    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-28HA03/R2 Please read this operation manual before using the air conditioner. No.001050...
  • Page 2 The products are fulfilled with the requirements in the directive of other part must be done by a qualified installer in accor- 2002/95/EEC of the European parliament and of the council dance with relevant local and national legislation.
  • Page 3 L'appareil est conforme à la directive 2002/95/CEE relative à pération du frigorigène, de l'huile et de toute autre partie doi- la limitation de l'utilisation de certains substances dangereu- vent être effectués par un installateur qualifié conformément à...
  • Page 4 Consult your local authorities for the name inoperative and safe. Unplug the air conditioner and address of the waste materials collecting in order to avoid the risk of child entrapment. centers and waste paper disposal services nearest to your house.
  • Page 5: Specifications

    Inadequate repairs Iow impedance. Normally the required impedance is reached at a 32A fusing point. may result in a major source of danger for 2.No other equipment has to be connected: the user of the air conditioner.
  • Page 6: Parts And Functions

    Lights up when Timer operation adjust up and down air flow. Lights up when unit starts. is selected. (Don't adjust it manually.) Actual inlet grille may vary from the one shown in the manual according to the product purchased. Outdoor Unit...
  • Page 7 C/-8 Minimum:D.B/W.B 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F. 3. If the fuse on PC board is broken please change it with the type of T.3.15A/250V.
  • Page 8: Clock Set

    NOTE:(1)The following functions and related displays are not available: AUXILIARY HEAT display, POWER/SOFT display,HEALTH display. (2)If the Air conditioner don't have the function of the code ,press code B can cause it not available. (3)Cooling only unit do not have functions and displays related with heating.
  • Page 9: Operation

    When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press...
  • Page 10 All indicators on indoor unit go out. Vertical flap closed automatically. Hints Remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reselecting is needed.(TIMER ON/OFF needs reselecting)
  • Page 11: Cool,Heat And Dry Operation

    LOW speed regardless of FAN setting. Hints On cooling only unit, heating mode is not available. Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.
  • Page 12 Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7 C.
  • Page 13: Timer Operation

    TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode.
  • Page 14 Follow the same procedures in "Time setting for TIMER ON". (6) Time confirming for TIMER OFF After time setting, press SET button to confirm, "OFF" stops flashing Time displayed: Unit stops at X hour X min. To cancel TIMER mode...
  • Page 15: Emergency And Test Operation

    Removal of the restriction of emergency or test operation: Press once more the emergency operation switch, or manipulate through the remote controller, a "Pi" sound causes the restriction of emergency or test operation to be removed. When the remote controller is manipulated for the removal, then the selected operation...
  • Page 16 Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. In COOL mode One hour after SLEEP mode starts, temp. will become 1 C higher than temp.
  • Page 17: Maintenance

    Cut off power supply before cleaning unit casing with soft cloth. In case of heavy stain, clean it with neutral detergent. squeeze water in the cloth, wipe off the detergent on unit casing completely. Cleaning of remote controller Don't use water to wash unit casing, please use dry cloth.
  • Page 18 Close the inlet Grille Close the Grille surely. The air conditioner which you are using may be different from the upper illustration, please refer to the upper installation methods. NOTE: Please replace the Air Purifying Filter in 3-6 months as standard.
  • Page 19 Avoid time-wasteful operation Never fail to observe the followings Do not sprinkle water over Do not block the inlet or outlet. the unit. Do not pull power plug. Do not use for other purposes. Such as food preservation plant cultivation or animal breeding.
  • Page 20: Troubleshooting

    Performance casing expanding or shrinking because of inspection temperature changes Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated. from the interior air such as the smell of furniture, cigarettes.