CommLink 6
Technical Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CommLink 6 and is the answer not in the manual?

Questions and answers

Summary of Contents for AAON CommLink 6

  • Page 1 CommLink 6 Technical Guide...
  • Page 2 This manual is available for download from www.aaon.com AAON, Inc. It is the intent of AAON to provide accurate and current product 2425 South Yukon Ave. information. However, in the interest of product improvement, AAON Tulsa, OK 74107-2728 reserves the right to change pricing, specifications, and/or design of its Factory Technical Support Phone: 918-382-6450 product without notice, obligation, or liability.
  • Page 3: Table Of Contents

    Quick Start Guide ..............................6 CONNECTIONS AND WIRING ......................... 7 Connections and Wiring ............................7 SETUP ................................. 8 COM Port ................................8 Prism 2 ..................................9 TROUBLESHOOTING ............................. 11 CommLink 6 LEDs ..............................11 Connection ................................12 CommLink 6 Technical Guide...
  • Page 4 TABLE OF FIGURES FIGURES Figure 1: CommLink 6 Wiring ............................7 Figure 2: CommLink 6 LEDs ...........................11 CommLink 6 Technical Guide...
  • Page 5: General Information

    CommLink power terminal block or serious damage to the product will result. System Requirements To program the CommLink 6 to work with Prism 2, you will need: Standard Items (Required) • CommLink 6 with USB cable and power adapter (supplied) •...
  • Page 6: Installation

    Incorrect wiring could lead to damage of the equipment. • Multiple when there is a single CommLink 6 with at least one MiniLink PD 5 installed in the system. • Single when there is a single CommLink 6 with...
  • Page 7: Connections And Wiring

    CONNECTIONS AND WIRING Connections and Wiring All MiniLink and CommLink 6 baud NOTE: rates must match. If in single loop When using where you do not have MiniLinks, the a MiniLink, CommLink baud must match all switch should connected baud rates.
  • Page 8: Setup

    Changing the USB COM Port Number When the CommLink 6 is first plugged in, it will be assigned a COM port number to be used for communicating with the Prism 2 software. If the port number is 10 or greater, it needs to be changed...
  • Page 9: Prism 2

    Location box and press <Enter> In the Serial Port field, click on the pull down box and Step 6: select the COM Port number that the CommLink 6 is using. The Search for Installed Units Window will pop up. Click Step 12: located in the upper left-hand corner <Start Search>...
  • Page 10 If Units Found on this Loop stays at zero, check the Step 14: wiring to the CommLink 6 and the AHU/RTU Controllers and/or read through these directions again to make sure all steps were followed.
  • Page 11: Troubleshooting

    This LED flickers when data is exchanged turn on solid once you plug the ethernet cable into the with the controller network. CommLink 6 and remain lit as long as the connection is not lost. Indicates transmitted data status of USB connection.
  • Page 12: Connection

    IP Address of the CommLink 6. problems. Only with proper configuration of the Firewall/Proxy are connections to the CommLink 6 from outside of the local area network going to be possible. Check that the Firewall/Proxy TCP port 39288 is not AAON Controls Support cannot troubleshoot NOTE: firewalls, routers, and/or problems on a customer’s...
  • Page 13 PARTS: For replacement parts, please contact your local AAON Representative. 2425 So. Yukon Ave • Tulsa, OK • 74107-2728 Ph: (918) 583-2266 • Fax: (918) 583-6094 Rev. A Created in the USA • © AUGUST 2024 AAON All Rights Reserved...