MOTOR PROGRAMMING INSTRUCTIONS
5V Zero & Li-ion Wire-free Motors
SOFT STOP
ELECTRONIC
USB CHARGE
SOLAR OPTION
USE THIS DOCUMENT WITH THE FOLLOWING MOTORS:
PART NUMBER
MT01-1325-069028-CT
MT01-1325-069029-CT
MT01-1328-069008-CT
MT01-1325-069030-CT
MT01-1325-069031-CT
MT01-1325-069032
MT01-1325-069033
MT01-1328-069009
MT01-1325-069034-CT
MT01-1325-069035-CT
MT01-1328-069010-CT
MT01-1325-069037-CT
MT01-1335-069003
MT01-1335-069002
MT01-1345-069004
MT01-1345-069003
AUTOMATE V4_PRGM_JUN_2024
SELECTABLE
LIMIT
SPEED
LEVEL CONTROL
DESCRIPTION
5V ZERO LI-ION 0.7NM CT20 Q MOTOR [Ø25/5V/20RPM](SKY)
5V ZERO LI-ION 1.1NM CT20 Q MOTOR [Ø25/5V/28RPM](SKY)
5V ZERO LI-ION 2.0NM CT15 Q MOTOR [Ø28/5V/28RPM](SKY)
5V ZERO LI-ION 1.1NM CT20 Q MOTOR [Ø25/5V/28RPM](LVO)
5V ZERO LI-ION 1.1NM CT20 Q MOTOR [Ø25/5V/28RPM](UNV)
5V ZERO LI-ION 0.7NM Q MOTOR [Ø25/5V/20RPM](S45)
5V ZERO LI-ION 1.1NM Q MOTOR [Ø25/5V/20RPM](S45)
5V ZERO LI-ION 2.0NM Q MOTOR [Ø28/5V/20RPM](S45)
5V ZERO LI-ION 0.7NM CT20 Q MOTOR [Ø25/5V/20RPM](R8)
5V ZERO LI-ION 1.1NM CT20 Q MOTOR [Ø25/5V/28RPM](R8)
5V ZERO LI-ION 2.0NM CT15 Q MOTOR [Ø28/5V/28RPM](R8)
5V ZERO LI-ION 0.7NM CT20 Q MOTOR [Ø25/5V/28RPM](SKY)
AUTOMATE | DC 6NM MOTOR [Ø35/5V/20RPM]
AUTOMATE | LI-ION 6NM MOTOR [Ø35/5V/20RPM]
AUTOMATE | DC 6NM MOTOR [Ø45/5V/20RPM]
AUTOMATE | LI-ION 6NM MOTOR [Ø45/5V/20RPM]
Fav Position
Live Feedback
Energy e cient
433 MHZ
FAVORITE
BI-DIRECTIONAL
POSITION
BATTERY
POWERED
BATTERY CHECK
A division of Rollease Acmeda

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MT01-1325-069028-CT and is the answer not in the manual?

Questions and answers

Summary of Contents for Automate MT01-1325-069028-CT

  • Page 1 MT01-1328-069010-CT 5V ZERO LI-ION 2.0NM CT15 Q MOTOR [Ø28/5V/28RPM](R8) MT01-1325-069037-CT 5V ZERO LI-ION 0.7NM CT20 Q MOTOR [Ø25/5V/28RPM](SKY) MT01-1335-069003 AUTOMATE | DC 6NM MOTOR [Ø35/5V/20RPM] MT01-1335-069002 AUTOMATE | LI-ION 6NM MOTOR [Ø35/5V/20RPM] MT01-1345-069004 AUTOMATE | DC 6NM MOTOR [Ø45/5V/20RPM] MT01-1345-069003 AUTOMATE | LI-ION 6NM MOTOR [Ø45/5V/20RPM]...
  • Page 2 Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately. 2 | Automate Programming Instructions | 5V Li-ion Tubular Motors ® A division of Rollease Acmeda...
  • Page 3: Table Of Contents

    9.2 Toggle motor to Roller Mode ADJUSTING SPEED 10.1 Increase motor speed 10.2 Decrease motor speed SOFT STOP CONFIGURATION 11.1 Turn Soft Stop OFF 11.2 Turn Soft Stop ON Programming Instructions | 5V Li-ion Tubular Motors | 3 Automate A division of Rollease Acmeda ®...
  • Page 4: Assembly

    ASSEMBLY 4 | Automate Programming Instructions | 5V Li-ion Tubular Motors ® A division of Rollease Acmeda...
  • Page 5: Retrofit Installation

    RETROFIT INSTALLATION CHARGING Automate Programming Instructions | 5V Li-ion Tubular Motors | 5 A division of Rollease Acmeda ®...
  • Page 6: P1 Button Functions

    Activate Pairing Mode Approx. Sleep Mode P1 button on motor head. Approx. Approx. Reverse Direction Approx. Approx. Approx. Reset To Factory Settings Approx. Approx. Approx. Approx. 6 | Automate Programming Instructions | 5V Li-ion Tubular Motors ® A division of Rollease Acmeda...
  • Page 7: Initial Set-Up

    Damage to shade may occur when operating motor prior to IMPORTANT setting limits. Attention should be given. Reversing motor direction using this method is only possible during initial set-up Programming Instructions | 5V Li-ion Tubular Motors | 7 Automate A division of Rollease Acmeda ®...
  • Page 8: Set Limits

    To save lower limit, hold DOWN and STOP. on controller. Motor Response Approx. IMPORTANT After setting limits, motor will automatically exit from initial set-up mode. 8 | Automate Programming Instructions | 5V Li-ion Tubular Motors ® A division of Rollease Acmeda...
  • Page 9: Adjusting Limits

    The bottom limit should be set ~ 1.38 in. (35mm) below the Ultra-Lock to disengage the auto lock mechanism when the shade is raised. Programming Instructions | 5V Li-ion Tubular Motors | 9 Automate A division of Rollease Acmeda ®...
  • Page 10: Controllers And Channels

    Press P2 on controller B to remove controller A. controller A. Motor Response Motor Response Motor Response IMPORTANT Consult user manual for your controller or sensor 10 | Automate Programming Instructions | 5V Li-ion Tubular Motors ® A division of Rollease Acmeda...
  • Page 11: Favorite Positioning

    Send shade to favorite position Approx. Delete favorite position Press P2 on controller. Press STOP on controller. Press STOP on controller. Motor Response Motor Response Motor Response Programming Instructions | 5V Li-ion Tubular Motors | 11 Automate A division of Rollease Acmeda ®...
  • Page 12: Tilt & Roller Mode

    If motor is in Tilt Mode, use following steps to change to Roller Mode. Hold UP & DOWN on controller. Press STOP on controller. Motor Response Motor Response Approx. 12 | Automate Programming Instructions | 5V Li-ion Tubular Motors ® A division of Rollease Acmeda...
  • Page 13: Adjusting Speed

    Press UP Motor Response Motor Response Motor Response 10.2 Decrease Motor Speed Press P2 Press DOWN Press DOWN Motor Response Motor Response Motor Response Programming Instructions | 5V Li-ion Tubular Motors | 13 Automate A division of Rollease Acmeda ®...
  • Page 14: Soft Stop Configuration

    Turn Soft Stop ON Motor must be in fastest speed to turn Soft Stop ON. Press P2 Press UP Press UP Motor Response Motor Response Motor Response 14 | Automate Programming Instructions | 5V Li-ion Tubular Motors ® A division of Rollease Acmeda...
  • Page 15: Battery Check Function

    Hold DOWN to toggle off Hold DOWN to toggle on Motor Response Motor Response Red LED flashes x3 Red LED flashes x3 Approx. Approx. Programming Instructions | 5V Li-ion Tubular Motors | 15 Automate A division of Rollease Acmeda ®...
  • Page 16: Sleep Mode

    Broadmeadows VIC 3047, AUS T +1 800 552 5100 | F +1 203 964 0513 T +61 3 9355 0100 | F +61 3 9355 0110 16 | Automate Programming Instructions | 5V Li-ion Tubular Motors ® A division of Rollease Acmeda...