This product can not be used for any explosion-proof area. Do not use this product in a situation where human life may be affected. eyc-tech will not bear any responsibility for the results produced by the operators! Warning! ⚫ Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards.
Control valve status Tube expanding state (gas flow becomes large from small) (switch switching / gas flow adjustment) The gas flows continuously through the 90° bend in the Shrinking tube state (gas flow from large to small) same horizontal plane www.eyc-tech.com...
Venturi Thermal Mass Flow Meter 5. RS-485 and Modbus FDM06-I integrate a RS-485 interface for digital communication as an option feature. Based on Modbus protocol makes the general convenience on PLC, HMI and PC connection. For Modbus protocol information please download the file from website.
Operating System requirements:above Windows 7. Other application program requirements:above Microsoft Office 2003 1. Hardware connection:Connect the FDM06-I to PC through USB to RS-485 or RS-232 to RS-485 converter 2. Check the COM port number from Device Manager in Computer Management. e.g.
Page 10
Air Flow Venturi Thermal Mass Flow Meter 4. Scan RS-485 connection Open the FDM06-I UI, go to function "Interface" , click item "Config" and then setting COM port, pressed "Scan" bottom for scan devices and pressed"Close and Export" when the interested devices found.
Page 11
5 digits, and the decimal digits need to occupy integer digits. (6) Range for Display Upper and Lower (7) Alarm Mode: Check the box if analog output pretend a alarm switch output (8) Alarm Trigger Point: Upper and Lower (9) Alarm Output Level: Upper and Lower www.eyc-tech.com...
Page 12
(6) Totalizer Mode: Check the box if relay activate source from flow accumulation counter (7) Set Point:Activation Set Point (8) Hysteresis:Activation Hysteresis Gap (9) Delay On:Relay Activate Delay Time in second (10) Delay Off:Relay Deactivate Delay Time in second (10) www.eyc-tech.com...
Page 13
※ Menu Configuration: (7) Configuration brief (8) Read:Upload the settings of the currently connected device (9) Write:Download the setting of the currently connected device (10) Open:Open configuration file and load the settings (11) Save:Save configuration file ※ Modbus Protocol: (10) (11) www.eyc-tech.com...
Page 14
(7) apply, the interpolation would be written in device (8) enable, activate the interpolation calculation. When a green rectangle as shown below is displayed under the button, it means that interpolation is enabled, otherwise the interpolation function is turned off. www.eyc-tech.com...
Page 15
“clear chart” or ui start up export Y-axis label On/Off X-axis label On/Off secondary Y-axis On/Off chart legend On/Off data log function On/Off The X-axis scale adjustment The Y-axis scale mode ※Set recording time interval File > Log Interval Select recording interval www.eyc-tech.com...
Page 16
Air Flow Venturi Thermal Mass Flow Meter ※Export/recording measurement 1. export measurement data since the last “clear chart” or ui start up 1-1. clock Display > Export 1-2. Specify the file path and file name > Save www.eyc-tech.com...
Page 17
Note: If the specified file already exists, the data will be overwritten. 2. Record measurement data: record data since the Log function is turn on 2-1. Clock Display > Log(OFF) 2-2. Specify the file path and file name > Save > Log(ON) www.eyc-tech.com...
Page 18
Note: If the specified file already exists, the data will be overwritten. 2-3. Finish recording measurement data: Click Log(ON) again. At this time, the button returns to displaying Log(OFF), and the recorded data file is stored in the specified file. www.eyc-tech.com...
Page 19
(4) Factory Mode Status, default Disable (5) Firmware Checksum (6) Output equipment, supports analog output and relay functions (7) Supported Unit Conversion (8) Totalizer function, default enable (9) Temperature Calibration Points (10) Analog Output Calibration points (11) Calibration Date (10) (11) www.eyc-tech.com...
Page 20
2 – Totalizer 1 (5) unit of counter 1 (6) unit of counter 2 (7) Main switch of totalizer (8) Function switch of totalizer 1 (9) Function switch of totalizer 2 (10) Ser/Reset Totalizer 1 (11) Set/Reset Totalizer 2 (10) (11) www.eyc-tech.com...
Check bypass channel ⚫ The straight length of pipe did ⚫ Check dust and not satisfy design specifications. contamination on the Refer to the section 4. sensor Installation ⚫ Cleanup the bypass channel ⚫ Calibrate ⚫ Replace the sensor www.eyc-tech.com...
Page 22
Air Flow Venturi Thermal Mass Flow Meter eyc-tech Measuring Specialist enhance your capability with sensor technology Air flow | Humidity | Dew point | Differential pressure | Liquid flow Temp. | Pressure | Level | Air quality | Signal meter Tel.:886-2-8221-2741...