Summary of Contents for Brinsea OVA-EASY 190 ADVANCE

  • Page 1: Table Of Contents

    MJ192 GB Issue 02 OVA-EASY 190 and 380 ADVANCE User Instructions Contents Section Subject Page Introduction Unpacking Location and Installation Quick Reference Digital Control System Storage of eggs Temperature Humidity and Ventilation Egg Turning Egg Setting Hatching Cleaning up Troubleshooting Servicing and Calibration Specifications...
  • Page 2: Introduction

    MJ192 GB Issue 02 1 Introduction These instructions detail the operation of your new 190 or 380 egg Digital Cabinet Incubator with programmable automatic egg turning system. Please read these instructions carefully before setting up your machine to achieve best results and keep these instructions safe for future reference.
  • Page 3: Unpacking

    2 year guarantee. Go to www.Brinsea.co.uk and register as a free member of the Brinsea Email Group to receive the latest news and information such as advance notice about new products, special offers, exclusive competitions and much more.
  • Page 4 MJ192 GB Issue 02 MAIN MENU – QUICK REFERENCE 37.5C TEMP INCUBATION TEMPERATURE. RANGE 20.0 – 40.0°C (68.0 – 104.0°F). OK   OK - + DEFAULT 37.5°C (99.5°F). RELATIVE HUMIDITY. RH 20% RANGE 20% – 80%. DEFAULT 20%. OK   EX ONLY ONLY FOR EX VERSION WITH ADVANCE HUMIDITY PUMP –...
  • Page 5: Digital Control System

    The asterisk "*" adjacent to the relative humidity display is only on when the pump control output is on (see section 8) and is only applicable when using the optional Brinsea Advance Humidity Management Module. If automatic turning is switched off "=" is shown in the corner of the display.
  • Page 6 MJ192 GB Issue 02 HIGH TEMPERATURE ALARM DISPLAY – If the measured temperature goes up by more than the figure in the ALARM HI screen, the alarm will sound immediately and “+T” will be displayed. Press OK to silence the alarm for 30 minutes.
  • Page 7: Storage Of Eggs

    MJ192 GB Issue 02 TURN SYSTEM FAULT ALARM - If the shelves become jammed by debris or incorrectly loaded trays the motor is switched off and an alarm sounds. The display shows "FAULT". Automatic turning is also temporarily set to off (0) in the Main Menu to prevent the turn restarting. Always check trays are loaded to the back of each shelf as damage may occur if the shelves are jammed by trays placed too far forward.
  • Page 8: Humidity And Ventilation

    MJ192 GB Issue 02 Recommended temperatures: Typical incubation period: 37.4 – 37.6°C 99.3 – 99.6°F Hens 21 days 37.6 – 37.8°C Pheasant 99.6 - 100°F 23-27 days 37.6 – 37.8°C Quail 99.6 - 100°F 16-23 days 37.4 – 37.6°C 99.3 – 99.6°F Ducks 28 days 37.4 –...
  • Page 9 MJ192 GB Issue 02 Typical ideal weight losses for species groups: Poultry Waterfowl Egg weight loss chart Ideal weight (grams) Measured weight (grams) Incubation period (days) Of the two methods given above the most reliable is egg weight method and is recommended – particularly where poor hatch rates are experienced or if eggs of high value are being incubated.
  • Page 10: Egg Turning

    Resist the temptation to open the door frequently – leave for at least 6 hours between inspections. The Brinsea Advance Humidity Pump is available as an option on the Ova-Easy Advance incubators. The incubator digital control system not only reads the humidity in the incubator but it provides a control signal to operate the water pump and accurately maintain the humidity level at the desired level.
  • Page 11: Egg Setting

    MJ192 GB Issue 02 STOPPING A TURN TO LOAD THE SHELVES (OR USE ALL SHELVES FOR HATCHING) Press any button to stop a turn. This is useful to stop the shelves once they are level for loading trays and for when the whole incubator is to be used for hatching eggs.
  • Page 12: Cleaning Up

    Poor hatching results are frustrating and can be caused by a large number of factors. The most common are given below. Brinsea Products will not be held responsible for loss of eggs or chicks under any circumstances. A wealth of advice and information is available on our website:- www.brinsea.com 13.2...
  • Page 13 MJ192 GB Issue 02 1) Clear when candled - probably infertile (or very early death) when candled at 8 days 2) Fertile with red blood vessels - after 8 days 3) Red or black staining - early death when candled at 8 days 4) Embryo with red blood ‘ring’...
  • Page 14: Servicing And Calibration

    OK button. Check temperature calibration after resetting to defaults. 14.3 If the problem persists contact your distributor or Brinsea Products Service Dept. 14.4 The functional parts of the Ova-Easy Advance incubators are modular and parts are available and are readily exchanged by a suitably qualified person equipped with basic tools.
  • Page 15 WITH NO WATER IN THE EVAPORATING TRAY. RHC 7S RH CYCLE HUMIDITY PUMP CYCLE TIME. ONLY APPLICABLE WHEN USED OK   OK - + WITH THE BRINSEA ADVANCE HUMIDITY PUMP. AMBIENT TEMPERATURE T 20.0C AMBIENT COMPENSATION. AMBIENT TEMPERATURE USED IN OK  ...
  • Page 16: Specifications

    380 Advance, Incubator only 27Kg Power Consumption: Maximum 200 Watts (typical average) 100 Watts Electrical Supply: 230v 50Hz or 110V 60Hz (as ordered) Brinsea Products Ltd, Station Road, Sandford, N. Somerset, BS25 5RA, England Tel 0845 226 0120, Fax 01934 820250, email sales@brinsea.co.uk...