Uponor Combi Port E-Pro Series Installation And Operation Manual

Uponor Combi Port E-Pro Series Installation And Operation Manual

Heat interface unit

Advertisement

Quick Links

Combi Port E-Pro
EN
Installation and operation manual
SD0000339

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Combi Port E-Pro Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Uponor Combi Port E-Pro Series

  • Page 1 Combi Port E-Pro Installation and operation manual SD0000339...
  • Page 2: Table Of Contents

    Filling and flushing..............19 Tightness testing..............19 Visual inspection..............19 Operation................20 Start up the hydraulic system..........20 Uponor Combi Port E-Pro mobile application....... 22 Finishing the installation and hand over........ 24 Maintenance................ 25 General information.............. 25 Turning off heat interface unit..........25...
  • Page 3: Copyright And Disclaimer

    For any questions or queries, please visit the local Uponor website or speak to your Uponor representative. “Uponor” is a registered trademark of Uponor Corporation.
  • Page 4: Preface

    Risk of injury and damage. Ignoring warnings can cause components. personal injury and/or damage to products and other property. Uponor is not liable for damage caused by ignoring the instructions in this document or the applicable building code. Caution! Risk of malfunctions. Ignoring cautions can cause the 2.2 Standards and regulations...
  • Page 5 Please, recycle responsibly to support the sustainable use of resources and prevent possible harm to human health and/or the environment. Household users should contact the retailer where they purchased this product, or their local government office, for details on where and how they can take it for recycling.
  • Page 6: System Description

    3.1 Operating principle SD0000340 3.2 Functional description In the Uponor Combi Port E-Pro, the cold water is heated only when Domestic heating: The Uponor Combi Port E-Pro manages required in the flow-through principle via a stainless steel high- independently the hydraulic balancing between hot water and performance plate heat exchanger.
  • Page 7: Components

    Connection description Uponor Combi Port E-Pro UFH 3.4 Accessories Uponor offers a variety of accessories for use with the standard portfolio. The following accessories are optional. Their use completes the product portfolio. The application is described in more detail in the following chapters.
  • Page 8 Uponor Smatrix Wave Pulse Uponor Smatrix Base PRO CD0000271 Uponor Smatrix is a fully equipped range of components for room temperature control, optionally via radio or wired. The unique auto- balancing technology eliminates the need for manual balancing of the loops.
  • Page 9: Spare Parts

    Connection set 2nd heating circuit CD0000267 A connection set for 2 heating circuit can be connected on demand. Return temperature limiter (RL) CD0000754 A return temperature limiter (RL) can be connected on demand. The return temperature limiter has a setting scale printed on the handwheel.
  • Page 10: Prepare For Installation

    4 Prepare for installation 4.1 General information Warning! The fittings are under pressure. Escaping pressurized media can cause serious injury such as scalding or eye damage. Depressurise the system before performing any installation work. For retrofits to an existing system: Drain the system or close the supply lines of the section and depressurise it.
  • Page 11: Mechanical Installation

    Dismount the frame and door. The above installation example shows a typical installation with Store the frame and door for later mounting. Uponor Combi Port E-Pro in an in-wall cabinet with an underfloor heating manifold. Adjusting the in-wall cabinet A Uponor Smatrix controller for room temperature control is mounted and connected to the manifold.
  • Page 12 Install the in-wall cabinet Secure the in-wall mounting box to the wall recess, and secure with the enclosed hexagon bolts. Note For freestanding installations, set the height according to the table and adjust the feet accordingly. Pay attention to the horizontal alignment. Mark the hole positions in the wall recess.
  • Page 13 Install the heat interface unit Connecting the pipes Note Install the pipes in accordance with the planning documentation. Note Ensure the use of supplied seals when connecting the pipes! Connect the underfloor heating pipes to the manifold. SI0000291 Item Description Heat interface unit Hexagon nut (4 pcs) Fixed bolts...
  • Page 14: On-Wall Installation

    Close the heat interface unit with an insulation cover. Install the heat interface unit Attach the frame to the cabinet body using wing nuts. Mount the door in the frame by fitting the two frame brackets into the recesses in the door. 5.3 On-wall installation Note For disassembling the on-floor cabinet, leave 3 cm space...
  • Page 15: Install The Accessories

    Install the on-wall covering 5.4 Install the accessories Caution! Mount according to the condition of the walls and supports SI0000307 Item Description On-wall cover SI0000289 Close the heat interface unit with an insulation cover. Item Description Hang the on-wall cover on to the lateral strips of the base sheet. Circulation line Room temperature control Heating circuit (secondary, 2nd)
  • Page 16 Observe the flow direction and mount the return temperature limiter. Distance nut Fasten the distance nuts on the bolts. Fasten the DIN-rail with the screws on the distance nut. Attach the Uponor Smatrix room controller to the DIN-rail. Combi Port E-Pro Installation and operation manual...
  • Page 17: Electrical Installation

    6.1 Connecting the heat interface unit Connect the heat interface unit as follows: Connect the power supply to the Uponor Combi Port E-Pro in accordance with the wiring diagram, see the chapter "Wiring diagrams". Pull the battery protection foil on the right hand side of the heating station controller.
  • Page 18: Additional Installation

    7 Additional installation 7.1 Heat meter or cold/warm water Sensor pocket heat meter The sensor pocket (M10x1) is available for the flow sensor. The plug meter installed by the factory must be removed. Hot and cold water meters, and heat meters, can easily be installed Remove the plug with an internal hexagon key (6 mm).
  • Page 19: Strainer

    7.2 Strainer 7.4 Tightness testing Caution! Warning! Shut off the water supply to the unit and relieve the Leaks can cause personal injury and property damages. pressure before any work with the strainer. Note Caution! Pressure leaks may occur even at normal operating To open the cold water/primary flow strainer, use internal pressure and must be repaired immediately.
  • Page 20: Operation

    Please read the installation manual from the pump Hydraulic scheme manufacturer. The Uponor Combi Port E-Pro unit has an injection circuit. A backflow Observe the hydraulic diagram as an installation guide. preventer is mounted in the screw connection of the bypass valve.
  • Page 21 Uponor floor heating calculations Uponor Fußbodenheizungsberechnung Uponor vloerverwarmingsberekening Calculation du chauffage par le sol Uponor 1,5 L/min Calcolo riscaldamento a pannelli radianti Uponor Room heating circuit data Raum-Heizkreis-Daten Ruimte- en verwarminggroepsgegevens Données des pièces - circuits de chauffage Dati circuito riscaldamento locale Room No.
  • Page 22: Uponor Combi Port E-Pro Mobile Application

    Scan the QR code available on the Uponor Combi Port E-Pro Connection status controller. Settings Press the blue button in the middle of the Uponor Combi Port E- Pro controller until it flashes. Continue in the App. Hot water Helptexts and guidance is available in the app.
  • Page 23 Hot water temperature • Hot water flow • Cold water temperature • Performance Combi Port E Uponor Combi Port E Settings Time and date D Circulation Settings Back Automatically set the current time and date of the controller when connecting.
  • Page 24: Finishing The Installation And Hand Over

    Screed drying program F Heating • Start up, step by step DISPLAYED VALUES • Software version • Controller type Combi Port E Heating Uponor Combi Port E Operation Heating Back 8.3 Finishing the installation and Status Operation hand over Status 35.5°C 31.5°C 35.5°C...
  • Page 25: Maintenance

    9 Maintenance 9.1 General information 9.2 Turning off heat interface unit Note Important information If droplets of water are detected, call a qualified service personnel. Read and obey these instructions to ensure the safe and correct operation. This increases the reliability and lifespan of the system. The ball valves must be closed in the event of malfunctions.
  • Page 26: Troubleshooting

    10 Troubleshooting 10.1 Fault description Fault description Cause Solution Hot water function Hot water temperature too low or volatile Central heating Buffer temperature too low Buffer temperature must be 5-10 K above hot water setpoint Heating circuit pump type not supported The following pump type is supported: Grundfos UMP3 Setting for heating circuit pump is not correct...
  • Page 27: App Alarms

    Buffer storage tank is not filled Check the buffer storage tank filling 10.2 App alarms Alarms occuring in the Uponor Combi Port E-Pro app are described directly in the app instead of in this installation and operation manual. Combi Port E-Pro...
  • Page 28: Technical Data

    Valve cold water Pipes 1.4404 (X28) Control signal Valve heating 1 Control signal Black Valve heating 1 Uponor Vario S manifold Value Medium Heating water according to VDI 2035 Operating temperature 5-60 °C DC input 12 V power supply (ESBE Operating pressure...
  • Page 29: Data Output

    Contacts Description Marking Contacts Description Marking (X23) Measurement signal Room thermostat (X13) Earthing on site RS485 for Modbus/terminal (X24) Measurement signal Outdoor temperature ⊥ Earthing on site RS485 for Modbus/terminal sensor B signal RS485 for Modbus/terminal A signal RS485 for Modbus/terminal Flow sensor input Contacts Description...
  • Page 30: Wiring Diagrams

    11.4 Wiring diagrams Uponor Combi Port E-Pro with Uponor Base flexiboard 230 V X2 LO N N L L’ N L L’ N L L’ N L L’ N L L’ N L L’ N L L’ N L L’...
  • Page 31 Description of connection symbols For a description of the connection symbols, see chapter System Item Description description, Components, Connection description. Motor valve Uponor Combi Port E-Pro controller Flow sensors Plate heat exchanger Contact Description Colour cable Hot water meter distance piece...
  • Page 32 Uponor Combi Port E-Pro with Uponor Smatrix Wave Pulse 230 V X2 LO N T-166 T-168 T-165 T-163 T-169 L L’ PUMP BOILER Fuse < > T3.15A Power 24 V Combi Port E-Pro Installation and operation manual...
  • Page 33 Uponor Smatrix room thermostats (wireless) (optional) EPP cover Outdoor temperature sensor Uponor Smatrix Wave Pulse room controller Zone valve for limiting heating flow to the flat Potential free heat circuit distributor cable (optional) Plug-in power supply 230 V Combi Port E-Pro...
  • Page 34 Uponor Combi Port E-Pro with Uponor Smatrix Base Pulse 230 V X2 LO N T-141 T-143 T-144 T-145 T-146, T-148 T-149 A B + - A B + - A B + - A B + - A B + - A B + - L L’...
  • Page 35 Uponor Smatrix room thermostats (wireless) (optional) EPP cover Outdoor temperature sensor Uponor Smatrix Base Pulse room controller Zone valve for limiting heating flow to the flat Potential free heat circuit distributor cable (optional) Plug-in power supply 230 V Combi Port E-Pro...
  • Page 36 Uponor Combi Port E-Pro with single room thermostat 230 V X2 LO N WD0000079 Description of wiring diagram Item Description Room thermostat RTA Item Description EPP cover Motor valve Plug-in power supply 230 V Uponor Combi Port E-Pro controller Plate heat exchanger...
  • Page 37: Dimensional Drawings

    Heating return (primary) Blue Room temperature sensor (optional) Outdoor temperature sensor 11.5 Dimensional drawings All dimensions are given in mm. Uponor Combi Port E-Pro UFH 901.5 849.5 22.85 151.5 In-wall cabinet 750 x 1200 Uponor Combi Port E-Pro RC ZD0000017...
  • Page 38: Performance Curves

    On-wall cabinet 11.6 Performance curves Pressure drops with 24 plates Heating side (primary) 0.80 0.70 0.60 0.50 0.40 0.30 0.20 ZD0000016 0.10 0.00 1150 1170 1000 1100 1200 Item Description Pressure drop in bar Primary heating demand in litres/hour (l/h) Max range Rails with ball valves Pressure drops including ball valve.
  • Page 39 Primary heating demand and return Cold water warming 40 K (10-50 °C) temperatures with heat exchanger 24 plates 55 °C 60 °C 65 °C 1200 1100 70 °C Cold water warming 35 K (10-45 °C) 1000 75 °C 80 °C 85 °C 50 °C 55 °C...
  • Page 40 Cold water warming 45 K (10-55 °C) Cold water warming 50 K (10-60 °C) 60 °C 65 °C 70 °C 65 °C 70 °C 75 °C 1200 1200 80 °C 75 °C 1100 1100 85 °C 80 °C 1000 1000 85 °C Item Description...
  • Page 41 Pressure drops with 40 plates Primary heating demand and return temperatures with heat exchanger 40 Heating side (primary) plates Cold water warming 35 K (10-45 °C) 0.80 0.70 50 °C 1600 55 °C 0.60 1400 0.50 60 °C 1200 65 °C 0.40 1000 70 °C...
  • Page 42 Cold water warming 40 K (10-50 °C) Cold water warming 45 K (10-55 °C) 55 °C 60 °C 60 °C 65 °C 1600 1600 70 °C 1400 1400 65 °C 75 °C 1200 1200 70 °C 80 °C 75 °C 1000 1000 85 °C...
  • Page 43 Cold water warming 50 K (10-60 °C) 65 °C 70 °C 1600 75 °C 1400 80 °C 1200 85 °C 1000 Item Description Primary heating demand in litres/hour (l/h) Primary heating supply temperatures Tapping capacity in litres/minute (l/min) Max range Tapping capacity 65 °C 70 °C...
  • Page 44 Uponor GmbH Industriestraße 56, D-97437 Hassfurt, Germany Uponor reserves the right to make changes, without prior notification, 1143309 v2_05-2024_EN to the specification of incorporated components in line with its policy of www.uponor.com Production: Uponor/DCO continuous improvement and development.

Table of Contents