Summary of Contents for Thetford Marine TECMA DESIGN LINE
Page 1
DESIGN and FLEXI LINE Toilette Maceratrici Macerator Toilets Mazerationstoiletten Sanitaires dilacérateurs ISTRUZIONI DI INSTALLAZIONE ED USO INSTRUCTIONS FOR INSTALLATION AND USE AUFSTELLUNGS UND GEBRAUCHSANLEITUNG INSTALLATION ET MODE D’EMPLOI ...
Design and Flexi Line | instructions for installation and use | ENG ENGLISH INDEX INSTRUCTIONS FOR INSTALLATION AND USE GENERAL WARNINGS TO THE USER .................. 41 TECMA SANITARY SYSTEM ..................... 42 Warranty ........................ 42 Cleaning ........................ 43 Winterising ...................... 43 Toilet seat cover ..................... 43 Choosing the type of toilet paper ................ 43 OPERATING THE SYSTEM .................... 44 All‐in‐one control panel .................. 44 One button ...................... 44 Two buttons .................... 44 ...
Page 3
Design and Flexi Line | instructions for installation and use | ENG Floor fixation...................... 58 Solenoid valve ...................... 59 Inlet pump ...................... 60 CUT‐OUT control panels .................. 60 Cut out for All‐in‐One control panel: ............... 60 Cut out for Multiframe control panel: ............. 61 Cut out for Touch SFT control panel: ............... 61 Tank sensors ...................... 62 Pressure switch .................... 62 Field‐Effect ...................... 62 Equipment required .................... 63 ...
Page 4
Design and Flexi Line | instructions for installation and use | ENG A.3.4. Multiple Single System Wiring / Cablaggio Impianto Singolo Multiplo ..... 151 A.3.5. Centralized Fresh Water System / Impianto Centralizzato Acqua Dolce ... 152 A.3.6. Centralized Fresh Water Wiring / Cablaggio Centralizzato Acqua Dolce ... 153 12 V/24 V with All In One Switch ............... 153 12 V/24 V with Multiframe Switch ............. 154 12 V/24 V with Touch SFT Wall Switch ............ 155 110 V/230 V with All In One Switch ............ 156 A.3.7. Sensors Connection Guide / Guida alla Connessione dei Sensori ...... 157 ...
Design and Flexi Line | instructions for installation and use | ENG GENERAL WARNINGS TO THE USER WARNING: Read and understand the warnings listed in this document before installing, using, or servicing the system. Failure to comply with these warnings may cause malfunctions, injuries, damage, loss of the property, and electrocution. Any modification applied to Tecma's product may result in loss of the property, injuries, or electrocution. WARNING: Children should not play with the equipment. This equipment can be used by children aged 8 and up if under surveillance, or if they have received the instructions regarding use of the device safely and if they understand dangers involved. Cleaning and maintenance by the user should not be performed by children unless they are older than ...
Design and Flexi Line | instructions for installation and use | ENG 1. TECMA SANITARY SYSTEM Tecma marine sanitary systems are made in Italy. The entire production is made in the district of Civita Castellana, which is well known for manufacturing top‐quality ceramic sanitary ware. The Tecma Research and Development department has, over the years, developed a series of solutions featuring different shapes and sizes. This wide range of solutions allows you to install a Tecma toilet wherever there are space, style and weight constraints. Tecma toilets can be requested with integrated or separate bidet with the same geometry. The ...
Design and Flexi Line | instructions for installation and use | ENG Cleaning Ceramic is particularly suitable for toilets, as it guarantees hygiene and it is resistant against any cleaning product. Do not use acetone‐ or trichlorethylene‐based products, or any product that may irreversibly damage the rubber components of the pump/macerator/check valves. We recommend using Thetford products, as they are specifically tested for this type of systems. Do not use aggressive products or abrasive sponges on carbon or coloured products (other than white or pergamon). We recommend applying a small amount of product to the rear of the toilet first to check its suitability. ...
Design and Flexi Line | instructions for installation and use | ENG 2. OPERATING THE SYSTEM All‐in‐one control panel One button Press the “FLUSH” button to start the automatic flush cycle, after which the toilet will be refilled with a small amount of water, ready for the next use. FLUSH TANK LEVEL Two buttons Press the “BEFORE USE” button before using the toilet. This will fill the toilet with a small amount of water. Press the “AFTER USE” button after using the toilet. This will start the automatic flush cycle, which will empty the toilet. ...
Design and Flexi Line | instructions for installation and use | ENG Multiframe control panel Function Press the “BEFORE USE” button before using the toilet. This will fill the toilet with a small amount of water. Press the “AFTER USE” button after using the toilet. This will start the automatic flush cycle, which will empty the toilet. AFTER USE BEFORE USE TANK LEVEL N OTE: It is also possible to adjust the amount of water used during every flushing cycle directly from the Multiframe wall switch. A specific regulator placed on its rear increases the amount of water if turned clockwise or decreases it if turned anticlockwise. The recommended water level is 1 cm above the ceramic outlet. ...
Design and Flexi Line | instructions for installation and use | ENG Touch SFT control panel Function The Touch SFT control panel can work both in Navigation mode and in Mooring mode. The Navigation mode cycle eliminates the water inside the bowl at the end of use, preventing the possible leakage of water due to the movements of the boat. The mooring mode cycle works like domestic toilets: just the activation of the "AFTER USE" button is enough to activate the cycle in its entirety. In Mooring mode there is always a quantity of water inside the bowl to create a hydraulic cap. BEFORE USE AFTER USE TANK LEVEL LOCK OUT To switch from mooring mode to navigation mode see par. 2.3.3. ...
Page 11
Design and Flexi Line | instructions for installation and use | ENG SAILING MODE: the toilet bowl remains empty at the end of the flush cycle 2. Press the “BEFORE USE” 3. Press the “AFTER USE” button after 1. The bowl using the toilet. button before using the toilet. is empty. A combined action of the solenoid valve The solenoid valve will let in and macerator pump will clean and rinse the desired amount of water the bowl. A small water trap is created for max 12 seconds. and the toilet bowl will remain empty. ...
Design and Flexi Line | instructions for installation and use | ENG Changing flushing mode The system is set on sailing mode by default. To switch from one mode to another: 1) Press and hold the BEFORE USE and AFTER USE buttons simultaneously 2) After 3 seconds, the sensor LED will flash: keep pressing. 3) After 5 seconds, the perimeter LED will flash: release the buttons. 4) The toilet will automatically do: a. If you are setting from Sailing mode to Mooring mode: water inlet. b. If you are setting from Mooring mode to Sailing mode: pump activation. 5) Repeat the procedure to change mode again. Fig.1: from Sailing to Mooring 1. Press and hold the BEFORE USE SAILING MODE and AFTER USE buttons simultaneously 2. After 3 seconds, the sensor LED ...
Page 13
Design and Flexi Line | instructions for installation and use | ENG Fig.2: from Mooring to Sailing 1. Press and hold the BEFORE USE MOORING and AFTER USE buttons MODE simultaneously 2. After 3 seconds, the sensor LED will flash. Hold down. 3. After 5 seconds, the backlight LED will flash ...
Design and Flexi Line | instructions for installation and use | ENG Tank level LED – Block function The control panel is equipped with a 3‐colour LED, which indicates the blackwater tank level. As soon as the maximum level is reached, the sensor disables the inlet of water inside the bowl. Only the macerator pump will stay active. Lockout If for any reason you intend to bypass the block function connected to the level of the black water tank, and reactivate the inlet of water, press both buttons simultaneously two times, with an interval of about 1 sec. The "LOCK OUT" LED will come on to indicate that the panel is in lockout mode (block NOT active). The button LEDs will turn off during programming. When restarted, the control unit can be used. x 2 x 2 Block Active Block NOT Active To disable the lockout function, repeat the procedure: x 2 x 2 ...
Design and Flexi Line | instructions for installation and use | ENG Disabling the toilet for cleaning operations. Temporarily disable the buttons in order to clean the Touch control panel. 1. Place your hand on the panel for 15 seconds without touch it. 2. The backlight starts blinking for 3 sec. 3. Take your hand away. 4. Clean the panel with a cloth. 5. The buttons will be automatically enabled again after 15 seconds. Disabling the toilet for a shower Nel caso in cui il pannello Touch fosse all’interno della doccia, per evitare attivazioni involontarie legate agli schizzi d’acqua, è possibile disabilitare temporaneamente i pulsanti. ...
Design and Flexi Line | instructions for installation and use | ENG Programming the backlight You can program the Touch panel to have the backlight: a. Always on b. Always off c. Activated with a proximity sensor (default) Instructions to switch from one program to another: 1. Press and release the LED at the centre (Tank level LED) 2. Press and release simultaneously the BEFORE USE and AFTER USE buttons. 3. Wait 2/3 seconds before performing other operations. This way, you will switch from one program to another simultaneously ALWAYS OFF PROXIMITY ALWAYS ON Pump manual activation In caso di necessità, è possibile effettuare un ciclo con la sola attivazione della pompa maceratrice. Press simultaneously both buttons for 3 seconds until the Lock LED flash and release. ...
Design and Flexi Line | instructions for installation and use | ENG Anti overflow function To avoid possible overflows related to excessive consecutive inlet of water with the "BEFORE USE" button, an automatic block is enabled which does not allow more than two consecutive inlets. The lock is disabled the next time the macerating pump is activated. N OTE: effectiveness is not guaranteed if the water inlet level has not been appropriately set. The "After Use" cycle will in any case introduce a quantity of water. If only pump activation is required, see function 2.3.9 Manual pump activation. Reset If it is necessary, it is possible to activate the system reset function. a. Press and hold the LED at the centre (Tank level LED) for 10 seconds. All the LEDs will flash as reset confirmation. Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY ...
Page 18
Design and Flexi Line | instructions for installation and use | ENG W ARNING: do not to exceed the tank maximum level when the “Tank Level” LED is red (lockout mode). W ARNING: If the toilet is connected to a seacock, make sure that its safety ball valve is always closed when the boat is unattended, even for a short time. W ARNING: For toilets that use fresh water systems connected (even temporarily) to the port water mains, make sure that the valve in the quay connection point is always closed when the boat is unattended, even for a short time. W ARNING: do not force the cover to close if the toilet is equipped with a soft closing system. The system is designed to close automatically and applying external force may irreversibly damage the mechanism. W ARNING: if the toilet is equipped with a bidet function, make sure not to exceed the toilet maximum level, as there is no overflow drain. Enable the macerator pump (“AFTER USE”) to empty the toilet. ...
Design and Flexi Line | instructions for installation and use | ENG 3. INSTALLATION AND SERVICE W ARNING: Read and understand the warnings listed in this document before installing, using, or servicing the system. Failure to comply with these warnings may cause injuries, damage, loss of the property, and electrocution. Any modification applied to Tecma's product may result in loss of the property, injuries, or electrocution. T ECMA SRL is not liable for damage, injuries, or death resulting from improper installation, operations, or interventions. ...
Design and Flexi Line | instructions for installation and use | ENG Only use stainless steel hardware. Always use the supplied ceramic‐protection rubber inserts. Any toilet assembly errors may result in improper movements, which may damage objects or injure persons. The toilet is designed to dispose of human waste and toilet paper. Never flush other materials types (e.g. paper towel, wet wipes, condoms, sanitary pads, dental ...
Page 21
Design and Flexi Line | instructions for installation and use | ENG described in section 3.8 "System" The Flexi 2G and Design line integrates an air admittance valve already in the discharge internal hose. In the case of non‐centralized systems (sea water) with toilet installed below the waterline, make sure the space to install the safety valve ventilation necessary authorization and discharge at a sufficiently higher proportion to it. all the FLEXI LINE 2G SHORT SHALLOW BOWL versions self‐ contain all components internally. It is no longer required to verify the space under the usual installation step. ...
Design and Flexi Line | instructions for installation and use | ENG Floor fixation The floor fixation of each head of Flexi Line and Design is using nylon brackets with side screws and floor anchors (excluding Xlight and Evolution with special mounting kit). Each toilet is provided with a template with the measures for drilling to the floor. In the specific case of the new Flexi 2G line (excluding Elegance CUT), the template reverse side is ...
Design and Flexi Line | instructions for installation and use | ENG Solenoid valve Before installing the solenoid valve, clean the pipes (brazing or welding residues, metal chips, seal material). A filter inside the solenoid valve prevents failures resulting from water impurities. We recommend cleaning the solenoid valve filter regularly. After service, screw both fitting back with the respective gaskets to the solenoid valve and tighten with a torque of 2 N/m. Do not force the solenoid valve when tightening it. Do not obstruct the pilot hole at the valve outlet. The entire piping section must be free from bottlenecks. Comply with the recommended pressure range (refer to section A.2). The solenoid can be regularly installed on the fresh water supply line, or ‐ alternatively ‐ integrated in the WC through an optional hose connection that connects directly the water ...
Design and Flexi Line | instructions for installation and use | ENG Inlet pump Install the inlet pump in a dry, ventilated place. The pump can’t be submerged or exposed to sprays. Install a fuse in the power supply circuit. The pump can be assembled horizontally as well as vertically (in this case, the pumping unit must face downwards). Install the filter before the pump. Install a vent valve to prevent siphoning phenomena, especially if the toilet is installed below the floating line W ARNING: The inlet pump must not be used as a check valve. Failure to use a vent valve may result in flooding, loss of the property, injuries, or even death. CUT‐OUT control panels Apart from the control panel "All in One" which integrates the controller in the wall interface, all panels are equipped with a control unit that can be installed either directly in the toilet or in a recess outside if more convenient. All control panels are fitted with specific electric connectors (refer to section A.2). ...
Design and Flexi Line | instructions for installation and use | ENG Cut out for Multiframe control panel: N OTE: The Multiframe control unit is supplied as standard with the Bticino Living Light series frame. For compatibility of Multiframe with commercial frames, refer to the following table: *To install the Chorus line (Gewiss) remove the fins from the Frame B (see the picture) Cut out for Touch SFT control panel: Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche ...
Design and Flexi Line | instructions for installation and use | ENG Tank sensors The sensor wiring of the control units, both in the standard one‐level version (grey / black), and in the two‐level version for Touch (red / black and white / green) have a voltage of 7V. You can connect: Sensors with clean contact (float, with pressure switch or similar) which close the contact between the two poles of the connector. Electronic sensors with the following specifications: o Power 7V. o Electrical absorption 12,75 mA +/‐1 mA when the sensor is un‐activated and 22,75 mA +/‐ 1 mA when activated. W ARNING: In any case, do not connect the sensor cable to any power source. NOTE: For the compatibility of the control units with other types of sensors or for the use ...
Design and Flexi Line | instructions for installation and use | ENG Use isopropyl alcohol (not included) to clean the side of the tank at the top ‐ approximately on the left‐right centreline where the sensor will be mounted. When thoroughly clean and dry, firmly press the sensor into place. (Note: Wires can face any direction. The direction of the sensors does not affect its operation). If available, follow the same procedure for the Mid‐Tank sensor. However, keep in mind that it should be assembled on the left‐right centreline, approximately half way up the side of the tank. The Full Tank Sensor has to attached at the highest point on the tank for the tank’s capacity, or where the installer wants the Tank Full level to be. The sensor has a removable cover over the pressure‐sensitive adhesive pad. Equipment required ‐ Electric drill with insert or screwdriver for the stainless‐steel straps. ‐ Electric drill or screwdriver to tighten the assembly screws ...
Page 28
Design and Flexi Line | instructions for installation and use | ENG Fig. 1 WARNING: The floating line must be calculated taking into consideration the various sailing trims. See fig. 2. ...
Design and Flexi Line | instructions for installation and use | ENG Centralised System ‐ Fresh Water Hydraulic system 3.8.1.1 The TECMA's toilet flushing cycles use the tank fresh water. The solenoid valve can be integrated in the toilet, directly connected to the inlet/nozzle via the supplied black rubber pipe. Alternatively, it can be mounted in the fresh water system (the one that serves sinks, showers, and other utilities). When the toilet is used, the control panel opens the solenoid valve through the control unit. The water is supplied via the autoclave, which pressurises the entire hydraulic system on board. Diagram in section A.3.5. WARNING: The recommended system operating pressure is equal to 3 bar WARNING: Keep the filters of every solenoid valve clean. ...
Design and Flexi Line | instructions for installation and use | ENG 110V/230V Electrical system 3.8.1.3 Tecma products with a 110V/230V motor have a plug, which must be connected to the power supply. Diagrams in section A.3.6.5/6. Plug Main power supply (motor and solenoid valve) ‐ Shuko CEE/ US‐Can Black/Brown transformer/control unit Black/Blue transformer/control unit Black/Grey Tank sensor/control unit Black/Red transformer/control unit W ARNING: electrical systems must be connected by qualified personnel. To choose the wire section, consider the length and power consumption. (see section 7.0). Use the connectors provided with the TECMA sanitary system. ...
Design and Flexi Line | instructions for installation and use | ENG Electrical system 3.8.2.2 Diagram in section A.3.3/4. Every control unit is wired by connecting Black/brown toilet motor Black/Blue Inlet pump Black/Grey Tank sensor Black/Red Power supply (with fuse on the red wire) The « BEFORE USE » button starts the pump, whilst the « AFTER USE » pump starts a program, which activates the pump before starting the toilet motor. ...
Page 32
Design and Flexi Line | instructions for installation and use | ENG Mixer body 42mm OD 55mm lenght Flange OD 60mm / ID Mounting bracket Mixed water to toilet Hot or cold‐water supply Standard 3/8” connection (threaded Hardware + Handle female) gaskets The nozzle The nozzle is mounted directly on the toilet ceramic body. Plug the hoses and the installation is done! Bidet mixed water supply (from mixer) 3/8” female threaded connection ...
Page 33
Design and Flexi Line | instructions for installation and use | ENG Option 1: Mixer and handle integrated to the ceramic toilet * Water inlet nozzle Hot or cold‐water supply 3/8” connection Option 2: Mixer and handle wall mounted (Privilege / Evolution) * Water inlet nozzle 600mm Hot or cold‐water supply 3/8” connections 3/8” threaded connection *refer to each model PIS to check if the bidet function is available with integrated or wall mounted mixer. Refer to each model technical drawing to check the exact position of the handle (always on the right‐hand side) ...
Design and Flexi Line | instructions for installation and use | ENG Mixer OD 42 mm Length 55 mm (chromed part) Any other commercial handle/mixer can alternatively be used to mix the water The customer is free to select a wall mounted mixer from the same collection of the bathroom and use it to control the bidet integrated in the toilet. In this case do not use the mixer provided and install the mixer/handle that you prefer. Make sure to do the plumbing right. In case of any doubt contact Tecma technicians. 4. TROUBLESHOOTING Refer to the Troubleshooting available on the website: ...
Design and Flexi Line | instructions for installation and use | ENG Comply with the environmental protection standards in force when choosing and using these products. We recommend cleaning the tanks and pipes with Thetford Tank Freshener. Is it possible to use acid or aggressive products? Plastic components of the TECMA toilet have been tested with several marketed cleaning products. Avoid using products such as vinegar, acetone, trichlorethylene. Avoid using solvents so as not to affect the rubber components. Moreover, avoid using gel and foams in order not to obstruct the vent valves. Do not dispose of harmful substances into the sea. What kind of tube must be used? The TECMA macerator pump uses any type of pipes (armovin, PVC, safeodor) to discharge. We always recommend using a DN 40 pipe. Which spare parts should I keep on board? Besides a control panel, a motor, and the solenoid valve, we recommend keeping a sleeve kit to completely regenerate the toilet. Do I have to install a ventilated siphon behind the toilet bulkhead? In case of non‐centralized systems (sea water) with toilet installed below the waterline it is mandatory to install a ventilated siphon sufficiently higher than that. The exact height must be determined according to the maximum boat heeling angle. For any system with long discharge pipes and risk of siphoning, it is always recommended to install ...
Design and Flexi Line | APPENDIX APPENDIX SPARE PARTS LIST / LISTA DEI RICAMBI Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 142 ...
Page 37
Design and Flexi Line | APPENDIX To find the closest service center please visit the website: www.thetfordmarine.com *Per scoprire il service centre più vicino a voi visitate il sito: Para encontrar el centro de servicio más cercano, visite el sitio web: * Pour trouver le centre de service plus près, s'il vous plaît visitez le site de Web : www.thetfordmarine.com To order parts in North America, please refer to the list of spare parts and codes available on "www.thetfordmarine.com" in the session" United States". *Per ordinare ricambi in Nord America, si prega di fare riferimento alla lista di ricambi e codici disponibili sul listi "www.thetfordmarine.com", nella sessione "United States". *Para solicitar piezas en América del Norte, por favor consulte la lista de piezas de repuesto y los códigos disponibles en istas "www.thetfordmarine.com" en sesión" United States ". *Pour commander des pièces en Amérique du Nord, se il vous plaît se référer à la liste des pièces de rechange et les codes disponibles sur istes "www.thetfordmarine.com" en session" United States". Recommended spares on board: 1 spare motor of the right voltage ‐ motore del voltaggio adeguato – Drawing n. 1 ...
Page 38
Design and Flexi Line | APPENDIX Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 144 ...
Page 39
Design and Flexi Line | APPENDIX ‐ Seat and cover table / ‐ Elenco dei coprisedile L is the length of the cover / L è la lunghezza del coperchio Profile view of thermosetting: Profile view of polyester: Vista di profilo del termoindurente Vista di profilo del poliestere Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 145 ...
Page 40
Design and Flexi Line | APPENDIX Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 146 ...
Design and Flexi Line | APPENDIX TECHNICAL DATA / DATI TECNICI MAC 11 110- 125V AC 220- 240V AC 12V DC 24V DC OUT LET PUMP 60Hz 50Hz or 60 Hz Fuse r ecom m ended 71. 3 gpm Max 270L/ m i n Pum p per f or m ance Max ver t i cal head 11m t 36.
Page 42
Design and Flexi Line | APPENDIX 220- 240V AC 110- 125V I NLET SOLENOI D 12V DC 24V DC 50Hz or 60 AC 60Hz Cent r al i zed syst em Power consum pt i on 9. 5 W 10 W Wor ki ng pr essur e r ecom m ended 3 bar...
Design and Flexi Line | APPENDIX SYSTEM DIAGRAMS / DIAGRAMMI DEGLI IMPIANTI A.3.1. Single System / Impianto Singolo Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) ...
Design and Flexi Line | APPENDIX A.3.2. Multiple Single System / Impianto Singolo Multiplo Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY ...
Design and Flexi Line | APPENDIX A.3.3. Single System Wiring / Cablaggio Impianto Singolo A.3.4. Multiple Single System Wiring / Cablaggio Impianto Singolo Multiplo In case of installations other than those indicated in the diagrams, please contact Tecma for compatibility check. Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 151 ...
Page 46
Design and Flexi Line | APPENDIX A.3.5. Centralized Fresh Water System / Impianto Centralizzato Acqua Dolce Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY ...
Page 47
Design and Flexi Line | APPENDIX A.3.6. Centralized Fresh Water Wiring / Cablaggio Centralizzato Acqua Dolce 12 V/24 V with All In One Switch In case of installations other than those indicated in the diagrams, please contact Tecma for compatibility check. Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 153 ...
Page 48
Design and Flexi Line | APPENDIX 12 V/24 V with Multiframe Switch In case of installations other than those indicated in the diagrams, please contact Tecma for compatibility check. Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 154 ...
Page 49
Design and Flexi Line | APPENDIX 12 V/24 V with Touch SFT Wall Switch In case of installations other than those indicated in the diagrams, please contact Tecma for compatibility check. Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 155 ...
Page 50
Design and Flexi Line | APPENDIX 110 V/230 V with All In One Switch In case of installations other than those indicated in the diagrams, please contact Tecma for compatibility check. Tecma S.r.l. Via Flaminia | Loc. Castello delle Formiche T +39 0744 709071 05030 Otricoli (TR) info@tecma.eu ITALY www.thetfordmarine.com 156 ...
Page 51
Design and Flexi Line | APPENDIX A.3.7. Sensors Connection Guide / Guida alla Connessione dei Sensori Al l I n One SFT 1P- 2P / Mul t i f r am e SFT 2P: One l evel FIELD EFFECT BROWN GREY SENSOR FULL BLACK ...
Need help?
Do you have a question about the TECMA DESIGN LINE and is the answer not in the manual?