Important Pre-installation Considerations

Warning: Always ground yourself and/or use a ground strap before touching the RAID controller
or the RSBBU. Perform all installation work at an ESD-safe workstation. Use an ESD-safe Phillips
screwdriver set to a maximum torque of 2.25 inch pounds, and be sure the screwdriver is centered
in the screw to avoid damaging the screw head. If you exceed the maximum torque specification,
you may damage the board, connectors, or screws, and you will void the warranty of the board.
The batteries in the RSBBUs must recharge for at least six hours during fast charge under normal
operating conditions.
To protect your data, Intel recommends that you set the RAID controller Write Policy to write-
through until the battery unit is fully charged. When the battery unit is charged, you can change the
Write Policy to write-back to take advantage of the performance improvements of data caching.
The maximum ambient temperature for the battery pack is 45°C. Note: The temperature of the
battery pack is generally 15–20 degrees higher than the ambient temperature during fast charge.
Therefore, to complete the fast charge cycle, ambient temperature should be less than 45°C. If the
ambient temperature exceeds 45°C, the fast charge cycle will terminate prematurely, thus
preventing the battery pack from reaching a fully charged state.

Step-by-step AXXRSBBU4 Installation

Follow the steps in this section to install the AXXRSBBU4 on the Intel® RAID Controller
SRCSATAWB, SRCSASRB, or SAS Riser card.
A. If the RAID controller is already installed in a computer, follow these steps to remove it before
you install the AXXRSBBU4:
1
Shut down the computer, turn off the power, and unplug the power cord(s).
2
Remove the cover from the computer and ground yourself before touching the RAID
controller. Carefully unplug all cables going to the RAID controller. On the data cables,
depress the silver spring at the connector end to make sure the 2 tiny catches release.
3
Following the instructions in User's Guide for your server, carefully remove the RAID
controller from its slot. On the Intel® Server Platform S7000FC4UR, you must remove the
processor air baffle and push back on the guide latch while pulling up on the riser card.
4
Place the RAID controller on a flat, clean, static-free surface.
B. Follow these steps to install the AXXRSBBU4 on the RAID Controller.
1. Ground yourself, and remove the AXXRSBBU4 from the package.
2. Insert the battery pack harness connector (4 in Figure 2-1) at the end of the colored wires into
the 5-pin J2 connector (5 in Figure 2-1) on the backside of the AXXRSBBU4.
3. Make sure the 3 standoffs and 6 screws and the Phillips screwdriver are easily available
during the following steps.
4. Remove the protective metal cover from the battery connector on the RAID controller card.
(J7 on the Intel® SRCSATAWB and Intel® SRCSASRB.)