BM HOSPITAL BASSINET BM SERIES USER MANUAL Department of Medical Technology TECH-MED Sp. z o. o. ul. Ernsta Petersona 6a, 85-862 Bydgoszcz Phone: (52)/373 19 14, (52) 360 58 50 ÷ 89, (52)/363 79 94, Fax: (52)/360 58 80, email: techmed@techmed.com.pl www.techmed.com.pl NIP 953 22 86 409, District Court in Bydgoszcz, 13th Commercial Division of the National Court Register, KRS (National Court Register) No.
Page 2
1. PURPOSE AND SCOPE OF USE OF THE HOSPITAL BASSINETS BM series hospital bassinets are used as a sleeping place for the newborns and are intended for performing nursing activities by the medical personnel and the mother of the newborn during its first days of life. A hospital bassinet is essential equipment of maternity and neonatal units, nursing stations, neonatal rooms or rooming-in.
Issue date 18-10-2023 Zakład Techniki Medycznej BM HOSPITAL BASSINET Edition I/23 “Tech-Med” Sp. z o.o. ul. Ernsta Petersona 6a Page 2 USER MANUAL 1434 85-862 Bydgoszcz, Poland Positioning element Fig. 2. Reverse Trendelenburg positioned cradle view. 3. TECHNICAL CHARACTERISTICS Outer dimensions [mm] Type of Material Castors...
Page 4
4. USAGE BM series hospital bassinet should be used in accordance with the intended use specified in paragraph 1. Persons other than the medical personnel caring for the newborns must be trained in the use of the product by the medical personnel before using it.
Do not move the bassinet with an open drawer or cabinet door (applies to the BM2 bassinets). 5. STORAGE AND UNPACKING BM series hospital bassinet is delivered to the recipient in the assembled state. The manufacturer’s packaging protects the product against precipitation, violent shocks and mechanical damage during normal transport conditions. Until the tables are put into use, they should be stored in the factory packaging in a room with a temperature of +10°C to...
10. DESCRIPTION AND ASSESSMENT OF RESIDUAL RISK The BM series hospital bassinet has been designed and constructed in accordance with the current state of knowledge and technology as well as relevant legal and standards. Despite the manufacturer's efforts to ensure safety and eliminate hazards when using the bassinet, some elements of risk during its use are impossible to avoid.
Page 8
Issue date 18-10-2023 Zakład Techniki Medycznej BM HOSPITAL BASSINET Edition I/23 “Tech-Med” Sp. z o.o. ul. Ernsta Petersona 6a Page 7 USER MANUAL 1434 85-862 Bydgoszcz, Poland • Providing the mother of the newborn with information on the proper use of the device by medical personnel •...
Page 9
Issue date 18-10-2023 Zakład Techniki Medycznej BM HOSPITAL BASSINET Edition I/23 “Tech-Med” Sp. z o.o. ul. Ernsta Petersona 6a Page 8 USER MANUAL 1434 85-862 Bydgoszcz, Poland Fig. 3. BM0 Fig. 4. BM0 bassinets prepared for storage Fig. 5. BM1 Fig.
Page 10
Issue date 18-10-2023 Zakład Techniki Medycznej BM HOSPITAL BASSINET Edition I/23 “Tech-Med” Sp. z o.o. ul. Ernsta Petersona 6a Page 9 USER MANUAL 85-862 Bydgoszcz, Poland...