Installation & Operation Manual Wireless Thermostat Model NRC-10R...
Page 3
Copyright information • Navien UK Ltd. All rights reserved. • Wi-Fi®, the Wi-Fi CERTIFIED logo, and the Wi-Fi logo are registered trademarks of the Wi-Fi Alliance. • Trademarks and trade names used in this manual are the property of their respective owners.
Page 4
You may damage the device. _ Any attempt to disassemble or repair the device Indicates a potentially hazardous situation which, if voids Navien’s Limited Warranty. Navien is not not avoided, could result in injury or death. responsible for damage or injuries caused by voiding the Navien’s Limited Warranty.
Page 5
WARNING CAUTION • Avoid interference with other electronic devices. • Use suitable tools and appropriate force to install _ The device emits radio frequency (RF) signals the device. that may interfere with unshielded or improperly Using unsuitable tools or excessive force during shielded electronic equipment, such as installation may damage the device.
Contents Overview ..........7 Using the central heating system ..20 Included items ...........9 Adjusting the central heating temperature ..20 Device layout ...........10 Selecting the central heating mode ....21 About the LCD screen icons ......11 Setting the central heating program (Schedule settings) ..........22 Installing the wireless thermostat ..
Page 7
Setting the user configurations ..34 Error Code Guide ....... 45 Selecting 12H 24H format ........34 Recycling and disposal ...... 46 Setting the installer configurations ..35 Recycling the package ........46 Changing the zone number ......35 WEEE: Recycling or disposing of the device and its parts .............46 Calibrating the indoor temperature ....36 Testing the RF signal ........37...
Overview Navien Smart Plus uses 2-way communication on an 868 MHz radio frequency (RF) band to control the heating system. The wireless communication module (BCM-41RW or BCM-45RW) operates as the control centre of the system, and the Navien boilers (LCB Range (Oil) or NCB Range (Gas)) support 2-wire communication (KIW) technology. It is possible to control it using a 2-wire connection from the BCM-41RW or BCM-45RW terminals.
Page 9
Zone2 Zone3 Zone1 NRC-10R LCB Range (Oil) NCB Range (Gas) VCU-10R Comm Wi-Fi BCM-41RW BCM-45RW Navien boiler • This device specifications or contents of this manual may be changed without prior notice due to upgrade of device functions. • The device functions can be limited by the operating environment.
Included items Open the packaging and ensure that the following items are provided. Wireless thermostat Screws and anchors Table stand Wall mounting plate AA Alkaline 1.5 V batteries Installation & Operation manual...
Device layout Name Description The following table provides brief information on each Displays functions and current part of the wireless thermostat. screen status. Press to set program schedules Program for the central heating or button domestic hot water system. Info Press to display operation and button program information.
The outdoor temperature thermostat. compensation function can be enabled via the Indicates the RF Outdoor RF signal Navien Smart Plus app. communication signal temperature strength If the boiler performs strength. compensation the outdoor temperature Indicates that the...
Page 13
Icon Name Description Icon Name Description Indicates that the Displays the current Days central heating or direct day. Combustion hot water system is in Displays the current combustion. and set temperature, Information total usage time, Indicates that the boiler Eco mode and amount of oil is in Eco mode.
Page 14
Icon Name Description Displays the set domestic hot water (DHW) mode. • AUTO: The set program mode for DHW is on. • ON: DHW is on. • ONCE: The Domestic once function is hot water enabled. operation • OFF: DHW is off. •...
Installing the wireless thermostat Inserting the batteries You can place the wireless thermostat on a stable, flat surface using the supplied table stand or install the Before installing the wireless thermostat, insert the wireless thermostat on a wall using the supplied wall supplied AA Alkaline 1.5 V batteries into the back of the mounting plate.
Placing on a table • The normal working life of the battery is approximately 1 year. However, battery Check the direction of the table stand and attach it to life may vary depending on conditions, the back of the wireless thermostat. environmental factors, functions of the You will hear a "click"...
Attaching the wall mounting bracket Hang the wireless thermostat on the wall mounting plate by aligning the hooks. Check the direction of the wall mounting plate and You will hear a "click" sound when the wireless affix it to the wall using four screws. thermostat is securely hung.
Selecting the zone number Before pairing with the communication module, enter Press the Enter button to confirm the zone number. RF pairing mode for the wireless communication The wireless thermostat will be paired with the module, and then set the zone number for the wireless wireless communication module automatically.
Pairing with the wireless communication module If the wireless thermostat is not automatically paired On the wireless thermostat, press and hold the with the wireless communication module after selecting Program and Enter buttons simultaneously for 3 and confirming the zone number for the wireless seconds to enter pairing mode.
Page 20
On the wireless communication module, exit RF paring mode after completing pairing all the wireless thermostats with the wireless communication module, and then check if the RF signal strength icon ( ) is displayed on the wireless thermostat LCD screen. If the RF signal strength icon ( ) is not displayed, pair the wireless thermostat with the wireless communication module again.
Using the central heating system Adjusting the central heating Rotate the encoder up or down to select the desired temperature central heating temperature. Adjust the central heating temperature for the selected zone. In normal operation mode, press the HEAT button. The set temperature will be displayed on the LCD screen.
Selecting the central heating mode To select BOOST mode, press and hold the HEAT button. Each central heating mode is explained in the following You can select the various central heating system modes table. for the selected zone. To select a central heating mode, press the HEAT button sequentially to select the desired central heating mode (AUTO, ON, and OFF).
Setting the central heating program Press the HEAT button to enter CH Program mode. The days of the week will blink on the LCD screen. (Schedule settings) If you set a central heating program (Schedule settings), you can select the desired day and time to operate the central heating system.
Page 24
Rotate the encoder up or down to select the Program Mon to Sat and weekday, and then press the Enter button to confirm number temperature 06:00 07:00 20℃ 09:00 09:00 15℃ 12:00 12:00 20℃ 13:00 14:00 15℃ Program Info Back Enter 17:00 16:00...
Page 25
Rotate the encoder up or down to select the central Rotate the encoder up or down to select the central heating temperature for each selected program, and heating starting minute, and then press the Enter then press the Enter button to confirm it. button to confirm it.
Using the domestic hot water (DHW) Selecting the domestic hot water mode Each domestic hot water mode is explained in the following table. You can select the various domestic hot water modes for a selected zone. To select a domestic hot water mode, press the DHW button sequentially to select the Name Description...
Setting the domestic hot water program Press the DHW button to enter DHW Program mode. (Schedule settings) The days of the week will blink on the LCD screen. If you set a program (Schedule settings), you can select the desired day and time to operate the domestic hot water system.
Page 28
Rotate the encoder up or down to select the Rotate the encoder up or down to select the number weekday, and then press the Enter button to confirm of the programs to use (up to six programs), and then press the Enter button to confirm it. Program Info Back Enter...
Page 29
Rotate the encoder up or down to select ON or OFF Rotate the encoder up or down to select the to use the domestic hot water for each of selected domestic hot water starting minute, and then press programs, and then press the Enter button to the Enter button to confirm it.
Viewing basic information You can view information about the use of the central Each information item is explained in the following heating and domestic hot water on the LCD screen. table. Press the Info button, and then rotate the encoder up or down to change the information items.
Using advanced functions The wireless thermostat provides advanced functions Item Description with various modes, such as child-lock mode, holiday Displays the total operation mode, pre-heat function (Central heating), and freeze Total operation time of both central heating protection for safety and unit protection. time and domestic hot water.
To deactivate child-lock mode, press and hold the Rotate the encoder up or down to select 1 (Holiday Program and Info buttons simultaneously until the mode), and then press the Enter button. child-lock icon ( ) disappears on the LCD screen. Using holiday mode If you are away from home for a long holiday and do not need to use the boiler for an extended period, activate...
Using the pre-heat function Rotate the encoder up or down to select 2 (Pre-heat (Central heating) function), and then press the Enter button. If you activate the pre-heat function, pre-heating will be activated to provide the optimum temperature ten minutes before the set program time during AUTO mode.
Using the freeze protection function Rotate the encoder up or down to select 3 (Freeze protection function), and then press the Enter If you activate the freeze protection function, you can button. protect the boiler from freezing. If freeze protection is set in boiler, then it is not activated by thermostat.
Setting the user configurations Selecting 12H 24H format Rotate the encoder up or down to select 4 (Time format settings), and then press the Enter button. You can select the desired time format to display on the LCD screen. Press and hold the Back and Enter buttons simultaneously to open the User setting menu.
Setting the installer configurations Changing the zone number Rotate the encoder up or down to select 1 (Zone number settings), and then press the Enter button to In the Installer setting menu, you can change the zone confirm it. number after having selected and confirmed it. Press and hold the Info and Enter buttons simultaneously to open the Installer setting menu.
Calibrating the indoor temperature Rotate the encoder up or down to select a desired zone number from [1] to [3], and then press the In the Installer setting menu, you can calibrate the Enter button to confirm it. indoor temperature. Press and hold the Info and Enter buttons simultaneously to open the Installer setting menu.
Testing the RF signal Rotate the encoder up or down to select 2 (Temperature calibration), and then press the Enter After pairing the wireless thermostat with the button to confirm it. communication module, you can test the RF signal between the wireless thermostat and the communication module.
Setting the program day Rotate the encoder up or down to select 3 (RF signal test), and then press the Enter button. The default day settings for Program mode is 7 days. In the Installer setting menu, you can change the program day settings 5+2 days (weekday, weekend) or 5+1+1 days (weekday, Saturday, Sunday).
Page 40
Rotate the encoder up or down to select 4 (Program Rotate the encoder up or down to select 1 (7 days), 2 setting mode), and then press the Enter button to (5+2 days), 3 (5+1+1 days), and then press the Enter confirm it.
Setting the date and time Press and hold the Info and Enter buttons simultaneously to open the Installer setting menu. In the Installer setting menu, you can set the date and time manually. • The date and time on the LCD screen is automatically updated via the Wi-Fi network, if the communication module is connected to the Wi-Fi network.
Resetting the accumulated fuel usage Rotate the encoder up or down to select the desired year, and then press the Enter button to confirm it. and operation time In the Installer setting menu, you can reset the Rotate the encoder up or down to select the desired accumulated fuel usage and operation time.
Resetting the wireless thermostat Rotate the encoder up or down to select 6 (Accumulated fuel usage and operation time reset), In the Installer setting menu, you can reset the all the and then press the Enter button to confirm it. data, including set program data.
Page 44
Rotate the encoder up or down to select 7 (Factory reset), and then press the Enter button to confirm it. Program Info Back Enter Rotate the encoder up or down to select OFF or ON, and then press the Enter button to confirm it. Program Info Back Enter...
Troubleshooting Before reporting a malfunctioning device, refer to the following table and see if you can identify and fix the problem. Fault situation Suggested remedies • Check if the communication module is in pairing mode when attempting to pair with the communication module. The wireless thermostat cannot be paired •...
Error Code Guide When an error code appears on the LCD screen, refer to the following table for a definition and possible remedy for the situation. Error code Reason Self-diagnostic / Action E001 Displays when a boiler lock out has occurred. Resolve the boiler’s error.
Recycling and disposal Recycling the package Sort out the waste to separate that which can be recycled (cartons, plastics, etc.) from the various wastes that cannot be recycled (straps, etc.). Also recycle the product’s packaging in accordance with all relevant local regulations. WEEE: Recycling or disposing of the device and its parts •...
Warranty Manufacturer's warranty of 2 years is provided. This warranty does not cover damage caused by mishandling such as accidental drops or collisions.
• There is a risk of explosion if the battery is replaced using an incorrect type. • Dispose of used batteries according to the instructions. Supplier's name: KDNA (KYUNGDONG NAVIEN CO., Ltd.) Supplier's model identifier: NRC-10R (Wireless thermostat) ErP control...
Page 50
• This product’s safety/RF/EMC have already been tested by a qualified laboratory and received passing marks, but any abnormal operation method or conditions may make the product stop working or experience a malfunction. Manufactured by KDNA (KYUNGDONG NAVIEN CO., Ltd.) www.kdnavien.co.kr Certification...
Need help?
Do you have a question about the NRC-10R and is the answer not in the manual?
Questions and answers