Do you have a question about the X1 and is the answer not in the manual?
Questions and answers
Summary of Contents for CINGOL X1
Page 1
X1 Series Dental Unit -Operating Manual Add: Building 6-1,Nansha Industrial Village Jiangli North Rd,Danzao Town, Nanhai District,Foshan ,Guangdong,China www.cingol.com...
X1 Series Dental Unit -Operating Manual Contents 1 General information............................3 1.1 Dear Customer,...........................3 1.2 Contact information..........................3 1.3 Notes on Operating Manual......................3 1.3.1 General information on Operating Manual................ 3 1.3.2 Scope of these Operating Manual..................3 1.4 Other valid documents........................4 1.5 Warranty and liability..........................
Page 3
X1 Series Dental Unit -Operating Manual 4.3.2 Armrest........................... 18 4.3.3 Adjusting the headrest......................19 4.3.4 Moving the patient chair.......................19 4.3.5 Moving the patient chair to the entry/exit position............20 4.3.6 Moving the patient chair to the emergency position............21 4.3.7 Moving the patient chair to the clean-up position............21 4.3.8 Music panel..........................
X1 Series Dental Unit -Operating Manual 1 General information Dear Customer, We are pleased of your purchase on the X1 dental unit. X1 that chosen as your dental unit stands for the features of easy operation, innovative comfort and high quality design.
X1 Series Dental Unit -Operating Manual 1.4 Other valid documents You dental unit can be equipped with additional components that are described in separate sets of Operating Manual. The Manual as well as any warning and safety information contained therein also must be observed.
X1 Series Dental Unit -Operating Manual 2 Safety information 2.1 Identification of danger levels To prevent personal injury and material damage, please observe the warning and safety information provided in this document. Such information is highlighted as follows: WARNING !...
X1 Series Dental Unit -Operating Manual 2.5 Maintenance and repair Authorized technical As manufacturers of dental units and in the interest of the operational personnel and spare safety of your unit, we stress the importance of having maintenance parts and repair of this unit performed only by ourselves or by agencies expressly authorized by us.
2.10 Care and cleaning agents Unsuitable may corrode the surface of the unit. Therefore, use only care and cleaning agents which have been approved by CINGOL. For more information. 2.11 Modifications and extensions of the unit Modifications to this unit which might affect the safety to the unit owner, patients or other persons are prohibited by law.
X1 Series Dental Unit -Operating Manual 3 Unit description 3.1 Standards/approvals The X1 dental unit complies with the following standards, among others: IEC 60364-7-710 IEC 60601-1:2005+A1:2012 IEC 60601-1:2006+A1:2013 IEC80601-2-60 ISO 7494-1:2018 ISO 7494-2:2003 ISO 9680:2007 ...
X1 Series Dental Unit -Operating Manual 3.3 Dental unit overview The dental unit comprises the following main components: X1 Dental Unit (Top-Mounted ) (push button) I Lamp arm Chair Base Air Lock Q Balance Arm E Headrest F Assistant Instrument...
Page 12
X1 Series Dental Unit -Operating Manual X1 Dental Unit (Hanging Type) (push button) Lamp arm Chair Base Air Lock E Headrest F Assistant X-Ray Film Balance arm Cushion controller Viewer Doctor Tray K Air pressure G Spittoon Backrest meter Instrument tray...
Page 13
X1 Series Dental Unit -Operating Manual X1 Dental Unit (Cart Type) (push button) Touch panel Headrest Sidebox Lamp Arm Armrest Xray Film viewer Seat cushion Assistant tray K Instrument Tray Cover Backrest Cuspidor Foot Pedal Led lamp Music player panel Add: Building 6-1,Nansha Industrial Village Jiangli North Rd,Danzao Town, Nanhai District,Foshan ,Guangdong,China www.cingol.com...
X1 Series Dental Unit -Operating Manual 3.4.Installation and setting 3.4.1 Installation conditions To make sure dental unit work well the conditions of air, water, electricity for the device should be: Air supply&air pressure: 0.5 MPa--0.8MPa Water supply&Water pressure: 0.2MPa--0.4MPa Power supply: AC 230±10% /AC 110±10% 50Hz/60Hz ( the rated voltage according to different country refers to the order) 3.4.2 Preparation for installation...
X1 Series Dental Unit -Operating Manual the balance arm,and fix with screw. F)Connect power supply Put the plug into the power socket,which must have the wire connected to ground.the wire should have the copper wire inside less than 1mm make sure this wire connected well with ground.
X1 Series Dental Unit -Operating Manual 4 Operation 4.1 Starting up the dental unit 4.1.1 Initial start-up Sanitation must be performed prior to initial start-up of your dental unit. Sanitation takes approx. 24 hours. 4.1.2 Switching the dental unit on/off The dental unit thus features a main switch at the patient chair and an emergency switch at back of the patient chair.
Page 17
X1 Series Dental Unit -Operating Manual Operating foot switch The foot switch use to control movement of the patient chair. Uplifted or descending the chair couch movement can be controlled by sliding the foot switch to the up or down. Similarly, backward or forward backrest movement can be controlled by sliding the foot switch to the left or right.
X1 Series Dental Unit -Operating Manual 4.3 Patient chair The patient chair comprises the following main components: Chair base and cover Seat Backrest Headrest Left armrest 4.3.1 Safety instructions ! WARNING The free space under the patient couch and up to the water unit can be decreased due to chair movements.
X1 Series Dental Unit -Operating Manual WARNING Objects protrude into the movement range of the chair. There is a risk of crushing the patient and damaging the objects. Make sure that no objects such as e.g. windows, drawers or other ...
X1 Series Dental Unit -Operating Manual 4.3.4 Moving the patient chair The chair movement can be controlled via the fixed keys on the dentist element and the assistant element, or via the foot switch. Via the dentist element Picture of the control panel on the dentist element, see “The control panel on the dentist element”.
X1 Series Dental Unit -Operating Manual 4.3.6 Moving the patient chair to the emergency position When the emergency position key is pressed, the patient chair immediately moves to a position suitable for emergency position of the patient. The patient chair moves up to highest position.
Bluetooth connection: Press the Pause button few seconds,It will enter blue-tooth mode when power-on with the “ hello CINGOL ” voice. Or when play the music list from flash drive, long press MODE changing button to switch to blue-tooth mode, a “ding” sound will be heard at the same time.
X1 Series Dental Unit -Operating Manual 4.4.1 Maximum load capacity The maximum load of the dentist element is 1.5 kg(same for hanging type and top-mounted ). 4.4.2 Height adjustment (Apply to X1) 1. Hold the handle and press the locking button by the thumb.
Page 24
X1 Series Dental Unit -Operating Manual 4.4.3.3 Flushing of the cuspidor bowl Press the key (Flushing). The flushing function is activated for the Flushing preset flushing time. Pressing the key (Flushing) again stops the flushing function immediately. Setting the flushing time Setting 1.
X1 Series Dental Unit -Operating Manual 4.4.4 Placing the instruments in their holders Every handpiece has a corresponding switch on the holder. When the handpiece is removing to their holder, the switch will open the pile-up valve and the removed handpiece is unlocked.
X1 Series Dental Unit -Operating Manual Water regulating valve for the syringe in the first holder Water regulating valve for the handpiece in the second holder Water regulating valve for the handpiece in the third holder Water regulating valve for the handpiece in the forth holder...
X1 Series Dental Unit -Operating Manual Assistant element The dentist element comprises the following main components: Control panel Instruction holder Spray aspirator Saliva ejector 3-way syringe 4.5.1 Moving the assistant element The assistant element can be moved in the dental assistant’s field of activity, but can’t be adjusted in height.
X1 Series Dental Unit -Operating Manual 4.5.3 3-way syringe See “4.4.8 3-way syringe”. 4.5.4 Saliva ejector A curved cannula that can be lodged in the corners of the mouth is provided for saliva ejection. Saliva ejection can be used when it is removed from the holder.
X1 Series Dental Unit -Operating Manual 4.6.1 Tumbler filler Tumbler Filling Tumbler filling can be achieved via the key (Tumbler Filling) on the dentist element or on the assistant element. See “4.4.3.2 Water unit area / Tumbler filler”. 4.6.2 Flushing the swiveling cuspidor bowl...
X1 Series Dental Unit -Operating Manual 4.6.4 Air switch The air switch is pulled to the ON position. Air is filled in the pure water bottle to supply the preset pressure for the pure water flowing to the dentist element.
X1 Series Dental Unit -Operating Manual 5 Cleaning and maintenance by the practice team To maintain the value and safe functioning of your dental unit, it is necessary to have it cared for, cleaned and disinfected by the practice team regularly. This will minimize the risk of contamination for patients and users and ensure proper functioning.
Page 32
X1 Series Dental Unit -Operating Manual Add: Building 6-1,Nansha Industrial Village Jiangli North Rd,Danzao Town, Nanhai District,Foshan ,Guangdong,China www.cingol.com...
Page 33
X1 Series Dental Unit -Operating Manual Add: Building 6-1,Nansha Industrial Village Jiangli North Rd,Danzao Town, Nanhai District,Foshan ,Guangdong,China www.cingol.com...
X1 Series Dental Unit -Operating Manual 6 Maintenance by the service engineer Inspection and maintenance In order to ensure the operational safety and reliability of your dental unit and to avoid damage due to nature wear, annual inspection and maintenance must be performed on your dental unit. This is done by an authorized service engineer.
X1 Series Dental Unit -Operating Manual 7 Malfunctions Some common fault is following table: Fault Reason Analysis action Dripping The mebrane of the pile-up valve has been Change a new mebrane handpiece damaged The water valve switching on by air has...
X1 Series Dental Unit -Operating Manual 8 Disposal The dental unit not only belongs to medical equipment, it also belongs to electronic equipment. The product must not be disposed of as domestic refuse! Please observe the disposal regulations applicable in your country.
X1 Series Dental Unit -Operating Manual 9 Overview of graphic symbols used symbols Definition symbols Definition Chair Memory Position Clockwise to increase Clockwise to reduce Choose doctor Chair up Caution electric shock Chair down Protective grounding Caution, consult Backrest up...
X1 Series Dental Unit -Operating Manual 10 Electrical schematic diagram Add: Building 6-1,Nansha Industrial Village Jiangli North Rd,Danzao Town, Nanhai District,Foshan ,Guangdong,China www.cingol.com...
X1 Series Dental Unit -Operating Manual 11 Water-air layout diagram Add: Building 6-1,Nansha Industrial Village Jiangli North Rd,Danzao Town, Nanhai District,Foshan ,Guangdong,China www.cingol.com...
Page 40
X1 Series Dental Unit -Operating Manual Add: Building 6-1,Nansha Industrial Village Jiangli North Rd,Danzao Town, Nanhai District,Foshan ,Guangdong,China www.cingol.com...
Need help?
Do you have a question about the X1 and is the answer not in the manual?
Questions and answers