ccei Limpido Pro easy 60 Manual
ccei Limpido Pro easy 60 Manual

ccei Limpido Pro easy 60 Manual

High-performance, robust electromechanical salt electrolyser (cell not supplied)

Advertisement

Quick Links

Table of Contents

1. Pack contents ............................................................................................................................... 2
2. Operation .................................................................................................................................... 2
3. Technical specifications ................................................................................................................... 3
4. Description ....... ........................................................................................................................... 4
4.1. The principles of electrolysis .................................................................................................. 4
4.2. Cell lighting ....................................................................................................................... 5
5. Installation ................................................ ................................................................................... 6
5.1. Hydraulic installation ............................................................................................................ 6
5.2. Connection to electricity ........................................................................................................ 8
6. Start up ............................................................................................. ........................................ 10
6.1. Stabiliser ......................................................................................................................... 10
6.2. Salt level check ................................................................................................................. 11
6.3. Control of theTH ............................................................................................................... 11
6.4. pH checks ........................................................................................................................ 12
7. Maintenance ............................................................................................................................... 13
7.1. Adding salt ...................................................................................................................... 13
7.2. Wintering ...................... .................................................................................................. 13
7.3. Cell cleaning .................................................................................................................... 14
A. Declaration of conformity ............................................................................................................. 15
MPNT0531 1.0EN (20/05/2024)
Limpido PRO EASY
High-performance, robust electromechanical
salt electrolyser (cell not supplied)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Limpido Pro easy 60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ccei Limpido Pro easy 60

  • Page 1: Table Of Contents

    Limpido PRO EASY High-performance, robust electromechanical salt electrolyser (cell not supplied) Table of Contents 1. Pack contents ..........................2 2. Operation ............................ 2 3. Technical specifications ........................3 4. Description ..........................4 4.1. The principles of electrolysis ....................4 4.2.
  • Page 2: Pack Contents

    Limpido PRO EASY 1.0EN Technical Read these instructions carefully before installing, commissioning and using this product. 1. Pack contents The PFXCEL09, PFXCEL10 and PFXCEL11 cells are not supplied with the box. • 1 Limpido PRO EASY electrolyser box • 1 flow detector •...
  • Page 3: Technical Specifications

    Limpido PRO EASY 1.0EN Technical 3. Technical specifications 230V~ AC 50Hz/60Hz on a permanently powered socket protected by a 30 mA ground Power supply voltage fault circuit breaker The LIMPIDO PRO EASY box is designed to run with 3 electrolysis cell models: The PFXCEL09 cell model (identified as PRO-60 on the box) provides for chlorine production of around 12-15 g/h The PFXCEL10 cell model (identified as PRO-90 on the box) provides for chlorine...
  • Page 4: Description

    Limpido PRO EASY 1.0EN Technical 4. Description 4.1. The principles of electrolysis Salt water electrolysis separates salt (NaCl) into sodium (Na) and Chlorine (Cl). The chlorine is immediately dissolved in the water to produce hypochlorous acid (HClO). This powerful disinfectant destroys bacteria and algae before turning back into salt. The quantity of chlorine needed to disinfect a swimming pool increases with the water temperature and pH.
  • Page 5: Cell Lighting

    Limpido PRO EASY 1.0EN Technical 4.2. Cell lighting The cell has built-in lighting making it possible to check the polarity applied to the cell and to illuminate the bubbles exiting the cell when chlorine is produced. Positive (normal) production = blue Negative (reverse) production = green When switched off or during the polarity reversal time, the cell is switched off.
  • Page 6: Installation

    Limpido PRO EASY 1.0EN Technical 5. Installation 5.1. Hydraulic installation The various components that need to be positioned on the pool pipe are: the electrolysis cell , the flow detector (located upstream of the cell but on the same section of pipe), the earth electrode. The earth electrode is not supplied with the LIMPIDO PRO EASY, but it is strongly recommended that one is fitted to the pipe and connected to an independent earth rod planted in the wet soil.
  • Page 7 Limpido PRO EASY 1.0EN Technical 5.1.2. Earth electrode The Pool-Terre device not supplied with the Limpido PRO EASY, is used to discharge the electrostatic charges in the water to the earth. When this system is connected to a “proper earth” (the connection must be direct to a local earth electrode), it eliminates leakage current and limits the reduction-oxidation phenomena that cause corrosion.
  • Page 8: Connection To Electricity

    Limpido PRO EASY 1.0EN Technical 5.2. Connection to electricity Installation of this project involves a hazard of electric shocks. We strongly recommend you contract a professional installer. Incorrect installation puts you in danger and may irreversibly damage the product and the equipment connected to it. For safety reasons and in accordance with the NF C15-100 standard, the Limpido PRO EASY box must be installed •...
  • Page 9 Limpido PRO EASY 1.0EN Technical 5.2.1. Electrolysis coupling contact The contact to be connected to the two identified terminals MUST be a DRY CONTACT. Remove the jumper on the box if you want to replace it with an external dry contact. The contact to be connected to the two identified terminals can have a dual role •...
  • Page 10: Start Up

    Limpido PRO EASY 1.0EN Technical 6. Start up The device settings can only be adapted through regular analysis. Following the steps described below carefully makes it possible to start up without experiencing any issues. The chemicals used in pools are highly corrosive and can have a harmful effect on health and the environment.
  • Page 11: Salt Level Check

    Limpido PRO EASY 1.0EN Technical 6.2. Salt level check The Limpido PRO EASY is designed to operate with a water conductivity corresponding to a salinity level of 3g/l at 25°C. To accurately check your pool water’s salt level, we recommend using a conductivity meter. This easy-to-use instrument gives a direct salt level reading in g/l.
  • Page 12: Ph Checks

    Limpido PRO EASY 1.0EN Technical 6.4. pH checks pH, or potential Hydrogen, measures the acidity of the water. Its value is between 0 and 14. A solution with a pH of 7 is neutral. If the pH is below 7 the solution is acid, and if it is above 7 it is basic (or alkaline). For the comfort of bathers, effective treatment and reliability of the installation, the swimming pool water’s pH must be kept at about 7.2.
  • Page 13: Maintenance

    Limpido PRO EASY 1.0EN Technical 7. Maintenance 7.1. Adding salt When the salt level drops below 2 g/l, salt must be added. The use of specially treated salt containing stabilisers for pools is recommended. This will significantly improve the effective- ness of the Limpido PRO EASY.
  • Page 14: Cell Cleaning

    Limpido PRO EASY 1.0EN Technical 7.3. Cell cleaning When the indicated production remains low despite a correct salt level, check the cell condition and clean it if any scale is visible on the plates. This operation must be carried out with the greatest care, and it is essential to follow the in- structions for the use of the acid.
  • Page 15: Declaration Of Conformity

    Limpido PRO EASY 1.0EN Technical A. Declaration of conformity CCEI (FR47403521693) declares that the Limpido PRO EASY product meets the safety and elec- tromagnetic compatibility requirements of European directives 2014/35/EU and 2014/30/EU. Jérémy Vauquelin Marseilles, on 20/05/2024 Distributor's stamp Date of sale: ..... . . Batch N°: ......

This manual is also suitable for:

Limpido pro easy 90Limpido pro easy 120Pf101098

Table of Contents