Advertisement

Quick Links

G 32 Т Terminal
USER MANUAL
G 32 T
TERMINAL
(rev. 3.0)
©2022, Euro Games Technology Ltd.
www.egt.com
Page 1
www.egt.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G 32 T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EGT G 32 T

  • Page 1 G 32 Т Terminal USER MANUAL G 32 T TERMINAL (rev. 3.0) ©2022, Euro Games Technology Ltd. www.egt.com Page 1 www.egt.com...
  • Page 2: Table Of Contents

    Bill Validator (Option) ..........................24 Ticket Printer (option) ..........................24 Keyboard Panel ............................25 Meter Module ............................26 Signal Lights Controller ..........................26 Decorative Lighting ..........................26 iButtons Reader and Socket ........................27 Audio System ............................27 Page 2 www.egt.com...
  • Page 3 Error Messages ............................28 Applications ..............................29 Bill Validator Models and Technical Parameters ..................29 Ticket Printer Models and Technical Parameters ..................39 Modular Diagram of Components ......................42 Connectors of the Backplane Board ......................50 Contacts ..............................54 Page 3 www.egt.com...
  • Page 4: Revision History

    • The models of bill validators and printers, as well as their technical parameters, are listed in the Applications section. The manufacturer shall reserve its right to make changes and amendments to the item and documentation without prior notification of the customer. Page 4 www.egt.com...
  • Page 5: Signs Used

    G 32 Т Terminal Signs Used Note: Gives important or additional information. Warning! Warns about specific conditions or situations which require due attention. Page 5 www.egt.com...
  • Page 6: Introduction

    Introduction General Description • The G 32 T terminals are designed for use in casinos and gambling halls. • The terminal is powered by the Exciter III/ Exciter IV gaming platform, specially created by Euro Games Technology (EGT) which complies with the newest requirements of the gaming industry.
  • Page 7: Dimensions

    100 - 240 V~ (from -10% to +10%), 50 ÷ 60Hz Used in indoors Transportation • Only move the terminal when the power is off. • The transport terminal must be in a vertical and a stable position, protected from movement and shocks while driving. Page 7 www.egt.com...
  • Page 8: Safety And Precaution Measures

    The terminal is not designed to be used by persons (including children) with reduced physical, sensory, or mental abilities, or by persons with a lack of experience and knowledge unless they have a supervisor or instructor responsible for their safety. • Children should be supervised to not play with the terminal. Page 8 www.egt.com...
  • Page 9: Installation

    Turn the main power switch on and wait for the appearance of a picture on the screen; • Teach the software in the iButton Reader to recognize EGT electronic keys (see EGT Electronic Keys_ iButton Reader Teaching_Service_Manual_EN_0x.pdf or contact the EGT Service);...
  • Page 10: Service

    After forming/adding a credit the player credit cannot be bigger than the credit limit, set in the terminal service functions. Forming a Credit via the Attendant Key • procedure This is for the service staff (attendant) in the casino, who uses a special key to insert credit. Page 10 www.egt.com...
  • Page 11 There must be a bill validator in the terminal, and it has to be enabled and set in the terminal initial setup. 1. Insert the banknote, or ticket, or voucher into the bill validator entrance: 2. The CREDIT field updates with the inserted banknote value. Page 11 www.egt.com...
  • Page 12: Cashing Out The Player's Credit

    Cashing Out by Attendant - Handpay 1. Press the CASH OUT button. • Handpay Call Attendant splash appears on the center of the screen: 2. Press the SERVICE button, placed on the right, over the ticket printer exit, to call the attendant. Page 12 www.egt.com...
  • Page 13: Terminal Reservation And Release

    • The game picture with the RESERVE sign appears on the screen. • The terminal is locked for playing or the credit changing until you unlock it. 4. Tap the Unlock button to release (UNLOCK) the terminal. Page 13 www.egt.com...
  • Page 14: Signal Lights

    • • Display network condition immediately after hiding network threats. condition threats. Note: For some markets the colors of the lamp and its conditions may differ from those described. Page 14 www.egt.com...
  • Page 15: Doors Opening And Closing

    1.a. Put the corresponding passkey 1 in the right lock and turn it clockwise. The lock is shown in the picture below and is located below the keyboard. 1.b. Put the corresponding passkey 2 in the left lock and turn it clockwise. 2. The main door is released and automatically opens upwards. Page 15 www.egt.com...
  • Page 16 G 32 Т Terminal Main Door Closing 1. Grab the open main door and pull it down. 2. Press the door firmly down until it closes completely Page 16 www.egt.com...
  • Page 17 1. Unlock the bill validator door with the corresponding passkey. The lock is located below the keyboard, in the middle. 2. Open the door by gently holding it until full opening. Bill Validator Door Closing 1. Lift the bill validator door. 2. Press forward and lock the door. Page 17 www.egt.com...
  • Page 18 3. Unscrew the wing nut completely and set it aside. The wing nut is located inside the terminal when viewed from the top right to the entrance of the banknote validator (see image). 4. The Safety Sheet is released and you can pull it toward you to open. Page 18 www.egt.com...
  • Page 19: Component Maintenance

    Clean only when the power is Exciter III/ and may hinder its normal switched off! For prevention, you may Exciter IV operation. contact the nearest authorized EGT Connectors service center. Board Monitors/ Upon normal operation, a Minimum once a week,...
  • Page 20 In this case, check the meter circuit. If the defect is in the meter itself, it shall be replaced by a new one of the same types. Page 20 www.egt.com...
  • Page 21: Hardware Components

    G 32 Т Terminal Hardware Components General Description of the Components Front View of the Terminal with All Doors Closed Terminal Back ’ Page 21 www.egt.com...
  • Page 22 The access is restricted by a locking system with a secret lock, and the doors switch as well which is controlled even when the power of the terminal is turned off. • Each access is registered in the Security Accounting menu in service functions. Page 22 www.egt.com...
  • Page 23: Power Distributor Units (Pdu) And Power Supply Units (Psu)

    The specialized gaming platform is the managing computer (platform) in the terminal. • The G 32 T terminal can work with one of the two developed by the Euro Games Technology gaming platforms Exciter III or Exciter IV. Exciter III Specialized Gaming Platform...
  • Page 24: Monitor

    Bill Validator Models and Technical Parameters in the Applications. Ticket Printer (option) Purpose of Use • The printer prints vouchers and tickets when credits are cashed out from the terminal. Page 24 www.egt.com...
  • Page 25: Keyboard Panel

    The button LED test is performed by the test mask, which is set from the terminal service menu. Keyboard Panel Used for navigation during the game and service functions. Technical parameters USB Keyboard Controller Parameter Value Number of buttons controlled up to18 Number of LEDs controlled up to 18 Page 25 www.egt.com...
  • Page 26: Meter Module

    Decorative Lighting Type Includes the following modules: • The white lighting of the EGT logo, at the bill validator entrance and ticket printer exit. • The red lighting of the EGT logo on the back of the terminal. • The RGB lighting is situated around: the monitor, the main door, and the footrest, on the two sides of the terminal and the back.
  • Page 27: Ibuttons Reader And Socket

    The switches detect openings and closings of all doors. Terminal Identification Type Cabinet ID Purpose of Use It uniquely determines the type of terminal - number of monitors, type of monitors, resolution of monitors, orientation of monitors - horizontal or vertical. Page 27 www.egt.com...
  • Page 28: Terminal Troubleshooting

    The errors that occur are displayed on the terminal screen in a form of a message. The error is cleared when its cause is solved. • Connect to the EGT service desk and report the information in the error message if you cannot solve the problem. Page 28...
  • Page 29: Applications

    Bill/Voucher Validation and Stacking Time ~ 3s Cassette Capacity Up to 500 bills/vouchers CashCode MFL Electrical Parameters Value Power Supply Voltage 12V DC ± 10% Standby 0.2 A Current consumption Operating mode max 2 A Standby 2.4 W Page 29 www.egt.com...
  • Page 30 12V DC - 5% to 24V DC +10% Standby 24V DC - 0.2 A, 12V DC - 0.2 A Current consumption Operating mode 24V DC - 1.3 A, 12V DC - 2.3 A Maximum 24V DC - 3.2 A, 12V DC - 3.0 A Page 30 www.egt.com...
  • Page 31 Cassette Capacity Up to 500 bills/vouchers Validation Rate ≥96% Length of Bills/Vouchers Accepted 115 ÷ 170 mm Width of Bills/Vouchers Accepted 62 ÷ 83 mm Bill/Voucher Validation and Stacking Time max 5s Cassette Capacity Up to 500 bills/vouchers Page 31 www.egt.com...
  • Page 32 G 32 Т Terminal Components Bill Validator Components Model MEI SCN8347(E) Cashcode MFL JCM UBA-10-SS Page 32 www.egt.com...
  • Page 33 Plate down (Activate the lever to confirm the DIP Switch Block (JCM Custom Private Line) denomination value through Cash Box Windows “R”). Acceptor Unit Release Pushbutton Frame Housing (LD Version). Status LED (Four (4) colors: Red/Yellow/Green & Blue) Page 33 www.egt.com...
  • Page 34 3. Unlock the cassette cover by inserting appropriate keys in the locks and turning clockwise, as shown in the - 2 - picture above. Open the cover. 4. Take the bills, as shown in the picture – 3 - above. 5. Lock the cassette and put it back into the housing. Page 34 www.egt.com...
  • Page 35 4. Put back the cassette into the housing. Removing Jammed Bills Removing Jammed Bills from CashCode MFL Depending on the situation encountered jammed bills must be removed as shown in the picture above. Removing Bills from JCM UBA-10-SS Page 35 www.egt.com...
  • Page 36 The function of the group of SW1 DIP switches is the following: Switch SW 1.1 Denomination 1 enabled Denomination 1 disabled SW 1.2 Denomination 2 enabled Denomination 2 disabled SW 1.3 Denomination 3 enabled Denomination 3 disabled Page 36 www.egt.com...
  • Page 37 Defining settings, operating mode, and enabled denominations is performed by setting switches. Switch Accept of barcode vouchers disabled Accept of barcode vouchers enabled Denomination 1 disabled Denomination 1 enabled Denomination 2 disabled Denomination 2 enabled Denomination 3 disabled Denomination 3 enabled Denomination 4 disabled Denomination 4 enabled Page 37 www.egt.com...
  • Page 38 Set all SW1 switches in the OFF position as shown in the picture above. JCM iVizion-SS Serial Communication DIP switches settings: Set the two switches in the shown position on the picture above (opposite the Mark) to use the RS232 communication interface. Page 38 www.egt.com...
  • Page 39: Ticket Printer Models And Technical Parameters

    203 dpi x 203 dpi Print Width 62 mm Tickets capacity 300 vouchers Ticket Parameters Value Ticket Width 66 mm Ticket Length (between perforations) 156 ± 1 mm Ticket Thickness 4,5 mil, 1 color / 2 colors Page 39 www.egt.com...
  • Page 40 1. Load tickets into the ticket supply tray, so that it lays flat as shown in the picture 1 above. 2. Insert the leading ticket into the ticket in slot as shown in the picture 2 above. Page 40 www.egt.com...
  • Page 41 1. Load tickets into the ticket supply tray, making sure that the black dot is positioned as shown in the picture above. 2. Insert the leading ticket into the printer mechanism’s insertion guide area. The ticket should be fed about a ½" into the mechanism; at this time, the terminal automatically completes the feeding process. Page 41 www.egt.com...
  • Page 42: Modular Diagram Of Components

    G 32 Т Terminal Modular Diagram of Components Power Page 42 www.egt.com...
  • Page 43 G 32 Т Terminal EXCITER III Page 43 www.egt.com...
  • Page 44 G 32 Т Terminal EXCITER IV Page 44 www.egt.com...
  • Page 45 G 32 Т Terminal RGB lights Page 45 www.egt.com...
  • Page 46 G 32 Т Terminal 32" EGT Monitor Page 46 www.egt.com...
  • Page 47 G 32 Т Terminal 4-button Keyboard Page 47 www.egt.com...
  • Page 48 G 32 Т Terminal 11-button Keyboard Page 48 www.egt.com...
  • Page 49 G 32 Т Terminal Optional Peripherals Page 49 www.egt.com...
  • Page 50: Connectors Of The Backplane Board

    DIN8 DIN9 DIN10 DIN11 DOUT0 DOUT1 DOUT2 DOUT3 DOUT4 DOUT5 DOUT6 DOUT7 INTRUSION0 INTRUSION1 INTRUSION2 INTRUSION3 INTRUSION4 INTRUSION5 INTRUSION6 POWER INPUT MOLEX 4x2pin mini-fit Straight PIN No Signal Name PIN No Signal Name +12V +12V +12V +24V Page 50 www.egt.com...
  • Page 51 Serial Bill Acceptor MOLEX 2x2pin Mini-fit Straight PIN No Signal Name PIN No Signal Name R_RXD4 R_TXD4 +12V / 3A 12V OUT MOLEX 2x2pin Mini-fit Straight PIN No Signal Name/Current PIN No Signal Name/Current N.C. N.C. +12V / 1.5A Page 51 www.egt.com...
  • Page 52 Signal Name PIN No Signal Name CCT-DAT CCT-DAT (COM7) +12V / 3A +12V / 3A +12V / 3A +12V / 3A EXT_DIN0 EXT_DIN1 EXT_DIN2 EXT_DIN3 Cabinet FANS CviLux CI3103P1V00 PIN No Signal Name +12V / 1.5A N.C. Page 52 www.egt.com...
  • Page 53 +12V / 1.5A UPS POWER V1.6 MOLEX 2x2pin Mini-fit Straight PIN No Signal Name/Current PIN No Signal Name/Current BU+12V BU+12V UPS POWER V2.2 MOLEX 3x2pin Mini-fit Straight PIN No Signal Name/Current PIN No Signal Name/Current BU+12V BU+12V BU+12V Page 53 www.egt.com...
  • Page 54: Contacts

    Address 6 Panorama Sofia Str., Sofia Park RichHill Business Center, Block A 1756 Sofia, BULGARIA EGT Technical Support - Head Office Phone: +359 2 890 24 68 Fax: +359 2 890 24 88 Mobile: +359 896 71 02 72 e-mail: service@egt-bg.com;...

Table of Contents