USER AND MAINTENANCE MANUAL
Ø 35 mm tubular motors with mechanical limit switch
Dear Customer, thank you for purchasing a STAFER product. This manual describes the operations necessary for the correct installation of the V6 / VM6 / V7 / VM7 products. These
tubular motors with mechanical limit switches are suitable for handling the most popular types of rolling shutters. The motor's technical specifications are shown on the label affixed to
the motor tube. These devices have not been designed for round-the-clock use. Any use of the product other than what is provided herein is improper and prohibited, and involves
warranty voidance and liability disclaimer by the Manufacturer. The product must be assembled and installed only by a qualified technician. At the end of installation, all the manuals
accompanying the product must be delivered to the end customer, who must keep them for future reference. Visit the site www.stafer.com to view updated documents, if any.
Index
01. Technical specifications
02. Warnings
03. Rating tables and motor components
04. Adapter assembly
05. Electrical connection
06. Limit switch adjustment
www.stafer.com
01. TECHNICAL SPECIFICATIONS
The motor's technical features are shown on the label affixed to the motor tube. Before installing the motor, we recommend that you copy the technical data (including the full product
name) and store them in a safe place. These data could be useful at the time of maintenance or technical assistance. Additional features common to the V6 / VM6 / V7 motor family.
Power supply
Idle consumption
Minimum V4 roller diameter
02. WARNINGS
02.1 Safety warnings
Incorrect installation can cause serious injuries.
and maintenance operations must be carried out only by a qualified and skilled technician, who must comply with laws, provisions and local regulations, and the instructions provided
●
herein
Wiring must comply with current CEI standards. In compliance with the provisions of Italian Ministerial Decree 37/2008, the final electrical system must be installed only by an
●
electrician.
To prevent potentially dangerous situations, regularly check the operating condition of the rolling shutter/awning.
02.2 Installation warnings
Check that the package is intact and has not been damaged during transport.
●
the motor.
Do not pierce or tamper with the motor in any way. Do not modify or replace parts without the Manufacturer's permission.
the power cable is damaged, the product cannot be used. Do not attempt to replace the power cable.
●
contact with the motor.
The motor must be of power adequate to the charge (check the rating plate data on the motor).
mm clearance on right/left on the coiler.
and supports must be selected exclusively from the STAFER catalogue.
necessary to protect the moving parts with a cover, in order to prevent accidental access. In any case, guarantee access for maintenance operations.
positioned in such a way as to avoid contact with moving parts.
●
If there are several radio appliances in the same system, make sure they are at least 1.5m apart.
rolling shutter, but away from its moving parts. Place the buttons at a height greater than 1.5 m from the floor.
continuous maximum work time of 4 minutes.
safety device, which stops the motor in the event of overheating. The motor returns to normal operation when its temperature drops below the safety limit (normally from 10 to 15
●
minutes).
The motor must be installed in such a way that it does not come into contact with liquids and, in any case, in a location protected from the elements.
subjected to mains voltage. It is forbidden and dangerous to tamper with the antenna cable. Replace the product if the antenna cable is damaged.
the coiler while the motor is powered.
02.3 Use warnings
The product is not intended to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are
supervised or given instructions about the product way of use by a person responsible for their safety.
the area affected by the movement of the rolling shutter. Check the automation during operation and keep people at a safe distance until the end of operation.
play with the appliance or with control devices.
is automatic, disconnect the motor from the power line.
03. CAPACITY TABLES AND MOTOR COMPONENTS
Model Torque Nm
V4-7/24
7 Nm
V4-9/17
9 Nm
A=limit switch adjustment screws / B=base crown / C=insertion key / D=adapter crown / E=output pinion /
F=drive pulley / G=coupling tooth / H=coupling clips (to remove the pulley, widen the clips and pull lightly) /
I=gearmotor body / J=nameplate data / K=power cable
recycled paper
VIDEO TUTORIAL
: 230 Vac 50 Hz
Protection grade
: < 0,5W
Insulation class V6/VM6
: 40 x 1.5
Maximum limit
●
Keep these instructions for future maintenance operations and the disposal of the product.
●
Check that the drive pulley and the adapter crown are of shape and dimensions appropriate for the coiler used. Motor accessories, adapters
●
The product power cable is suitable for indoor installation only. If installing outdoors, lay the cable in a protective tube.
●
During operation, the motor body reaches high temperatures: use caution.
Do not operate the rolling shutter when maintenance operations are being carried out (e.g. window cleaning, etc.). If the control device
●
rpm
Power W
24
125
17
125
V4
Let's protect the environment
Protecting the environment is everyone's duty! STAFER uses recyclable packaging
materials. Dispose of materials in proper containers, in compliance with laws in force in
your location. If you are an installer and use a large number of motors, ask your dealer or
the Company about receiving motors in "honeycomb pads", an environmentally friendly
choice that limits clutter and waste by significantly reducing the amount of packaging
materials. This product may contain substances that are polluting for the environment
and dangerous to health. At the end of the product life cycle, carefully comply with the
appropriate waste disposal rules. It is hazardous, and thus strictly forbidden to dispose
of the product in the domestic waste.
: Ip44
: H
RX.3
: 28
●
A heavy shock and the use of unsuitable tools can cause the damage of the external or internal parts of
●
Make sure that screws required to complete the installation do not come into
●
If the product is installed at a height of less than 2.5 m from the floor or other supporting surface, it is
●
Do not install the product near metal surfaces.
●
Before operating the rolling shutter, make sure that people or things are not in
●
01
Revolving operating time
●
All the product installation, connection,
●
Do not handle the motor by the power cable. If
●
Use coilers with a minimum thickness of 10/10.
●
Position the buttons in view of the
The motors are designed for residential use; they are designed for a
●
The motor is internally fitted with a self-restoring thermal
●
For your safety, do not work near
INSTRUCTIONS
TRANSLATED
FROM THE ORIGINAL
: 4 minutes
●
Leave 1-2
●
The power cable must be
●
The antenna cable is
Do not allow children to
●
versione 1.0
Need help?
Do you have a question about the V4 and is the answer not in the manual?
Questions and answers