AEG AC2000 N1 Operating Instructions Manual
AEG AC2000 N1 Operating Instructions Manual

AEG AC2000 N1 Operating Instructions Manual

Switching power supply
Table of Contents

Advertisement

Quick Links

Switching
power supply
Operating instructions
AEG Power Solutions GmbH, Warstein-Belecke
Department:
R&D
Revision:
03
Editor:
27.05.2024 / Huynh
Checked:
27.05.2024 / Gottschlich
Document Nr.
80001533 EFE, en
AC2000 N1
AC3000 N1
DC2000 N1
DC3000 N1
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC2000 N1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AEG AC2000 N1

  • Page 1 Switching AC2000 N1 AC3000 N1 DC2000 N1 DC3000 N1 power supply Operating instructions AEG Power Solutions GmbH, Warstein-Belecke Department: R&D Revision: Editor: 27.05.2024 / Huynh Checked: 27.05.2024 / Gottschlich Document Nr. 80001533 EFE, en...
  • Page 2 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Revision Status Change Date Name First edition 14.05.2024 Huynh Update mechanical drawing 21.05.2024 Huynh CN: 500000001884 Additions to technical data 27.05.2024 Huynh CN: 500000001947 ...
  • Page 3: Table Of Contents

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions TABLE OF CONTENTS TABLE OF CONTENTS ..............3   SAFETY REGULATIONS ............5     Information symbols ..............5     Appropriate use ............... 5  ...
  • Page 4 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Safe operation/safe functioning ..........29     Normal function ..............29     6.2.1 Electrical mode of operation ..........29     6.2.2 Input ..................
  • Page 5: Safety Regulations

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions SAFETY REGULATIONS This chapter provides guidance on all safety-related issues. All safety measures, safety equipment and residual hazards of the appliance are described. Read this chapter carefully before carrying out any work on the appliance.
  • Page 6: Obligations Of The Operator

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Obligations of the operator The safety of personnel as well as the safety, function and availability of the system depend on compliance with the safety instructions. The safety instructions must always be observed.
  • Page 7 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Duties of the specialist personnel Observe the following safety instructions. When working in and on electrical installations, fixed rules apply to prevent electrical accidents. These rules are summarized in the five safety rules.
  • Page 8: Duties Of The Transport Personnel

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Duties of the transport personnel Observe the following safety instructions during transportation. Read the operating instructions. Memorize the safety regulations. Observe the regulations: ...
  • Page 9: Identification

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions IDENTIFICATION Product brand and type designation Type designation: Part number: Input Output Output voltage: voltage: current: AC2000 N1 E230 G24/65 BWrg-Cü 10005614 230 V AC...
  • Page 10: Product Description

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions PRODUCT DESCRIPTION General functions and area of application, intended use Illustration 2: Front view with terminal cover removed. The AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 switched-...
  • Page 11 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions The device is supplied as a ready-to-connect unit. The connections are accessible from the front for easy maintenance. The operating and display elements are built into the front of the device.
  • Page 12: Overview Of The Front Panel Elements

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Overview of the front panel elements Pluggable terminal X1 Mains input plug. The polarity in brackets applies to devices in the DC series.
  • Page 13 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Remote signal connector X11 Ground external setpoint specification External voltage setpoint specification (section 6.3.3) External current setpoint specification (section 6.3.3) +7.5 V internal reference voltage (section 6.3.3)
  • Page 14 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions LED H1 (Supply) Display: Mains voltage supply within the tolerance range. LED H2 (Operation) Display: Power output. Switch S3 (On/Off) Switch the device on/off.
  • Page 15: Technical Data

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions TECHNICAL DATA General technical data Inrush current ........Current consumption input current Required mains fuse gL ....16 A Input fuse ......... Internal HRC fuse Characteristic curve ......
  • Page 16 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Monitoring Basic settings ............Description of the monitoring: ( section 6) - Mains undervoltage with switch-off, self- acknowledging - Mains overvoltage with switch-off,...
  • Page 17 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Environmental conditions Operation ........IEC 60721 Part 3-3 Class 3K22 / 3Z1 / 3B2 / 3C2 / 3S6 / 3M11 Condensation not permitted.
  • Page 18 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Collective fault relay ......Potential-free with safe isolation to the DC output, contact load capacity: max. 250 V AC / 8 A (resistive) max.
  • Page 19: Type Overview: Technical Data

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Type overview: Technical data Type AC2000 N1 AC3000 N1 DC2000 N1 DC3000 N1 E230 G24/65 E230 G24/100 G220 G26/65 G220 G26/100 BWrg-Cü BWrg-Cü...
  • Page 20 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Type AC2000 N1 AC3000 N1 DC2000 N1 DC3000 N1 E230 G24/65 E230 G24/100 G220 G26/65 G220 G26/100 BWrg-Cü BWrg-Cü Wrg-Cü Wrg-Cü DC undervoltage response value ≤...
  • Page 21: Derating

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Derating The derating must be maintained under all circumstances by designing the system accordingly in order to obtain the optimum service life from the appliance.
  • Page 22: Dimension Drawing

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Dimension drawing 80001533 EFE en Page 22 of 41...
  • Page 23 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Illustration 5: Dimensional drawing. 80001533 EFE en Page 23 of 41...
  • Page 24: Preparing The Product For Use

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions PREPARING THE PRODUCT FOR USE Safety measures before use Before connecting to the mains, check that the mains voltage information on the rating plate corresponds to the existing mains voltage.
  • Page 25: Safe Disposal Of The Packaging Material

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Safe disposal of the packaging material The following section provides information on how to dispose of the individual components of the system. Packaging: Dispose of the stretch film and molded polyethylene foam parts with normal industrial waste.
  • Page 26: Preparatory Work Before Installation

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Preparatory work before installation NOTE: The leakage current is greater than 3.5 mA. A protective conductor connection must be established before commissioning; the use of RCDs alone is not permitted.
  • Page 27: Remote Signal Connections X11 And X12

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions The input must be fused outside the appliance (section 4). 5.5.2 DC output X2 (U ) Please observe the torque specification in the technical data (section 4).
  • Page 28 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions A maximum of six devices can be arranged one above the other in a cabinet. A distance of 134 mm (= 3 U) must be maintained between the appliances.
  • Page 29: Operating Instructions

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions OPERATING INSTRUCTIONS Safe operation/safe functioning The appliance is operated exclusively from the front using the controls located on the front panel. These are described in the respective chapters and can be assigned using the labelling on the front panel of the appliance.
  • Page 30 Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions 1% Droop 100% Rated Illustration 7: IU characteristic curve. 80001533 EFE en Page 30 of 41...
  • Page 31: Dynamics Of The Output Voltage

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions 6.2.4 Dynamics of the output voltage With sudden load changes of 10-90 % or 90-10 %, the voltage deviation U is < 5 %. This is regulated within 1 ms.
  • Page 32: Network Monitoring

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions However, the factory setting should only be adjusted in exceptional cases! Procedure: Increase the load until the set current limit responds. Adjust potentiometer I ≤...
  • Page 33: 6.2. 7 Output Monitoring

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions 6.2. 7 Output monitoring The front panel contains the setting potentiometers and LED indicators for the following monitoring functions: Supply status display (LED H1) lights up when the input voltage is within the permissible range.
  • Page 34: External Setpoint Specification

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions 6.3.2 External sensing line output voltage U It is possible to regulate a voltage drop of max. 1 V on both the plus and minus output lines.
  • Page 35: Internal Setpoint Specification

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions 6.3.4 Internal setpoint specification If the internal setpoint is selected (factory setting), it is possible to select one of 4 internal setpoints via terminals X12:1-4. To do this, either X12:1 and X12:2 or X12:3 and X12:4 must be bridged (see table below).
  • Page 36: Special Functions

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Special functions 6.4. 1 Parallel operation Due to the inclination of the voltage level of approx. 1 %, a load distribution of approx. 10 % of the nominal system current is achieved when several switched-mode power supply units are operated in parallel.
  • Page 37: Block Diagram

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Block diagram Power stage Electrical isolation Primary Secondary ‐X1 ‐X2 Mains  PFC booster Full bridge Synchronous  Output  filter (step‐up  rectifier filter converter) L‐ Monitoring & control LED H1 Supply ‐X1 ‐ X11...
  • Page 38: Maintenance And Repair

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions MAINTENANCE AND REPAIR Safety measures DANGER! Risk of electric shock!  The appliance must be disconnected from the power supply before maintenance work. Always observe the...
  • Page 39: Maintenance Schedule

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Maintenance schedule Compliance with the maintenance schedule is necessary to maintain availability. Period Activity Every 12 Visual inspection and cleaning of the appliance if months necessary.
  • Page 40: Troubleshooting, Fault Diagnosis And Repair

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions Troubleshooting, fault diagnosis and repair 7.6.1 No output voltage present  Mains voltage present at X1 and within tolerance? Upstream fuses checked? For devices in the DC series: correct polarity? ...
  • Page 41: Decommissioning And Disposal

    Switch-mode power supply AC2000 N1 / DC2000 N1 / AC3000 N1 / DC3000 N1 - Operating instructions DECOMMISSIONING AND DISPOSAL The device must be disconnected before removal. Then remove the supply lines from the input, output and control circuit. The input and output circuits of the device contain capacitors that may still be live after the mains voltage has been switched off (discharge time longer than 1 minute).

This manual is also suitable for:

Ac3000 n1Dc2000 n1Dc3000 n1