KX-TC1232JXB CONTENTS Page Page 1 STANDARD BATTERY LIFE 7.7. Check Battery Charge 1.1. Battery Strength 7.8. Check Link 1.2. Recharge 7.9. Check Handset Transmission 1.3. Battery Information 7.10. Check Handset Reception 1.4. Battery Replacement 7.11. Check Call ID 1.5. Standby mode (While the handset is off the base unit) 7.12.
Page 3
KX-TC1232JXB 13.5. Waveform of DATA used for cordless transmission and 21 CABINET AND ELECTRICAL PARTS LOCATION (BASE UNIT) reception 14 BLOCK DIAGRAM (BASE UNIT) 22 CABINET AND ELECTRICAL PARTS LOCATION (HANDSET) 64 15 CIRCUIT OPERATION 23 ACCESSORIES AND PACKING MATERIALS 15.1.
The battery strength is as shown in the chart below. 1.2. Recharge 1.3. Battery Information After your Panasonic battery is fully charged: Operation Operating time While in use (TALK) Up to about 6 hours While not in use (Standby)
KX-TC1232JXB 1.4. Battery Replacement 1.5. Standby mode (While the handset is off the base unit) The handset goes into the standby mode after you finish using the handset (making/answering a call, viewing the Caller List or directory list etc.). The display is blank, but the handset can receive calls. The battery operating time is conserved in this mode.
3 CONNECTION 1. Connect as shown. • USE ONLY WITH Panasonic AC ADAPTOR PQLV14BXZ. • The AC adaptor must remain connected at all times. (It is normal for the adaptor to feel warm during use.) • If your unit is connected to a PBX which does not support Caller ID services, you cannot access those services.
KX-TC1232JXB 3.1. Adding Another Phone This unit will not function during a power failure. To connect a standard telephone on the same line, use the Panasonic T- adaptor.
KX-TC1232JXB 4 OPERATIONS 4.1. Displays Both the handset and the base unit show you information and instructions on their displays. These display prompts are shown below. Handset display...
KX-TC1232JXB 4.4. Automatic Answering Operation When the unit answers a call, a greeting message is played and the caller´s message is recorded. Setting the Unit to Answer Calls...
KX-TC1232JXB 4.5. Listening to Messages You can see the total number of recorded messages on the base unit display. If the ANSWER ON indicator flashes, new messages have been recorded. During playback...
Page 20
KX-TC1232JXB From the Handset If someone else is in the room and you want to listen to the recorded messages privately, you can use the handset.
KX-TC1232JXB 7.12. Bell Reception Cross Reference: NOTE: Telephone Line Interface (P.52). DSP is IC301. Check Link (P.32) Cross Reference: Check Link (P.32)
KX-TC1232JXB 8 ADJUSTMENTS (BASE UNIT) If your unit have below symptoms, adjust or confirm each item using remedy column from the table. Symptom Remedy The base unit dose not respond to a call from handset. Make adjustments in item (A) The base unit dose not transmit or the transmit frequency is off.
KX-TC1232JXB 8.2. How to Set the Test Mode Remove the antenna lead wire from P.C.Board of the base unit. CH10 Test mode 8.3. Adjustment Replace Adjustment Items Test Mode Adjustment Point Procedure Parts • Adjust T401 so that the reading of the Digital Voltmeter is 1.7V ± 0.1V. IC401, (A) RX VCO CH10 Talk...
8.4. Adjustment Standard (Base Unit) TX Power Spectrum FM Deviation Analyzer (D) Meter (G) SP-OUT Rx Sense. TX Freq Frequency DC12V AF Volt Meter AF_OSC 2 RF Volt Counter (C) RFTX TXGND Meter (E) RFRX RF_S.S.G. IFGND IFOUT 8Ω RXGND 49.97MHz TXVCO TXGND...
KX-TC1232JXB 9 ADJUSTMENTS (HANDSET) If your unit have below symptoms, adjust or confirm each item using remedy column from the table. Symptom Remedy The movement of Battery Low Indicator is wrong. Make confirmation in item (A) The base unit does not respond to a call from handset. Make adjustment in item (B) The base unit does not transmit or the transmit frequency is off.
KX-TC1232JXB 9.2. How to set the test mode CH10 Test Mode * Refer to CIRCUIT BOARD (HANDSET) (P.85). R608: 0Ω resistor 9.3. Adjustment Replace Adjustment Items Test Mode Adjustment Point Procedure Parts IC801 (A) Battery Low CH10 Talk 1. Set the power supply voltage to DC3.60V, and confirm so that the reading Confirmation of oscilloscope is High.
9.4. Adjustment Standard (Handset) SP LEVEL FM Deviation MIC-INPUT Meter (I), (J) Oscilloscope (H) RF_S.S.G. TX Power 44.2 MHz Spectrum Generator Analyzer (E) RXGND RFRX AF Volt Meter TX Freq Frequency Counter (D) 47µF 150Ω TX POWER TXGND Dummy Battery RXGND RXVCO TXGND...
KX-TC1232JXB 10 RF SPECIFICATION 10.1. Base Unit Item Value Refer to -. Remarks TX Frequency 44.200 MHz ± 0.7kHz ADJUSTMENTS (BASE UNIT) (C) at CH10 TX Power More than 10dBm (CH10) ADJUSTMENTS (BASE UNIT) (D) at CH10 Line Modulation factor 2.9 kHz~3.3 kHz ADJUSTMENTS (BASE UNIT) (G) Line Modulation factor (Max.)
KX-TC1232JXB 13.4. Ports for transmitting and receiving of data Handset: Base Unit: transmitting (TX)... 33 Pin transmitting (TX)... 97 Pin receiving (RX)... 27 Pin receiving (RX)... 59 Pin 13.5. Waveform of DATA used for cordless transmission and reception The DATA which is transmitted from the Handset to the Base Unit is combination of DATA 0, DATA 1, DATA Delimit. The DATA which is transmitted from the Base Unit to the Handset is combination of DATA 0, DATA 1, DATA Delimit.
14 BLOCK DIAGRAM (BASE UNIT) ANTENNA RF FILTER CF401, CF402 Telephone Line Interface 10.7MHz 455kHz TEL LINE AMP TEL LINE SW DIODE BRIDGE TEL LINE RX_DUP Q110 Q103, Q104 D103 DUP401 RF IC IC401 RX VCO PLL -DATA X401 -CLK T401 Q112 DC IN...
KX-TC1232JXB 15 CIRCUIT OPERATION 15.1. Outline Base unit consists of the following ICs as shown in BLOCK DIAGRAM. • CPU:IC301 − Controlling the whole system − Caller ID analyzing circuit (FSK, DTMF) − Flash memory control for Digital TAM memory −...
KX-TC1232JXB 15.3. Reset Circuit After power supply from AC adaptor, the VDD (5.6V) is input to Reset IC for making reset signal. Refer to the below waveform. <Fig. 101> <Fig. 102>...
KX-TC1232JXB 15.4. Charge Circuit Circuit Operation: When charging the handset on the base unit, the charge current is as follows; DC+(12V) → REG201 → CHG (Base) → [CHG1 (Handset) → D701 → BAT1..Battery..BAT2 (GND) → R705 → D708 → CHG2 (Handset)] → CHG2 (Base) → L202 → R204 → DC-(GND), In this way, the CPU on both unit detects the fact that the battery is charged.
KX-TC1232JXB 15.5. Telephone Line Interface Function: • Bell signal detection • ON/OFF hook and pulse dial circuit • Side tone circuit • Auto-disconnect circuit/Parallel connection detection circuit Bell signal detection and OFF HOOK circuit: In the idle mode, Q103 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the Tip (T) and Ring (R) leads (When the telephone rings), the AC ring voltage is transferred as follows: T →...
KX-TC1232JXB 15.6. Transmitter/Receive Circuit Base Unit and Handset are mainly consists of RF IC and CPU. Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency. 15.6.1. Transmitter Circuit Circuit Operation: The voice signal input from the TEL LINE interface goes to RF IC through CPU (CDL-OUT) to VOL402. And the signal goes through the compressor and SPLATTER FILTER of RF IC, it is output to transmitter circuit.
KX-TC1232JXB 15.8. Calling Line Identification Circuit (Caller ID) Function: The caller ID is a chargeable ID which the user of a telephone circuit obtains by entering a contract with the telephone company to utilize a caller ID service. For this reason, the operation of this circuit assumes that a caller ID service contract has been entered for the circuit being used.
KX-TC1232JXB 15.9. CPU Operation It goes into each operation mode because CPU controls the following ports. <Fig. 108> Moreover, it becomes the following charts by pushing the “TALK” button of Handset. <Fig. 109>...
KX-TC1232JXB 17 CIRCUIT OPERATION (HANDSET) 17.1. Outline Handset consist of the following ICs as shown in BLOCK DIAGRAM. • CPU: IC601 − All data signals (forming/analyzing ACK or CMD signal*) − All interfaces (ex; LED, Key, Buzzer, Detector Circuit, Charge, Battery Low) •...
KX-TC1232JXB 17.3. Battery Low Detector Circuit Circuit Operation: When the battery voltage goes down less than 3.57 V, this level is detected by the inside of RF IC (SIG-IN). The CPU detects this level and “ : Recharge battery” starts flashing. The RF IC check the level of the battery, if this level is less than 3.3 V, the output of RF IC (P-DOWN) becomes low level, then CPU stops working to keep memory.
KX-TC1232JXB 25 REPLACEMENT PARTS Ref. Part No. Part Name & Description Remarks PQKM10501Z1 UPPER CABINET LIST PQQT22258Y TAM LABEL PQSA10092Y ANTENNA This replacement parts list is KX-TC1232JXB only. PQSX10183Z RUBBER SWITCH, 20KEY PQSX10184Z RUBBER SWITCH, TAM KEY 1. RTL (Retention Time Limited) PQUS10285Z HOOK SPRING Note:...
Page 68
KX-TC1232JXB Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks L306 PQLQR1RS102 COIL R145 ERJ3GEYJ222 2.2k L307 PQLQR1RS102 COIL R201 ERDS2TJ271 L308 PQLQR1RS102 COIL R202 ERJ3GEYJ334 330k L309 PQLQR1RS102 COIL R203 ERJ3GEYJ104 100k L311 PQLQR2KA213 COIL...
Page 69
KX-TC1232JXB Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks R506 ERJ3GEYJ102 C330 ECUV1H101JCV 100P R507 ERJ3GEYJ101 C331 ECUV1H101JCV 100P R508 ERJ3GEYJ101 C332 ECUV1H101JCV 100P R509 ERJ3GEYJ222 2.2k C333 ECUV1H101JCV 100P R511 ERJ3GEYJ153 C334 ECUV1H101JCV 100P...
KX-TC1232JXB 26 FOR SCHEMATIC DIAGRAM 26.1. Base Unit (SCHEMATIC DIAGRAM (BASE UNIT)) 1. DC voltage measurements are taken with an oscilloscope or a tester with a ground. 2. The schematic diagrams and circuit board may be modified at any time with the development of new technology. Important Safety Notice: Components identified by mark have special characteristics important for safety.
Need help?
Do you have a question about the KX-TC1232JX and is the answer not in the manual?
Questions and answers
How can i manage the numbervof rings before auto answer or activating the recorded message