Do you have a question about the 5L Eco-Flow and is the answer not in the manual?
Questions and answers
Summary of Contents for Dewhot 5L Eco-Flow
Page 1
5L Eco-Flow Low Pressure Gas Geyser Type A - LPDH5 Install outdoors only - must be installed with a weather box (cover)
Page 2
Guarantee After installation, please register your Burn-back product on the Dewhot website. In the event of a burn-back, where the You will need your invoice and Certificate flame burns back to the jet, immediately turn the gas supply off at the gas cylinder.
Register your product warrantyportal.dewhot.com Create a profile on our warranty portal. Access the warranty terms and proceedures. You will have immediate access to your product history and easily be able log faults or talk to a technician. Parts Diagram Oxygen...
5L/min Max Gas Consumption 0.8 Kg/h Unit Size 435 X 290 X 165mm Unit Weight 4.7 Kg 2 x 262cm Required Ventilation ( 1 at high and 1 at low level) Page 4 of 24 Dewhot | Gas geyser manual...
This water heater shall not be connected installations must have a weather box. to a flue WATER-CONTROLLED AUTOMATIC IGNITION This unit has a water flow sensor that will immediately ignite the burner when detecting water flow Page 5 of 24 Dewhot | Gas geyser manual...
Page 6
1.5 to 2 minutes 55°C +/- 30 seconds 57°C +/- 10 seconds 60°C less than 5 seconds 63°C less than 3 seconds 66°C +/- 1.5 to 2 seconds 69°C +/- 1 second Page 6 of 24 Dewhot | Gas geyser manual...
Page 7
5. The COC should be issued and signed 2. Do not ignite any appliance. after the installation has been inspected. 3. Do not touch any electrical switch. 4. Evacuate the house immediately with your family and pets. Page 7 of 24 Dewhot | Gas geyser manual...
2. With inlet water temperatures above 0°C, but not exceeding 45°C 3. Free of lime and scale deposits 4. DO NOT reverse the hot and cold water connections, this will not allow the gas geyser to function. Page 8 of 24 Dewhot | Gas geyser manual...
Operation of the gas geyser requires a 4. Once the appliance is operating, the minimum water pressure of 20Kpa and a minimum water flow rate of 1 Litre/min. factory connections also need to be tested for leaks. Page 9 of 24 Dewhot | Gas geyser manual...
Installation of demountables is recommended on the hot and cold water lines, so that the gas geyser may easily be disconnected for servicing. Page 10 of 24 Dewhot | Gas geyser manual...
Page 11
5. Appliances in the vicinity should be shut off to avoid vapours igniting from the gas burner. Flammable vapours can be drawn by air currents from surrounding areas to the inlet of gas geyser. Page 11 of 24 Dewhot | Gas geyser manual...
Page 12
SANS 10087:1. If you are unsure please call the Dewhot offices to clarify. 3. You can now open the gas cylinder and any gas shut off valves installed on the gas line. There may be an air 7.
• The body of the gas geyser can get hot during operatuon, do not touch any part of the gas geyser, except for the gas and water control knob. Page 13 of 24 Dewhot | Gas geyser manual...
Page 14
The gas geyser is fitted with a device that will shut off the gas supply to the burner Page 14 of 24 Dewhot | Gas geyser manual...
Page 15
If the temperature is below 39°C or lower than what you would like to shower with, slow down the water flow, bit by bit, until the temperature is comfortable enough to shower as set out on page 16. Page 15 of 24 Dewhot | Gas geyser manual...
This is highly advised and can be cleaned once a year. performed at any location inland or coastal. Perform regular maintenance on the Do not perform this step if the geyser is on. Page 16 of 24 Dewhot | Gas geyser manual...
• Turn on the second the cold freezing temperatures over this period. water supply. After a long shut-down period, the gas geyser needs to be serviced and checked. Page 17 of 24 Dewhot | Gas geyser manual...
Page 18
The water flow may be too high Only 35-38 degrees reached The regulator may be undersupplying gas, Check the gas inlet pressure is operating at 2,8 kPa while on the LCD screen the applinace is running Page 18 of 24 Dewhot | Gas geyser manual...
Page 19
Temperature sensors are faulty on the radiator but dies immediately after less than 1 second or so One of the two solenoids may be faulty. Page 19 of 24 Dewhot | Gas geyser manual...
Page 20
Clean out the burners and jets and all black soot soot building up around the top with a degreaser. of the geyser Page 20 of 24 Dewhot | Gas geyser manual...
Page 21
These geysers may also be Donkeys inherently live outdoors but installed outdoors. more aligned with the old donkey water heaters which were steel water tanks installed over a fire outdoors. Page 21 of 24 Dewhot | Gas geyser manual...
Page 22
Once an installation is Before you sign off the installation, make complete you are required to brief, in full, sure you also receive your COC the operational and safety functions of the unit. Page 22 of 24 Dewhot | Gas geyser manual...
Page 23
This will also give you the ability to log faults, view terms & procedures or talk to a technician. The Dewhot Difference We care, we share, we evolve Page 24 of 24 Dewhot...