Advertisement

Owner's Instruction and Operation Manual
Model Number:
EWVFS32(NV)(PV)
Report Number: 21-721
Certified for installations in the USA
Approved for installation in mobile homes
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Please read this manual BEFORE installing and
operating this unit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Save These Instructions In A Safe Place For Future Reference.
FIRE OR EXPLOSION HAZARD
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
For more information, visit www.cuiheat.com
WARNING:
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
PH. 800-845-5301
854090B-2905N
www.P65warnings.ca.gov

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EWVFS32NV and is the answer not in the manual?

Questions and answers

Summary of Contents for Everwarm EWVFS32NV

  • Page 1 Owner’s Instruction and Operation Manual Model Number: EWVFS32(NV)(PV) Report Number: 21-721 Certified for installations in the USA Approved for installation in mobile homes * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary. 854090B-2905N Save These Instructions In A Safe Place For Future Reference. WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 IMPORTANT INFORMATION CODES WARNING: FIRE,EXPLOSION, Adhere to all local codes or, in their absence, the latest ASPHYXIATION HAZARD edition of NFPA54. • IMPROPER ADJUSTMENT, ALTERATION, SERVICE, MAINTENANCE, OR INSTALLATION OF THIS HEATER OR ITS CONTROLS CAN CAUSE DEATH OR SERIOUS INJURY.
  • Page 3: Installation Checklist

    Your gas stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified. org/public/find-an-nfi-pro/ For customer service, please contact your EverWarm dealer or visit www.cuiheat.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4: Massachusetts Residents Only

    MASSACHUSETTS RESIDENTS ONLY REQUIREMENTS FOR THE COMMONWEALTH OF installed on the next adjacent floor level. In the event that the requirements of this subdivision can not be met at the time MASSACHUSETTS of completion of installation, the owner shall have a period This product must be installed by a licensed plumber of thirty (30) days to comply with the above requirements;...
  • Page 5: Safety Information

    MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special When the manufacturer of Product Approved side wall venting systems”, the following requirements shall be horizontally vented gas equipment provides a venting system satisfied by the manufacturer: design or venting system components with the equipment,...
  • Page 6 SAFETY INFORMATION 15. This is an unvented gas-fired heater. It uses air (oxygen) two to three hours with the burner at the highest setting. from the room in which it is installed. Provisions for Provide maximum ventilation by opening windows or adequate combustion and ventilation air must be doors to allow odors to dissipate.
  • Page 7: Product Features

    PRODUCT FEATURES IGNITION CONTROLS On/Off Switch Piezo ignitor allows ignition of the pilot without the use of matches. Millivolt control has four (4) positions: All gas to the burner is shut off at the valve. Valve position to light/maintain a standing pilot.
  • Page 8: Getting Started

    GETTING STARTED • Sediment trap (recommended) CAUTION: • Pipe wrench GLOVES RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS TO PREVENT SKIN IRRITATION • Pipe sealant approved for use with propane/LPG (resistant FROM LOOSE FIBERS. LOGS ARE FRAGILE — HANDLE to sulfur compounds) WITH CARE.
  • Page 9: Clearances And Height Requirements

    CLEARANCES AND HEIGHT REQUIREMENTS WARNING: Min Ceiling From Floor 72” THE DIMENSIONS SHOWN ARE MINIMUM CLEARANCES Mantel Depth (maximum protrusion) 12” TO MAINTAIN IN INSTALLING THIS HEATER. LEFT AND Top of Unit to Mantel (minimum height) 18” RIGHT CLEARANCES ARE DETERMINED WHEN FACING THE Minimum to a Side Wall 2”...
  • Page 10: Installation

    INSTALLATION CAUTION! THE APPLIANCE IS VERY HEAVY. THE ASSISTANCE FROM A SECOND PERSON IS STRONGLY SUGGESTED. PLEASE USE PROPER LIFTING TECHNIQUE WHEN POSITIONING THE APPLIANCE FOR ASSEMBLY AND INSTALLATION. 1. Remove the two (2) straps, and open the wrapping. Slide the bag to the bottom of the unit. Wrapping Straps Leg is removed for...
  • Page 11 INSTALLATION 6. Reverse steps 2-4 to reinstall the screen and front of the stove. Screen BACK CAUTION: THE APPLIANCE IS VERY HEAVY. THE ASSISTANCE FROM A SECOND PERSON IS STRONGLY SUGGESTED. PLEASE USE PROPER LIFTING TECHNIQUE WHEN POSITIONING THE APPLIANCE FOR ASSEMBLY AND INSTALLATION. Side of unit is removed MODEL #: B150 - ROOM BLOWER (sold separately)
  • Page 12: Connect Gas Line

    CONNECT GAS LINE IMPORTANT: Hold heater valve firmly with a wrench to WARNING: prevent movement when connecting to inlet pipe. Always USE NEW BLACK IRON OR STEEL PIPE. INTERNALLY use an external regulator for all propane/LPG heaters and TINNED COPPER OR COPPER TUBING CAN BE USED high pressure one to two-pound systems only, to reduce the PER NATIONAL FUEL CODE, SECTION 2.6.3, PROVIDING supply tank pressure to a maximum of 13”...
  • Page 13 ELECTRICAL WIRING (MILLIVOLT) ODS Pilot On/Off Switch ODS Pilot Wall Switch On/Off Millivolt Valve Switch Spade Terminal On/Off Switch CONNECTION 1 = TP, TH 2 = TP 3 = TH Connect Meter Leads Switch or Thermostat Meter Reading Should Check Test To Test to Terminals Contacts...
  • Page 14: Log Placement

    LOG PLACEMENT 2. Install left bottom log (#2) on left log support bracket in WARNING: front of back log. POSITIONING OF THE LOGS IS CRITICAL TO THE SAFE AND CLEAN OPERATION OF THIS HEATER. SOOTING AND Right Top Right To Log #5 Log #5 Right Top...
  • Page 15: Flame Appearance

    Right Log O FF O FF Support Bracket LOG PLACEMENT GLOWING EMBERS (ROCK WOOL) PLACEMENT 4. Install top left log (#4) on top of left bottom log. Provided with your log set is a package of glowing embers (rock wool). Break up the glowing embers into small dime Right Top P IL sized pieces or for a finer finish use a metal wire brush.
  • Page 16: Operation

    Thermocouple for LP Thermocouple LOG PLACEMENT for LP MILLIVOLT CONTROL CORRECT Thermocouple WRONG for Natural Thermocouple for Natural Thermocouple for LP Thermocouple for LP P IL CORRECT Thermocouple WRONG for Natural BURNER FLAME In normal operation at full rate after 15 minutes, the following flame appearances should be observed: The left and right rear flames should be yellow and extend 1”- 2”...
  • Page 17 Optional Fan Ignitor, Control Knobs and Optional Controls OPERATION D. Do not use this appliance if any part of it has been 11. If the heater will not operate, follow the instructions “To under water. Immediately call a qualified service Turn Off Gas To Appliance”...
  • Page 18: Cleaning And Servicing

    Other information that may be needed would be the part number and part description of the item(s) in question. Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact your EverWarm dealer or visit www.cuiheat.com Model Information Model Number Dealer’s Name...
  • Page 19: Troubleshooting

    TROUBLESHOOTING WARNING: TURN THE APPLIANCE “OFF” AND ALLOW TO COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR THE HEATER. PROBLEM POSSIBLE CAUSE REMEDY Ignitor electrode positioned Replace ignitor. wrong. Ignitor electrode is broken. Replace ignitor. When the ignitor Ignitor electrode not connected to Reconnect ignitor cable.
  • Page 20 TROUBLESHOOTING WARNING: IF THE GAS QUALITY IS BAD, YOUR PILOT MAY NOT STAY LIT, THE BURNERS MAY PRODUCE SOOT AND THE HEATER MAY BACKFIRE WHEN LIT. IF THE GAS QUALITY OR PRESSURE IS LOW, CONTACT YOUR LOCAL GAS SUPPLIER IMMEDIATELY. PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 21: Replacement Parts

    REPLACEMENT PARTS Part # Description Part # Description 40861 VF Grate 81211-05 Front Burner 40860 VF Top 81211-12 VF Valve Tube 40857 Left Side 81202 Control Valve (LP) 40856 Right Side 81198 Control Valve (NAT) 27225 Side Log Retainer 89761 Piezo Ignitor 27222 Rear Log Support...
  • Page 22: Service Record

    SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
  • Page 23: Limited Lifetime Warranty

    A list of Everwarm authorized dealers is Limited available on the Everwarm branded websites. Burners 3 yrs Lifetime • This warranty is only valid while the Everwarm appliance Combustions chamber, heat remains at the site of original installation. Limited exchangers and factory-installed 3 yrs Lifetime •...
  • Page 24: Liability Limitations

    Everwarm • Changes in surface finishes because of normal use. As a ’s sole and absolute discretion. In no event will Everwarm heating appliance, some changes in color of interior and be liable for any incidental or consequential damages. THE exterior surface finishes may occur.

This manual is also suitable for:

Ewvfs32pvEwvfs32

Table of Contents