Austin Hughes InfraPower PPS-04-S User Manual

Gui & snmp for z ip pdu webui

Advertisement

Quick Links

Inspired by Your Data Center
User Manual -
PPS-04-S
GUI & SNMP for Z series IP PDU
Z meter
M meter
Designed and manufactured by Austin Hughes
UM-PPS-04-S-Q224V1
www.austin-hughes.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InfraPower PPS-04-S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Austin Hughes InfraPower PPS-04-S

  • Page 1 Inspired by Your Data Center User Manual - PPS-04-S GUI & SNMP for Z series IP PDU Z meter M meter Designed and manufactured by Austin Hughes UM-PPS-04-S-Q224V1 www.austin-hughes.com...
  • Page 2 Legal Information First English printing, April 2024 Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. The information in this document is subject to change without notice. We are not liable for any injury or loss that results from the use of this equipment.
  • Page 3: Table Of Contents

    Contents < Section 1 > General < 1.1 > Key Features of PPS-04-S WEBUI < 1.2 > Z series IP PDU Meter Specifi cation < 1.3 > M series serial PDU Meter Specifi cation < 1.4 > Initial network confi guration of Z series IP PDU <...
  • Page 4: Key Features Of Pps-04-S Webui

    < Section 1 > General < 1.1 > Key Features of PPS-04-S WEBUI InfraPower PPS-04-S Features Capacity Max PDU number per Z series IP PDU Concurrent Users Enhanced Power-on Sequencing with Customized Delays Features Customized Outlet Power-on Sequencing ** Outlet Grouping Across Linked PDUs ** Outlet ON / OFF / Power Cycle in Group ** Outlet Level kWh &...
  • Page 5: Z Series Ip Pdu Meter Specifi Cation

    < 1.2 > Z series IP PDU Meter Specifi cation UM-PPS-04-S-Q224V1 www.austin-hughes.com...
  • Page 6: M Series Serial Pdu Meter Specifi Cation

    < 1.3 > M series serial PDU Meter Specifi cation UM-PPS-04-S-Q224V1 www.austin-hughes.com...
  • Page 7: Initial Network Confi Guration Of Z Series Ip Pdu

    < 1.4 > Initial Network Confi guration of Z series IP PDU The Z series IP PDU supports Automatic Private Internet Protocol Addressing ( APIPA ). You can confi gure the Z series IP PDU by connecting it to a computer or to a TCP/IP network that supports DHCP. If the computer or the TCP/IP network does not support DHCP, the Z series IP PDU will confi...
  • Page 8: Pdu Cascade

    < 1.5 > PDU Cascade • One Z series IP PDU can connect max. 31 x PDUs ( M / Z series, One / Three Phase PDU ) • Daisy chain by Cat 5e / 6 cable • Max. cable length 300M. (984 ft) 32 x PDU for 16 Racks Wireless Wired Dual Lan...
  • Page 9: Pdu Level Setting

    < 1.6 > PDU Level Setting 1. PDU Level Setting on local meter display Setup Level Level PDU Level Level Group : Buzzer Level : Screen Sensor Outlet ON Cancel Enter Cancel Enter 2. PDU Level Setting by Remote ( see < 1.8 > Remote PDU Level Setting ) <...
  • Page 10: Remote Pdu Level Setting

    < 1.8 > Remote PDU Level Setting Remote level setting facilitates you to set the PDU level connected to the Z series IP PDU in the same cascade chain remotely. Please follow the steps below to complete the remote level setting. To ensure the correct PDU level setting, please have the serial number of the PDUs and order of the PDUs in the daisy chain.
  • Page 11: Pps-04-S ( Webui For Z Series Ip Pdu )

    < Section 2 > General < 2.1 > PPS-04-S ( WEBUI for Z series IP PDU ) PPS-04-S allows you to monitor and control up to 32 levels of Z / M series PDU in a single cascade chain remotely over a TCP/IP network. In <...
  • Page 12 < 2.1 > PPS-04-S ( WEBUI for Z series IP PDU ) In < Outlet setting >, - Change PDU’s outlet name - Change “ Power up sequence delay ” of PDU’s outlet ( Switched PDU only ) Default : 1 second. Min. 1 seconds, max. 3600 seconds - Change “...
  • Page 13 < 2.1 > PPS-04-S ( WEBUI for Z series IP PDU ) In < Sensor Setting >, - Default Sensor setting : Deactivate - “ Activate ” sensors ONLY when they are connected - Change “ Location ” , “ Rising alert Setting “ &...
  • Page 14: Outlet Grouping

    < 2.2 > Outlet Grouping Outlet Grouping allows you to group multiple outlets from same PDU or across PDUs in the same cascade chain. You can ON / OFF / Power Cycle all the outlets in the Group. Please follow the steps below to complete the Outlet Grouping. 1.
  • Page 15: Outlet Sequencing

    < 2.3 > Outlet Sequencing By default, outlets are powered on ONE by ONE in the ascending order when power ON or power cycle all the outlets on Z / M series PDU. You can change the power ON sequence of the outlets. It is useful for you to set the outlet power ON sequence where some IT equipment should be powered up fi...
  • Page 16 < 2.3 > Outlet Sequencing 2. Select the outlet by clicking on the number next to the outlet icon you want to change the power ON se- quence. Move outlet 4 up in this illustration. 3. Click “ “ button once and outlet 4 moved prior to outlet 3. Click “ Apply ” to complete the settings. The new outlet sequence will apply when power cycle the Z / M series PDU or perform the power on or power cycle operation on partial outlets.
  • Page 17: System

    < 2.4 > System In < System >, - Change Z IP PDU name & location - Change temperature unit displayed in WEBUI - Set the “ Date & Time “ of the IP dongle ( by “ Manually “ or “ NTP server “ ). Default is “ Manually “ - Select “...
  • Page 18: Network

    < 2.5 > Network In < Network >, Z series IP PDU can be confi gured to operate as Dual Lan or failover mode. Default is “ Dual Lan mode ” Dual Lan mode : - Enter LAN 1 “ IPv4 address ”, “ IPv6 address ”, “ Subnet mask ”, “ Gateway ”. ( For static IP setting only) - Enter LAN 2 “...
  • Page 19: Wifi Network Confi Guration

    < 2.6 > Wifi Network Confi guration < Preparation > • Make sure the network meets the security WPA2 - Personal or WPA2 - Enterprise. • Z series IP PDU is powered ON. • Login PPS-04-S WEBUI via L1 / L2 of Z series IP PDU to confi gure the Wifi network. 3rd party WIFI kit is not compatible to InfraPower.
  • Page 20 < 2.6 > Wifi Network Confi guration Step 4. Click “ Scan Wifi ” to search the available Wifi network. Step 5. Select the appropriate network from the pull down menu of “ ESSID ”. UM-PPS-04-S-Q224V1 www.austin-hughes.com P.17...
  • Page 21 < 2.6 > Wifi Network Confi guration Step 6. Select “ PSK “ from Authentication. For PEAP or TLS , please refer to < 2.13 > 802.1X authentication. Step 7. Input “ Password ” for authentication. UM-PPS-04-S-Q224V1 www.austin-hughes.com P.18...
  • Page 22 < 2.6 > Wifi Network Confi guration Step 8. Select “ DHCP ” to “ OFF ”. Default is “ ON ” Step 9. Enter “ IPv4 address ” , “ IPv6 address ” , “ Subnet Mask ” , “ Gateway ” & Click “ Apply ” to fi nish the above settings.
  • Page 23 < 2.6 > Wifi Network Confi guration Step 5. Select the appropriate network from the pull down menu of “ ESSID ”. Step 6. Select “ PSK “ from Authentication. For PEAP or TLS , please refer to < 2.13 > 802.1X authentication. UM-PPS-04-S-Q224V1 www.austin-hughes.com P.20...
  • Page 24 < 2.6 > Wifi Network Confi guration Step 7. Input “ Password ” for authentication. Step 8. Select “ DHCP ” to “ OFF ”. Default is “ ON ” Step 9. Click “ Apply ” to fi nish the above settings. Step 10.
  • Page 25 < 2.6 > Wifi Network Confi guration Step 11. Record the “ MAC address ” of the Wifi kit. Step 12. Assign an IP address of the Wifi kit from your DHCP server. UM-PPS-04-S-Q224V1 www.austin-hughes.com P.22...
  • Page 26: Login

    < 2.7 > Login In < Login >, you can login the PPS-04-S by “ Local User ” or “ Domain/LDAP ” login. ( Default login : “ Local User ” ) Local User : - Change “ Login name ” OR “ Password ” - Re-enter password in “...
  • Page 27 < 2.7 > Login In “ Domain Users Setting ”, - Click “ Update domain data ” to update domain user list. - Assign access right ( No access / Allow / Deny ) to “ Domain Users ” and click “ Apply ” . - The Domain User assigned “...
  • Page 28 < 2.7 > Login Domain/LDAP: - Default LDAP Authentication is “ Disable “ - Enable “ LDAP Authentication ” only when you want to login PPS-04-S by LDAP - Enter “ LDAP Server ” - Enter “ Port “. Default is “ 389 ” - Select “...
  • Page 29 < 2.7> Login In “ LDAP User Access ”, - Enter the Password of “ admin ” to update the user list. - Assign access right ( No access / Allow / Deny ) to “ User ” and Click “ Apply ” - The user assigned “...
  • Page 30: Snmp Setup

    < 2.8 > SNMP Setup PPS-04-S can manage the connected single & three phase intelligent PDUs in a single daisy-chain up to 32 levels via SNMP v1/v2 or v3 ( Simple Network Management Protocol ) ( I ). Accessing MIB Files Step 1.
  • Page 31 < 2.8 > SNMP Setup Step 5. Select the SNMP from the left navigation pane Step 6. The SNMP Settings window appears as below: Step 7. Click “ Enable “ in “ SNMP agent “ to start the SNMP agent service Step 8.
  • Page 32 < 2.8 > SNMP Setup The following steps summarize how to enable SNMP v3 support for PPS-04-S. Step 1. Connect one of the LAN port of Z series IP PDU to a computer Step 2. Open MS Edge Step 3. Enter the confi gured IP address into the address bar Step 4.
  • Page 33 < 2.8 > SNMP Setup Step 7. Click “ Enable “ in “ SNMP agent “ to start the SNMP agent service Step 8. Select “ v3 “ in “ SNMP version “ & the SNMP v3 settings window appears as below : Step 9.
  • Page 34 < 2.8 > SNMP Setup ( III ). SNMP Traps Setting After enable SNMP, you can click “ SNMP Traps “ to go to the “ SNMP Traps Setting “ page Below is the default setting for each PDU SNMP trap. You can set the SNMP trap option and Click “...
  • Page 35: Notifi Cation

    < 2.9 > Notifi cation In < Notifi cation > , you can confi gure the alarm email server & max. 5 email recipients to receive alarm notifi cations from PPS-04-S. Default is “ Disable ”. Step 1. “ Enable ” alarm email Step 2.
  • Page 36: Syslog

    < 2.10 > Syslog In < Syslog > , you can view the latest 2000 device and system log UM-PPS-04-S-Q224V1 www.austin-hughes.com P.33...
  • Page 37: Firmware Upgrade Of Z Series Ip Pdu

    < 2.11 > Firmware upgrade of Z series IP PDU < Firmware Upgrade > For function enhancement of PPS-04-S, please take the following steps to remotely upgrade the fi rmware of Z series IP PDU : Step 1. Click the following link to go to the mangement software download page : http://www.austin-hughes.com/resources/infrapower/software Step 2.
  • Page 38 < 2.11 > Firmware upgrade of Z series IP PDU Step 8. The fi rmware upgrade window appears as below : Step 9. Click “ Browse ” and select the fi rmware fi le (.enc ) from the specifi c path in the pop up window and Click “...
  • Page 39: Bulk Firmware Upgrade Of Z Series Ip Pdu

    < 2.12 > Bulk Firmware Upgrade of Z series IP PDU < Bulk Firmware Upgrade via DHCP/TFTP > If a TFTP server is available, you can use it to perform fi rmware upgrade for a huge number of Z series IP PDU the same network.
  • Page 40 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU Step 6. Reboot the Z series IP PDU. The DHCP server will execute the commands in the “ fwupdate.cfg” fi le on the TFTP server to upgrade those Z series IP PDUs supporting DHCP in the same network. You can Click “...
  • Page 41 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU Confi guration of username / password for bulk fi rmware upgrade Step 1. Access the SSH using putty Step 2. Input the login name and password to login the CLI. Step 3.
  • Page 42 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU Step 4. Select “ (5) Change fi rmware upgrade authentication ” and “ Enter ” Step 5. Select “ (1) Change authentication name ” or “ (2) Change authentication password ” to change the username or password for bulk fi...
  • Page 43 Windows Server 2019 Step 1. Add a new vendor class for Austin Hughes Z series IP PDU. - Right Click the IPv4 node in DHCP to select Defi ne Vendor Classes ( under server manager, select tools > DHCP - Click “...
  • Page 44 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU Step 2. Defi ne one DHCP standard option – Vendor Class Identifi er - Right Click the IPv4 node in DHCP to select Set Predefi ned Options. - Select “ DHCP Standard Options ” in the “ Option class ” fi eld, and “...
  • Page 45 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU - Click “ Add “ to add the fi rst option. Type “ update-server ” in the Name fi eld, select String as the data type, and type 1 in the Code fi eld and Click “ OK “. - Click “...
  • Page 46 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU - Click “ Add “ to add the fourth option. Type “ update-port ” in the Name fi eld, select String as the data type, and type 4 in the Code fi eld and Click “ OK “. Step 4.
  • Page 47 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU - Click “ Next “. - Select “ DHCP Standard Options “ in the “ Vendor class ” fi eld, select “ 060 Vendor Class Identifi er ” from the Available Options list, and type “ InfraPower ” in the “ String value ”...
  • Page 48 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU - Select “ 002 update-control-fi le ” from the Available Options list, and type the fi lename “ fwupdate.cfg ” in the “ String value ” fi eld. - Select “ 003 update-magic ” from the Available Options list, and type folder name of the fi les you stored in the root directory of the TFTP server in the “...
  • Page 49 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU - Select “ 004 update-port ” from the Available Options list, and type UDP port number you set for the TFTP server in the “ String value ” fi eld. Port number 69 is used in this illustration. - Click “...
  • Page 50 < 2.12 > Bulk Firmware Upgrade of Z series IP PDU Description of Devices.csv Column A & B is reserved for future use Column C is the MAC address of the network interface of the Z series IP PDU. As the Z series IP PDU comes with two network interface, we highly recommend to do the bulk fi...
  • Page 51: 802.1X Authentication

    < 2.13 > 802.1X authentication User Guide of 802.1X Authentication 802.1X is an authentication protocol which provides protected authentication for secure network access with the use of a Radius server. It opens ports for network access when an organization authenticates a user’s identity and authorizes them for access to the network.
  • Page 52 < 2.13 > 802.1X authentication Please follow the procedures below to setup the 802.1X authentication in PPS-04-S. < 802.1X authentication for Wired network > Step 1. Login the PPS-04-S and go the Network. Step 2. Click the Authentication pull down menu and you will see the authentication method. UM-PPS-04-S-Q224V1 www.austin-hughes.com P.49...
  • Page 53 < 2.13 > 802.1X authentication Step 3. To use PEAP as authentication method, select PEAP. Then input the “ Identity ”, “ Password ” and “ CA certifi cate ” in PEM format. You can uncheck “ Enable CA certifi cate ” to bypass the authentication using CA certifi...
  • Page 54 < 2.13 > 802.1X authentication < 802.1X authentication for Wireless network > Step 1. Login the PPS-04-S and go to Network. Click the Authentication pull down menu and you will see the authentication method UM-PPS-04-S-Q224V1 www.austin-hughes.com P.51...
  • Page 55 < 2.13 > 802.1X authentication Step 2. To use PEAP as authentication method, select PEAP. Select the Wireless network from “ ESSID ”, input the “ Identity ”, “ Password ” and “ CA certifi cate ” in PEM format. You can uncheck “ Enable CA certifi...
  • Page 56 < 2.13 > 802.1X authentication Step 3. To use TLS as authentication method, select TLS. Select the Wireless network from “ ESSID ”, input the “ Identity ”, “ Certifi cate ”, “ Private key ”, “ Private key password ” and “ CA certifi cate ”. ( Certifi...
  • Page 57: Command Line Interface Access

    < Section 3 > Command Line Interface ( CLI ) Access < 3.1 > Command Line Interface ( CLI ) Access Command Line Interface ( CLI ) allows you access the Z series IP PDU via Telnet or Secure Shell ( SSH ) to confi...
  • Page 58 Intentionally Left Blank UM-PPS-03-S-Q123V1 www.austin-hughes.com...
  • Page 59 Intentionally Left Blank UM-PPS-03-S-Q123V1 www.austin-hughes.com...
  • Page 60 The company reserves the right to modify product specifi cations without prior notice and assumes no responsibility for any error which may appear in this publication. All brand names, logo and registered trademarks are properties of their respective owners. Copyright 2024 Austin Hughes Electronics Ltd. All rights reserved. UM-PPS-04-S-Q224V1 www.austin-hughes.com...

Table of Contents