Summary of Contents for Storz UNIDRIVE Select

  • Page 1 Instructions for use UNIDRIVE Select...
  • Page 2 03-2024 Copyright © All product illustrations, product descriptions, and texts are the intellectual property of KARL STORZ SE & Co. KG. Their use and reproduction by third parties require the express approval of KARL STORZ SE & Co. KG. All rights reserved.
  • Page 3: Table Of Contents

    5 Preparation  ............................24 5.1 Unpacking the product  ......................24 5.2 Reprocessing the product  ......................24 5.3 Testing the product ........................24 5.4 Setting up the product  ....................... 24 5.5 Connecting the product  ......................25 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 4 Table 1 – Compliance level for immunity tests  ............. 53 9.3.2 Table 2 – Test levels for proximity fields from RF wireless communications equipment ........................55 9.3.3 Table 3 – Emission class and group  ................56 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 5 10.1 Troubleshooting  ......................... 57 10.2 Software messages ........................57 11 Appendix  ............................58 11.1 Appendix: Possible combinations – UNIDRIVE Select  .............. 58 11.2 Attaching the adaptor (28200DXA)  .................... 65 11.3 Footswitch functions according to discipline  ................66 12 Overview of mitigating warnings  ....................70 13 Subsidiaries ...
  • Page 6: General Information

    ü Prerequisite that must be met before carrying out an action. Step 1 ð Interim result of an action Step 2 ð Result of a completed action Actions in safety notes or in the case of a single step: Step 1 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 7: Description Of Warning Messages

    1.6 Abbreviations Abbreviation Explanation ARTHRO Arthroscopy Computed tomography Gynecology Ears, nose, and throat medicine Magnetic resonance tomograph NEURO Neurosurgery RFID Radio frequency identification SPINE Vertebral column Urology OMFS Oral-maxillofacial surgery Central nervous system Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 8: Normal Use

    2.4 Clinical benefits Motor control unit KARL STORZ UNIDRIVE Select regulates and controls the use of motors and further application parts for abrasive procedures in minimally invasive surgery. The modern procedures like spine, neuro, craniofacial and ENT surgery do not take place anymore without powered abrasion.
  • Page 9: Intended Conditions Of Use

    Several minutes to several hours a day Place of installation Positioning on a level, vibration-free surface Mobility – Can be moved if placed on a cart. – Can be swiveled if installed on ceiling supply units. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 10: Safety And Warning

    Local regulations take precedence over IEC and ISO standards. If you have any questions, please contact your local KARL STORZ representative or technical customer support. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 11: Risk Of Explosion And Fire

    IEC standards. Use either the power cord supplied by KARL STORZ or a power cord which has the same properties and which bears a national mark of conformity.
  • Page 12: Damage Due To Ingress Of Liquid In Electrical Components

    If the functionality of the touch screen is limited, the product cannot be used correctly. Patients, users, and third parties may be injured. Do not use the product if the touch screen is defective. Do not tap the touch screen in several places at the same time. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 13: Product Description

    4 Product description 4.1 Description of operation The KARL STORZ motor system UNIDRIVE Select is universally applicable in the ARTHRO, GYN, HNO, NEURO, SPINE, and URO application areas due to the use of separate brushless high- performance electronic motors or brushless high-performance electronic motors integrated in the handpiece.
  • Page 14: Product Overview

    Product description 4.2 Product overview  UNIDRIVE Select – front view Standby button Connection sockets for motor and hand- piece TFT touch screen Connection socket for footswitch  UNIDRIVE Select – rear view Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 15: Possible Combinations

    DrillCut-X II Spine Handpiece 28712050 Instruments 41201FD, 41301FD, 41301D Software License UM603 DrillCut-X II Shaver Handpiece 40712050, 40712055 with shaver blades see chapter Appendix [p. 58] and sinus burr see chapter Appendix [p. 58] Software License UM601 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 16: Technical Data

    Electrical protection class Applied part type according to IEC 60601-1 Degree of protection acc. to IEC 60259 IPX1 (protection from dripping water) Dimensions (L x H x W) 380 x 125 x 305 mm Weight 4.3 kg Operating mode Intermittent duty (in connection with instrument) Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 17 Maximum speed 12,000 rpm (±10%) Start-up maximum speed 12,000 rpm (±10%) Rotation mode Rotation DrillCut-X II – shaver Minimum speed 300 rpm (±10%) Maximum speed 7,000 rpm (±10%) Start-up maximum speed 7,000 rpm (±10%) Rotation mode Oscillation Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 18 1,500 rpm (±10%) Maximum speed 35,000 rpm (±10%) Start-up maximum speed 35,000 rpm (±10%) Rotation mode Rotation DrillCut-X II Spine Minimum speed 300 rpm (±10%) Maximum speed 12,000 rpm (±10%) Start-up maximum speed 12,000 rpm (±10%) Rotation mode Rotation Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 19 1,000 rpm (±10%) Maximum speed 8,000 rpm (±10%) Start-up maximum speed 8,000 rpm (±10%) Rotation mode Rotation DrillCut-X URO Minimum speed 500 rpm (±10%) Maximum speed 5,000 rpm (±10%) Start-up maximum speed 5,000 rpm (±10%) Rotation mode Oscillation Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 20: Symbols Employed

    Consult the printed or electronic instructions for use Note for the user to consult the instructions for use for important cautionary in- formation such as warnings and precautions. Fragile, handle with care Keep dry Temperature limit Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 21: Symbols On The Product

    The color may differ on the product. The symbol is black/white on the packag- ing label. Ready/standby button Applied part type BF Connection socket, e.g., for footswitch Potential equalization connector Ethernet Dangerous voltage Danger of an electric shock! Fuse Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 22: Symbols On The Type Plate

    The EU directives relevant to the product can be found in the EU Declaration of Conformity, which can be requested from KARL STORZ. 4.5.4 Symbols on the user interface Symbol Meaning Forward mode Reverse mode Oscillation Two-pedal footswitch One-pedal footswitch Settings Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 23: Ambient Conditions

    Storage and transport conditions Temperature -15°C ... +60°C (5°F ... 140°F) Relative humidity 5–85% (non-condensing) Air pressure 600–1,080 hPa Average life cycle 5 years Operating conditions Temperature 10°C ... 30°C (50°F ... 86°F) Relative humidity 30–75% Air pressure 700–1,080 hPa Max. operating altitude 3,000 m Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 24: Preparation

    This product and connected components may only be used in medical rooms with electrical installations that conform to applicable national regulations. Set the product down on a horizontal, flat surface or a video cart. Install the product out of reach of patients. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 25: Connecting The Product

    Connect the potential equipotential cable. Connect the power cord. Push the power plug fully into the power socket. ð The standby button lights up white. Connect the Ethernet cable for combination with ENDOMAT SELECT (UP220). Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 26: Putting The Product Into Operation

    ü The footswitch is connected. ü An application instrument is connected. ü Applications for ENT, NEURO, SPINE, ARTHRO, GYN: The ENDOMAT SELECT (UP220) is connected. ü Applications for URO: The S-PILOT (UP501) is connected. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 27 ð If no application instrument or motor is connected, the following start screen appears: ð If an application instrument/motor is connected, a screen appears prompting you to select the handpiece. For the DrillCut-X II-35, for example, this appears: Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 28: Putting The Pump Into Operation

    Tap the Arrow symbol again to collapse the handpiece selection. ð The selected handpiece appears as a presetting when the handpiece selection is expanded again. If a KARL STORZ pump is not being used, close the message. ð The following message appears: Put the pump used into operation.
  • Page 29 ü The UNIDRIVE SELECT is switched on and connected to the ENDOMAT SELECT (UP220). Install the tubing set on the ENDOMAT SELECT (UP220). Make sure that the pump tubes are not crushed. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 30 Connect the tubing ends with the irrigation bag (puncture needle) or with the irrigation connector on the instrument (LUER lock). To remove the tubing set, turn the pump lever clockwise to the 9 o'clock position. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 31: Application

    Connect the motor, see chapter Connecting the product [p. 25]. ð The following screen appears: Tap on the Arrow to expand the handpiece selection. Select the High-speed handpiece to call up the high-speed burr selection. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 32: Drillcut-X Ii-35

    Set the speed, see chapter Setting the speed [p. 37]. 6.1.2 DrillCut-X II-35 Connect the motor, see chapter Connecting the product [p. 25]. ð The following screen appears: Tap on the Arrow to expand the handpiece selection. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 33 Application Select the desired handpiece. ð The following screens appear: Set the speed, see chapter Setting the speed [p. 37]. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 34: Intra Motor

    Connect the motor, see chapter Connecting the product [p. 25]. ð The following screen appears: Tap on the Arrow to expand the handpiece selection. Select the Micro saws to call up the saw selection. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 35: Micro Ear Burr

    Set the speed, see chapter Setting the speed [p. 37]. 6.1.5 Perforator Connect the motor, see chapter Connecting the product [p. 25]. ð The following screen appears: Set the speed, see chapter Setting the speed [p. 37]. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 36: Drillcut-X Arthro

    Application 6.1.6 DrillCut-X ARTHRO Connect the adaptor (28200DXA) to the DrillCut-X ARTHRO (28200DX). Connect the motor to the UNIDRIVE Select using the adaptor (28200DXA). ð The following screen appears: Select the desired mode. Set the speed, see chapter Setting the speed [p. 37].
  • Page 37: Drillcut-X Ii Gyn

    Select the handpiece, e.g., High-speed burr 80k, see chapter Selecting the handpiece [p. 31]. ð The handpiece screen appears with the maximum speed value: Tap the speed value. ð The Minus button appears: Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 38: Changing The Direction Of Rotation

    ð The set speed value appears on the screen after a few seconds. 6.3 Changing the direction of rotation Select the handpiece, e.g., High-speed burr 80k, see chapter Selecting the handpiece [p. 31]. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 39: Selecting The Motor Connection

    When rotary instruments are used, the instruments may smear, clog or move erratically if not irrigated sufficiently. As a result, increased heat may be generated, causing injury to patients, users or third parties. Please ensure sufficient irrigation. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 40: Operating The Footswitch

    Alternatively, set the irrigation flow using the footswitch, see chapter Operating the two-pedal footswitch [p. 40]. 6.6 Operating the footswitch The footswitches have different functions depending on the discipline, see chapter Footswitch functions according to discipline [p. 66]. 6.6.1 Operating the two-pedal footswitch  Two-pedal footswitch, wired Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 41: Operating The One-Pedal Footswitch

    ð This speed varies depending on the pedal position. ð The handpiece is started and the pump runs with the defined irrigation flow rate. 6.6.2 Operating the one-pedal footswitch  One-pedal footswitch, wired Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 42: Settings

    Tap on the Settings button on the top right of the touchscreen. ð The Settings screen appears with the following sub-menus: 6.7.1 Device information In the Settings screen, tap on the Device info sub-menu. ð The Device info screen appears: Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 43: Setting The Language

    In the Settings screen, tap on the Further settings sub-menu. ð The Further settings screen appears: Adjust the Brightness and the Volume with the Plus and Minus buttons. Browse back through the screen with the Arrow. ð The Settings screen appears. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 44: Calling Up The Event Log

    Tap on the desired line to call up the entry on the event. 6.7.5 Setting the pedal control The pedal control determines how the set irrigation flow behaves when the left pedal is pressed briefly. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 45: Setting The Motor Stop Behavior

    Browse back through the screen with the Arrow. ð The Settings screen appears. 6.7.7 Service The Service area is password-protected and can only be accessed by the KARL STORZ technical customer service or authorized persons. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 46: Switching Off The Product

    Application 6.8 Switching off the product Switch off the product with the stand-by button. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 47: Maintenance, Servicing, Repairs, And Disposal

    Patients, users and third parties may be injured as a result of product and accessory degradation. Shut down the product. Have the deficiencies repaired by persons authorized by KARL STORZ. If they are not described in more detail here, maintenance activities may only be performed by KARL STORZ or by a company authorized by KARL STORZ.
  • Page 48 Insert the new fuse. Only use fuses with the same fuse ratings, see chapter Technical data [p. 16]. Introduce the screw inserts into the power fuse holder again. Connect the power supply again. Switch on the product and check that it is working correctly. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 49: Safety Inspection In Accordance With Iec 62353

    Document the results of the safety test. 7.4 Repairing the product Repair work may only be performed by KARL STORZ or by a company authorized by KARL STORZ. The interventions described in this instruction manual are exempt from this rule. Please contact your local KARL STORZ subsidiary or authorized dealer (see the list of subsidiaries).
  • Page 50: Disposing Of The Product

    The product meets the requirements of the Directive on Waste Electrical and Electronic Equipment (WEEE). Within the scope of application of this directive, KARL STORZ SE & Co. KG is responsible for the proper disposal of this product. The product must be disposed of in accordance with the applicable national laws and regulations at a suitable collection point for the reprocessing of electrical and electronic equipment.
  • Page 51: Accessories And Spare Parts

    High-speed micro motor without cable 20362133 Cable for high-speed micro motor, large 20362233 High-speed micro motor without cable 20363133 Cable for high-speed micro motor, small 20363233 INTRA motor 80k, without cable 20261133 INTRA Connecting Cable 20261233 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 52: Electromagnetic Compatibility

    Preferably use the accessories specified in the manual. When using other than those specified in this manual, it becomes the responsibility of the user to determine compliance with IEC 60601-1-2. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 53: Test-Tables

    Dip to 0% for Dip to 0% for fluctuations of the or hospital environment. 1 cycle @ 0° phase 1 cycle @ 0° phase power supply acc. angle angle to IEC 61000-4-11 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 54 8 A/m @ 30 kHz 8 A/m @ 30 kHz close proximity, (CW modulation) (CW modulation) IEC 61000-4-39 65 A/m @ 134.2 kHz 65 A/m @ 134.2 kHz (pulse modulation) (pulse modulation) 7.5 A/m @ 13.56 kHz 7.5 A/m @ 13.56 kHz (pulse modulation) (pulse modulation) Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 55 As an alternative to FM modulation, the carrier may be pulse modulated using a 50% duty cycle square wave signal at 18 Hz. While it does not represent actual modulation, it would be worst case. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 56 Harmonic emissions as per Class A connected to the public low voltage power sup- IEC 61000-3-2 ply network that supplies buildings used for do- mestic purposes. Voltage fluctuations/flicker emis- Complies sions as per IEC 61000-3-3 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 57: Errors And Messages

    Motor not supported Motor cannot be used with – available license Motor defective Connector problems Contact Service Product defective Motorboard defective Contact Service Footswitch defective Pedal defective Contact Service Pedal cannot be calibrated Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 58: Appendix

    41301SN 41304KKBA 41303KKFA 41301KSA 41303KKBA 41301KKSA 41303GNF 41301KKSB 41303GNB 41301LSA Sinus burrs, sterile, single-use products, pack of 5 Sinus Burr 35k Sinus Burr 12k 41335W 41304W 41335RN 41303WN 41335DW 41305RN 41335DT 41305DN Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 59 ARTHRO instruments, sterile, single-use products, pack of 6 Working length 70 mm Working length 120 mm Working length 180 mm 28206AAS 28205ABS 28208BKS 28206ABS 28205ACS 28208DCS 28206CAS 28205ADS 28208EHS 28206CBS 28205AKS 28208IDS 28206DAS 28205BCS 28206DBS 28205CBS 28206FAS 28205CCS 28206FBS 28205CDS Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 60 26205SA Shaver Blade, 3 mm, distally opened 26205SB Shaver Blade GYN 26208SA Shaver Blade GYN 26208SB For DrillCut-X II Morcellator Handpiece URO (27702050) Product name Item number Morcellator Blade, Ø 4 mm, length 40 cm 27056LM Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 61 High-speed diamond burr, Ø 3.1 mm, 95 mm, 360231S 80,000 rpm, single-use product, sterile High-speed diamond burr, rough, Ø 4.0 mm, 360340S 95 mm, 80,000 rpm, single-use product, sterile High-speed diamond burr, rough, Ø 5.0 mm, 360350S 95 mm, 80,000 rpm, single-use product, sterile Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 62 High-speed diamond burr, rough, Ø 3.1 mm, 360331M 125 mm, 80,000 rpm, single-use product, sterile High-speed diamond burr, rough, Ø 4.0 mm, 360340M 125 mm, 80,000 rpm, single-use product, sterile High-speed diamond burr, rough, Ø 5.0 mm, 360350M 125 mm, 80,000 rpm, single-use product, sterile Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 63 High-speed craniotome burr, medium, 15 mm, 362640M 80,000 rpm, single-use product, sterile, in combi- nation with craniotome attachment (362647) High-speed craniotome burr, long, 25 mm, 362640L 80,000 rpm, single-use product, sterile, in combi- nation with craniotome attachment (362648) Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 64 12,000 rpm Diamond micro ear burr, Ø 1.8 mm, reusable, 460218 sterile, 12,000 rpm Diamond micro ear burr, Ø 2.3 mm, reusable, 460223 sterile, 12,000 rpm Diamond micro ear burr, Ø 0.35 mm, reusable, 460203 sterile, 12,000 rpm Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 65: Attaching The Adaptor (28200Dxa)

    ð The adaptor is now correctly attached to the motor system. During servicing, remove the keychain from the attachment plate and replace the adaptor. Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 66: Footswitch Functions According To Discipline

    Button 1 or but- Button 2 Button 1 + Button 2 – Button 3 – 40712035, ton 3 (tap) button 3 (hold for more (tap) 40712535 (pump only) (hold for more than 3 s) 40712050, than 2 s) 40712055 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 67 Button 2 – – – 362640 (hold for more than 3 s) Craniotome Button 1 – – Button 2 Button 2 – – – 362646, (tap) (hold for more 362647, than 3 s) 362648 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 68 Button 2 – – ARTHRO (clockwise) (tap) button 3 (hold for 28200DX or button 3 (hold for more more than (counterclock- than 2 s) 3 s) wise) Button 1 (increase) button 3 (reduce) Button 3 (tap) Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 69 – – Stage 2 1 and stage 2 (tap) 27702050 DrillCut-X II Button 1 Button 1, stage Button 2 – – – – – Stage 2 1 and stage 2 (tap) 26702050 Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 70: Overview Of Mitigating Warnings

    WARNING No modification of this equipment is allowed. WARNING Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 71: Subsidiaries

    E-Mail: info-lt-lv@karlstorz.com Gedik Is Merkezi B Blok, Kat 5, D 38-39, Bagdat Cad. No: 162, Maltepe Istanbul, Turkey Phone: +90 216 442 9500, Fax: +90 216 442 9030 **Sales for Industrial Endoscopy Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 72 No. 8 Commonwealth Lane #03-02, Singapore 149555, Singapore Phone: +65 69229150, Fax: +65 69229155 KARL STORZ ENDOSKOPE – East Mediterranean and Gulf (Offshore) S.A.L. E-Mail: infoasia@karlstorz.com Spark Tower 1st floor Charles Helou St., Horch Tabet – Sin El Fil, Beirut, Lebanon...
  • Page 73 Subsidiaries Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 74 Subsidiaries Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...
  • Page 75 Subsidiaries Instructions for use • UNIDRIVE Select • PCC270_EN_V2.0_03-2024_IFU_CE-MDR...