OWNER’S MANUAL UNIBOOST SERIES Questions, problems, missing parts? Before returning to the store, call Customer Service 8 a.m. - 5 p.m., EST, Monday - Friday 815-675-7000 or email customersupport@intermatic.com Intermatic.com Thermally Protected 230/115 V Available for Indoor/Outdoor Use 5.8/11.6 A...
Safety Information DESCRIPTION CALIFORNIA PROPOSITION 65 The UNIBOOST non-self priming Booster Pump provides suction side WARNING: This product may contain chemicals known to pool cleaners with high pressure water to maximize cleaning results. the State of California to cause cancer and birth defects or other reproductive harm.
Pools and spas located indoors must comply with ANSI/ASHRAE (American Society of Heating, Refrigeration and Air-Conditioning Engineers) standard 62-2001 to ensure adequate ventilation and safe use. WARNING SIGNS Protect your family and guests. Make sure that all warning signs provided by the manufacturer, builder, or installer are displayed according to the manufacturer’s specifications. Figure 2 Intermatic.com...
Installation WARNING: Shock Hazard! Only qualified, licensed personnel should install pump and wiring. A professional trained and familiar with pool pump installation must perform pressure tests. TOOLS REQUIRED PTFE Phillips Safety Hose Wrench (Teflon ™ screwdriver Goggles Cutters Tape INSTALLATION INSTRUCTIONS The pump mount must be located away from corrosive or flammable chemicals.
Voltage at the motor must be within 10% of the motor nameplate rated voltage or the motor may overheat, causing overload tripping and reduced component life. Verify voltage is correct before applying power. If voltage does not fall within the specified range during operation consult the power company. BOOSTER Pump Wiring Diagram Intermatic.com...
NOTE: If you do not use conduit when wiring motor, be sure to seal wire opening on end of motor to prevent dirt, bugs, etc. from entering.. MOTOR HP BRANCH FUSE MAX. LOAD AMPS VOLTAGE/HZ/PHASE SERVICE TO MOTOR - DISTANCE IN FT. RATING AMPS* 0-100’ 101-200 AWG WIRE SIZE 11.6 115/60/1 230/60/1 Wire Gauge Matrix For UNIBOOST Series Pumps...
WARNING: Risk of electric shock . Can shock, burn or kill. Disconnect power before working on pump or motor TO PREVENT PUMP FROM FREEZING, REMOVE TRAP COVER AND DRAIN THE TANK BODY THROUGH THE TWO DRAIN PLUGS PROVIDED. CLEAN PUMP THOROUGHLY; REPLACE TRAP COVER. Intermatic.com...
Page 10
Use only non-toxic antifreeze. Do not use automotive antifreeze. It is highly toxic and may damage plastic components in the system. UNIBOOST Series Pump Drain Plugs STORAGE / WINTERIZING NOTICE Allowing pump to freeze will damage pump and void warranty! NOTICE Do not use anti-freeze solutions (except propylene glycol) in your pool/spa system.
Check for loose connections. • The pump may be too hot. A. Check line voltage; if less than 90% or more than 110% of rated voltage consult a licensed electrician. B. Increase ventilation. C. Reduce ambient temperature. D. Tighten any loose connections. Intermatic.com...
Replacement Parts FOR REPLACEMENT PARTS OR TECHNICAL ASSISTANCE, PLEASE CALL 815-675-7000 Please provide the following information: □ Model number □ Serial number □ Part description and number as shown in parts list BOOSTER Series Pump Replacement Parts PART NUMBER NAME 14421 Drain Plug O-Ring 55001-001...
Please call the manufacturer at 815-675-7000 for service or return authorization and instructions. DO NOT MAIL THIS FORM TO THE MANUFACTURER. Use this form only to maintain your records. MODEL NO. _____________________ SERIAL NO. _____________________ INSTALLATION DATE __________________________ Intermatic.com...
Page 14
Questions, problems, missing parts? Call Customer Service 8 a.m.- 5 p.m., EST, Monday-Friday 815-675-7000 or email customersupport@intermatic.com Intermatic.com Retain this manual for future use. 158--02634...