2 INTRODUCTION Thank you for choosing the SGA 400 Gas analyzer. We hope this product will be of good use to you for many years to come. The SGA 400 Gas analyzer has been developed to meet the high demands of a modern gas analyzer.
If the Company incurs liability towards any third party for such damage to property as described in the preceding paragraph, the Purchaser shall indemnify, defend and hold the Company harmless. If a claim for damage as described in this clause is lodged by a third party against one of the parties, the latter party shall forthwith inform the other party thereof in writing.
7 SGA 400 DESCRIPTION 7.1 FRONT PANEL 1. Display for CO 10. Indicator for multiplication of displayed value. 2. Display for CO (If indicator is lit, reading should be multiplied 3. Display for Oil temperature by 10) 4. Display for HC 11.
REAR PANEL 20. Oxygen sensor 25. Gas & Water outlet 21. NO sensor 26. Calibration gas inlet 22. Fine filter 27. Connection to smoke meter (opacimeter, 23. Water separator filter SST 100) 24. Sample gas inlet 28. Power supply connector 7.2 RIGHT SIDE PANEL 30.
8 INSTALLATION 8.1 POWER CONNECTION Connect the supplied main cable to the net adaptor. Connect the short DC cable to the net adaptor and to the machines DC connector (28) on its rear panel. Connect the main cable to a wall outlet 100-240 VAC (50/60 Hz). Now the machine can be switched on and off with the "Power"...
9 OPERATION SEMS Starting screen of the SEMS software. You can use the following buttons to navigate: Arrows up and down in menus Enter to go forward in the sequence ESC to cancel or go back You can also use the mouse. “MOT procedure”...
Every 12 months: Gas calibration (chapter 8.6.2), (local regulations can stipulate shorter interval than 12 months) At ”E 03” indication (and ”E 24” or Replace the O transducer (see below) ”E 64) At ”E 27” indication: Replace the NO transducer (see below) 10.1 CLEANING Keep cover, display, and keys clean using a dust-free cloth with a little washing-up liquid.
Page 10
NOTE: The O transducer contains hazardous chemicals, do not try to disassemble it, leave used O sensors to an environmental recycling station. transducer is replaced as follows: 1. SGA 400 may be in pause mode or turned off. 2. Unfasten the connection in the middle of the O2 transducer by gripping its short sides with a small pair of pliers and pull it straight backwards.
11 TROUBLE SHOOTING 11.1 ERROR AT LEAK TEST If the leak test result failed, a leakage may exist in the hose system leading to the pump. Disconnect the sampling hose from the analyzer cap the sample gas inlet (26) on the rear panel of the analyzer and do a new leak test.
13 DIESEL SMOKE MEASUREMENT (OPTION) The smoke diesel kit SST 100 can be connected to SGA 400 and enables user to sample sot from diesel vehicles. The smoke diesel kit includes the following: SST 100 smoke analyzer 1,4 meter smoke gas hose and probe for diesel cars ...
Page 14
The smoke unit is used when sampling on diesel vehicles. Sampling probe for diesel vehicles (Smoke gas probe) Smoke unit SST 100 Power Power DC supply cable 230 VAC – Communicati on cable Power Power DC supply cable 230 VAC – Wall socket Remote...
This is how you connect the smoke tester to the gas analyzer: 1. Shut down the whole equipment from power. 2. Fit the smoke probe with its hose to the smoke unit by pressing the hose to the connector on the front side. 3.
15 MAINTENANCE 15.1 CLEANING THE SAMPLE UNIT 1. Unscrew the two screws that hold the outlet pipes on their place and remove the pipes. 2. Please never insert the cleaning brush straight in to the channel of the smoke outlet flow. The blades of the fan just a few inches inside the opacimeter will break if the brush gets to them while the fans are rotating.
Page 17
5. Use a dry or slightly moistened cloth to clean the optics, both sides. 6. Reassemble the outlet pipes on the opacimeter. 8/6/2018...
16 LINEARITY TEST This test is performed automatically using electronic calibration. The electronic opacity test is pre a preset and documented k-value applied to sampling optics (this procedure is normally called Weekly Linearity Test). The generated electronic K value is compared to a preset k-value of 1.80m-1 The difference may be no greater than ±0.1m-1.
18 CONSUMABLES AND SPARES Item name Item no O2- cell 525011 Pre filter 525015 Fine filter SGA 400 (2 x 5 pack) 528422 Double Hose, Twin Probe and pre filter complete - gas analyzer 525025 Cleaning brush 85000 For other spare parts or accessories please contact your dealer. ITEMS RELATED TO CONSUMPTION AND ACCESSORIES FOR SGA 400 AND SST 100 Item no: 525011...
Page 21
Item no: 525025 Item name: Double Hose, Twin Probe and pre filter complete - gas analyzer Fits for: SGA 400 Item no: 85000 Item name: Cleaning brush for SGA 500 smoke units Fits for: SST 100 8/6/2018...