Carrier AGAGC8NPS01C Installation Instructions Manual

Carrier AGAGC8NPS01C Installation Instructions Manual

Gas conversion kit, natural-to-propane

Advertisement

AGAGC8NPS01C
Gas Conversion Kit, Natural-to-Propane
Non-Condensing (80%) Furnace
45,000 BTUh to 155,000 BTUh Models Only
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATION
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or death.
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire,
explosion, or production of carbon monoxide could result causing
property damage, personal injury, or loss of life. The qualified service
agency is responsible for the proper installation of this furnace with this
kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer's
instructions supplied with the kit.
AVERTISSEMENT
!
LE FEU, L'EXPLOSION, CHOC ELECTRIQUE,
ET MONOXYDE DE CARBONE EMPOISONNER
Cette trousse de conversion doit être installée par un servie d'entretien
qualifié, selon les instructions du fabricant et selon toutes les exigences
et tous les codes pertinents de l'autorité compétente. Assurezvous de
bien suivre les instructions dans cette notice pour réduire au minimum
le risque d'incendie, d'explosion ou la production de monoxyde de
carbone pouvant causer des dommages matériels, de blessure ou la
mort. Le service d'entretien qualifié est responsable de l'installation de
cette trousse. L'installation n'est pas adéquate ni complète tant que le
bon fonctionnement de l'appereil converti n'a pas été vérfié selon les
instructions du fabricant fornies avec la trousse.
Installing and servicing heating equipment can be hazardous due to gas
and electrical components. Only trained and qualified personnel should
install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions such as
cleaning and replacing air filters. Trained service personnel must
perform all other operations. When working on heating equipment,
observe precautions in the literature, on tags, and on labels attached to or
shipped with the unit, and other safety precautions that may apply.
Follow all safety codes. In the United States, follow all safety codes
including the current edition of the National Fuel Gas Code (NFGC)
Installation Instructions
A200203
NFPA No. 54/ANSI Z223.1. In Canada, refer to the current edition of the
National Standard of Canada, Natural Gas and Propane Installation
Codes (NSCNGPIC), CAN/CSA-B149.1 and 2. Wear safety glasses and
work gloves. Have a fire extinguisher available during start-up,
adjustment steps, and service calls.
Recognize safety information. This is the safety-alert symbol
you see this symbol on the furnace and in instructions or manuals, be
alert to the potential for personal injury. Understand the signal words
DANGER, WARNING, CAUTION and NOTE. The words DANGER,
WARNING, and CAUTION are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which could
result in personal injury or death. CAUTION is used to identify unsafe
practices which may result in minor personal injury or product and
property damage. NOTE is used to highlight suggestions which will
result in enhanced installation, reliability, or operation.
INTRODUCTION
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK AND
CARBON MONOXIDE POISONING HAZARD
Failure to follow instructions could result in personal injury, death or
property damage.
Improper installation, adjustment, alteration, service, maintenance, or
use can cause carbon monoxide poisoning, explosion, fire, electrical
shock, or other conditions, which could result in personal injury or
death. Consult your distributor or branch for information or assistance.
The qualified installer or agency must use only factory-authorized kits
or accessories when servicing this product.
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Gas supply MUST be shut off before disconnecting electrical power
and proceeding with conversion.
WARNING
!
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Before installing, modifying, or servicing system, main electrical
disconnect switch must be in the OFF position and install a lockout tag.
There may be more than one disconnect switch. Lock out and tag
switch with a suitable warning label. Verify proper operation after
servicing.
. When

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGAGC8NPS01C and is the answer not in the manual?

Questions and answers

Summary of Contents for Carrier AGAGC8NPS01C

  • Page 1 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane Non-Condensing (80%) Furnace 45,000 BTUh to 155,000 BTUh Models Only Installation Instructions NFPA No. 54/ANSI Z223.1. In Canada, refer to the current edition of the National Standard of Canada, Natural Gas and Propane Installation Codes (NSCNGPIC), CAN/CSA-B149.1 and 2. Wear safety glasses and work gloves.
  • Page 2: Description And Usage

    AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions TWO-STAGE & VARIABLE CAUTION NON-CONDENSING FURNACES Table 3 – Model Numbers Beginning with: UNIT OPERATION HAZARD 58CV 58CT 58T(N/P) 31(2/4/5) Failure to follow this caution may result in unit damage or improper 82(0/1)T...
  • Page 3 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions MANIFOLD/ORIFICE/BURNER REMOVAL WARNING CAUTION FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD UNIT OPERATION HAZARD Failure to follow this warning could result in personal injury, death or Failure to follow this caution may result in unit damage or improper property damage.
  • Page 4 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions NOx DEVICE REMOVAL ORIFICE SELECTION/DERATE CAUTION CAUTION UNIT DAMAGE HAZARD UNIT DAMAGE HAZARD Failure to follow this caution may result in unit damage. Failure to follow this caution may result in unit damage.
  • Page 5 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions TWO STAGE GAS VALVE A221044 Fig. 6 – Conversion Kit Rating Plate INSTALL ORIFICES REINSTALL BURNER ASSEMBLY 1. Install main burner orifices. Do not use PTFE thread-seal tape. To reinstall burner assembly: Finger-tighten orifices at least one full turn to prevent 1.
  • Page 6 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions Two Stage Gas Valve WARNING NOTE: For older model 2-stage furnaces with a Series E gas valve (see Fig. 11), they DO NOT need to have the regulator springs replaced in the ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD...
  • Page 7 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions 7. Turn low-heat stage adjusting screw clockwise (inwards) 9.5 turns. 2. Remove 1/8-in. (3 mm) pipe plug from inlet pressure tap on gas This will increase the manifold pressure closer to the low-heat set valve.
  • Page 8 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions 1. Locate the orange wire in the kit with an insulated straight female 1. Jumper R-W thermostat connections on control. spade terminal and an insulated straight male terminal on the other 2. When main burners ignite, confirm inlet gas pressure is between end.
  • Page 9: Electrical Shock Hazard

    AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions Fixed-Speed Blower (FCT), Two-Stage Gas Valve SET UP SWITCHES THERMOSTAT TYPE (TT) AND HEAT OFF- DELAY TWINNING AND/OR COMPONENT TEST TERMINAL 24- V THERMOS TAT TERMINALS TEST / TWIN HUMIDIFIER TERMINAL 24VAC (24 VAC 0.5 AMPS MAX)
  • Page 10: Check Inlet Gas Pressure

    AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions CHECK INLET GAS PRESSURE AVERTISSEMENT CAUTION RISQUE D’EXPLOSION ET D’INCENDIE UNIT DAMAGE HAZARD Le fait de ne pas suivre cet avertissement pourrait entraîner des dommages corporels et / ou la mort. Failure to follow this caution may result in unit damage.
  • Page 11 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions Two-Stage Gas Valve 5. Turn adjusting screw counterclockwise (out) to decrease manifold pressure or clockwise (in) to increase manifold pressure. CAUTION 6. Replace gas valve regulator seal cap. 7. Verify manifold pressure is correct.
  • Page 12 AGAGC8NPS01C Gas Conversion Kit, Natural-to-Propane: Installation Instructions 22. See Sequence of Operation in furnace Installation, Start-Up, and the gas pressure at switch drops below low gas pressure switch setting, Operating Instructions. and switch opens. Any interruption in control circuit (in which low gas pressure switch is wired) quickly closes gas valve and stops gas flow to 23.

Table of Contents