product description Enware water chillers supply chilled water on demand. Suitable for public areas such as gyms, building sites and office buildings. KEY FEATURES • Flow rate of up to 18 litres/hour of chilled water • 4 Litre storage tank •...
technical data Chilled Water Production up to 18 Litres/hour Recommended Water 50-500 kPa Supply Pressure (Use of pressure reduction valve is recommended if inlet pressure may exceed 500 kPa) Power Supply 230-240V / 50 Hz Power Connection 3 pin 10 A plug with 2m lead IP Rating IP23 Water Inlet Connection...
Page 4
WARNING: • Enware water chillers are not suitable for outdoor use. The appliance must not be exposed to rain. • Stainless steel panel (non-powder coated) chillers are not designed or recommended for use in corrosive environments such as enclosed chlorinated pool areas. •...
installation Water chiller is ready for final assembly on site. Remove water chiller from the packaging. Remove the front panel of the chiller unit by unscrewing FRONT PANEL the two fixing screws. Pull panel forward and slide down to FIXING SCREWS remove the front panel.
WATER CHILLER INSTALLATION 1. Place water chiller in desired position and adjust levelling feet so that the water chiller is stable and sitting level. CONNECT TO 40MM WASTE Note: This appliance must be placed in a horizontal position. Ensure there is at least 50mm of gap between the back of BOTTLE the unit and any wall for fan ventilation.
Page 7
CARAFE FILLER ASSEMBLY INSTRUCTIONS 1. Align the brass adjusting nut so that it sits ADJUSTMENT NUT SLIDE HANDLE ON crosswise. SEE IMAGE 6 POSITIONED FROM THIS SIDE CROSS-WISE 2. From the tapered end of the handle, start to slide the handle on to the nut, making sure the adjusting nut stays in the crosswise direction.
operation CARAFE FILLER BUBBLER To turn on water flow, push handle down. To turn on water flow, push button down. To turn off water flow, let go of handle. To turn off water flow, let go of button. Water flow stops automatically. Water flow stops automatically.
service & maintenance Every 6 months or periodically as required, the appliance and its surrounding area should be inspected for water leaks, the carafe filler and bubbler should be tested for correct operation and external panels should be given a light wipedown. Filters if used should be replaced, depending on usage.
troubleshooting WATER CHILLER PROBLEM CAUSE RECTIFICATION No water at outlets Water not connected or turned Connect and turn on water supply Water frozen Adjust water temperature control on thermostat to higher setting. Do not operate the appliance, until ambient temperature is again above 0°C and frozen unit has completely thawed.
Page 12
product warranty for Australia Effective May 2023 exceptions Enware Pty Ltd (“we” or “us”) warrants that this product (also referred to as “our goods”) will be free from all defects in materials and workmanship for 12 This warranty does not apply in respect of any months from the date of purchase.
Need help?
Do you have a question about the ENWARE DFSA120 and is the answer not in the manual?
Questions and answers