performing the start-up procedure indicated in paragraph 3.1, the device switches to the display of the currently set flowmeter constant value alternating with CoSt the “ ” indication. 2) To change the figure, hold down the keys simultaneously until the screen “...
While the system is in use, the flowmeter sends pulses to the computer, which, based on the previously set constant value, will indicate the instant flowrate. An LED on the connector housing indicates the status of the device ( Fig. 12 LED off: the device is not powered.
4.1.3 Operation of Mode 0 - Mode 2 1) After start-up the amount of fluid to be poured into the tank is displayed. Strt 2) To start the filling procedure, keep key pressed until the message “ ” appears; the value corresponding to the total amount of fluid poured into the tank is displayed in real time.
4.2.2 Resetting the counter of the liquid filled in the tank 1) Access the display of the total liquid filled in the tank ( 4.1.2 2) To reset the total amount of liquid filled in the tank to zero, press and hold the RESET key until the message “...
MAINTENANCE / DIAGNOSTICS / REPAIRS MAINTENANCE / DIAGNOSTICS / REPAIRS Precautions for maintenance operations and for cleaning the external parts • DISCONNECT THE POWER CABLES. • WEAR SUITABLE PERSONAL PROTECTION EQUIPMENT, OVERALLS, GLOVES AND FACE MASK. • DO NOT CARRY OUT ANY OPERATION ON THE SYSTEM IF INDOORS OR IN POORLY VENTILATED AREAS. •...
TECHNICAL DATA TECHNICAL DATA ELECTRICAL FEATURES • Power supply voltage 11 ÷ 14.5 Vdc • Maximum absorption 3.3 A • Liquid minimum conductivity 50 μS/cm • Valve activation time 2.3 s. ENVIRONMENTAL FEATURES • Operating temperature 0 °C ÷ 60 °C / +32 °F ÷ +140 °F •...
WARRANTY / DISPOSAL GUARANTEE TERMS 1. ARAG s.r.l. guarantees this apparatus for a period of 360 days (1 year) from the date of sale to the client user (date of the goods delivery note). The components of the apparatus, that in the unappealable opinion of ARAG are faulty due to an original defect in the material or produc- tion process, will be repaired or replaced free of charge at the nearest Assistance Center operating at the moment the request for interven- tion is made.
Page 18
Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the Internet address www.aragnet.com Via Palladio, 5/A 42048 RUBIERA (Reggio Emilia) - ITALY Tel. +39 0522 622011 Fax +39 0522 628944 www.aragnet.com info@aragnet.com...