Page 1
Instruments and System for Geotechnical and Structural Monitoring Datalogger CUM3000 Instruction Manual Pizzi Instruments S.r.l. Via del Fornaccio, 46 – 50012 Bagno a Ripoli (FI) Italy Tel. 0039 (0)55 6810722 – Fax 0039 (0)55 6584923 – email: info@pizzi-instruments.it - web: www.pizzi-instruments.it...
Page 2
Pizzi Instruments S.r.l. is not liable for any damage or loss caused to other equipment or person, whether direct, indirect, incidental, special or consequential which the buyer may experience as a result of the installation or use of the product.
Before any installation, maintenance or intervention on the instrument make sure that the switch is off. Some components may be energized and an inadvertent contact with them could damage the equipment in addition to causing serious damage to the person. Do not remove the Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 4/26...
Read the operating manual and instructions, see the symbols relating to security The symbol ATTENTION highlights the presence of a potential danger . ATTENTION: personal injuries. All the indication contained in this manual must be fully acquired and understood before proceeding Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 5/26...
These procedures present a real simplicity of use that allows the execution even without specific personnel training . The new unit is available in aluminum container with an appropriate and intuitive connection on the bottom for the mounting on DIN bar. Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 6/26...
Insurance claims may be void if the above procedure is not followed With regards to any faults or defects that can be recognized during proper inspection upon receipt, a complaint shall be filled and send to Pizzi Instruments within seven days of receipt of goods. 3. Storage on site ...
The installation of this instruments requires the following equipment: Different equipment to install the protection box Different equipment for the cables preparation and attachment of the wires to the connectors or terminal blocks. Multimeter Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 8/26...
There is also an alphanumeric display on which messages of program and other information will be visualized as well other indication of service and work (required for programming and accessing data on site). Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 9/26...
WAIT will appear for a time of max. 20 sec. This interval is necessary to give the Unit the time to configure all the setting in memory; later on the display the following window of “Attesa/acquisizione” will appear : aa/bb/cc hh:mm xxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxx AA/BB/CC HH:MM Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 10/26...
Page 11
Whenever you enter the menu or you want to return to it, after having set the various items of interest, the cursor is always placed in correspondence of the function "ACQUISITION". Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 11/26...
(groups of instruments and their timing). 6.4 Acquisition From the main menu, positionning the “indicator arrow” on ACQUISITION and pressing the button “E” on the display the following window will appear: aa/bb/cc hh:mm Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 12/26...
Page 13
: XXX = number of interested channel = first alarm code = second alarm code In case of single alarm one of the two numbers will be the "zero". Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 13/26...
Instruments and System for Geotechnical and Structural Monitoring 6.5 Manual measure From the main menu, moving the “arrow indicator” on ↓ and on the command MISURA MANUALE and pressing the button “E” the following window appears : Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 14/26...
Page 15
MANUAL MEASURE, hence, by pressing the confirmation button on the PREVIOUS MENU you get to the main menu from where you can start the item ACQUISITION the acquisition cycle timed according to the parameters that you have set. Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 15/26...
Page 16
Instruments and System for Geotechnical and Structural Monitoring Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 16/26...
Page 17
Instruments and System for Geotechnical and Structural Monitoring Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 17/26...
Page 18
OK for regular operation, b) indication of alarm (xx) in case of malfunction. Where: xx= alarm code generated from the test execution of the related test respectively to the functions indicated in the second column, that is : Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 18/26...
Where X X X X X : address memory in the first memorized measure (being the memoryy at loop and indicates which is the address of the first measure in memory) Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 19/26...
To go to one field to another, you use the →, to go to the subsequent data field and to the previos data field you use ←. The different available timing are set as follows : Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 20/26...
0 0 : 0 0 To move from an item to another we will use the keys ←and → ;to change the parameters we will use the keys ↑ and ↓. Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 21/26...
T E L . :X X X X X X X X X X X X X X X X Where: M O D E : Type of used connection ; using the keys ↑↓ you can select the following possibilities: -RS232 : direct connection RS232 Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 22/26...
Page 23
± X X X X • X X X X X ± X X X X • X X X X X X X T W U X X X < M > < D W > Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 23/26...
Page 24
Move on the number with the cursor (key ___) and insert first the sign with the key “__“ and then the value of “K” with the numeric keyboard; the comma is inserted with the proper key. • OF = value of a possible OFFSET. Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 24/26...
Page 25
- MT/SEC meters/seconds - MT3/SEC cubic meters /seconds - LT/SEC liter / second percentage value - W/MT Solar radiation - Khz frequency squared - mA milliampere - ---- no measuring unit Instruction Manual – Datalogger CUM3000 Rev.003 – 03/09/2020 25/26...
For the insertion proceeds as described for SS. 7. Instruments Services and Support Pizzi Instruments offers a variety of services including telephone support, installation, training, calibration, repair and maintenance For further information please contact directly our office at the follow address or visit our web site: www.pizzi-instruments.it...
Need help?
Do you have a question about the CUM3000 and is the answer not in the manual?
Questions and answers