Page 1
USER MANUAL MANUALE D’USO BM 9804 DXT 9000 DESK-TOP PAGING MICROPHONE BASE MICROFONICA DA TAVOLO PER SISTEMA DXT 9000 BM 9804FM DXT 9000 FIREMEN’S WALL-MOUNTED PAGING MICROPHONE BM 9804 IN VERSIONE PER VIGILI DEL FUOCO (CON CASSETTA DA PARETE) www.acornfiresecurity.com...
www.acornfiresecurity.com TABLE OF CONTENTS INDICE ENGLISH SAFETY PRECAUTIONS DESCRIPTION CONNECTION FRONT PANEL PAGING MICROPHONE SETTINGS (display menu) BM 9804FM – FIREMEN’S PAGING MICROPHONE SPECIFICATIONS ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE COLLEGAMENTO PANNELLO FRONTALE IMPOSTAZIONI DELLA BASE MICROFONICA (tramite menù sul display) UTILIZZO BM 9804FM –...
www.acornfiresecurity.com SAFETY PRECAUTIONS IMPORTANT IMPORTANT NOTES Before connecting and using this paging microphone, please read this instruction manual NOTES carefully and keep it on hand for future reference. The manual is to be considered an integral part of this product and must accompany it when changing ownership as a reference for correct installation and use as well as for the safety precautions.
It can be directly connected to a main unit (i.e. MU 9186, MX 9502, MX 9504) through a four-pair J-type fire-rated cable. It is possible to link up to sixteen BM 9804 paging microphones (or alterna- tively, the BM 9802 model, which has a numeric keyboard) to each main unit bus (total: max.
BM 9804FM BM 9804FM is the ‘Firemen’ paging microphone that works in the same way of the BM 9804 model, but with the following differences: The paging microphone is inside a wall-mounted metallic box (colour: red, RAL 3000) with glass.
Page 7
www.acornfiresecurity.com INPUT: RJ 45 port to be linked to either a DXT 9000 main unit PAGING IN port or the previous paging microphone OUTPUT. OUTPUT: RJ 45 port to be linked to the next paging microphone INPUT port. INPUT OUTPUT Audio signal (+, hot) Audio signal (+, hot) Audio signal (–, cold)
Page 8
BM 9804 SET FOR BM 9804 SET FOR EMERGENCY PURPOSES EMERGENCY PURPOSES WARNING: the internal switch setting shall be carried out only by either RCF or an authorised service centre. First, remove the rear cover by unscrewing its 6 screws.
Page 9
ADDITIONAL BE 9808 KEYBOARDS KEYBOARDS Up to eight BE 9808 (additional 8-zone-button) keyboards can be linked to every BM 9804 (each powered by an AC AD2405 adapter and not used for emergency purposes) to increase the number of available buttons. AC AD2405...
Page 10
Fix the first BE 9808 to the BM 9804 (and all BE 9808 to one another) by using the dedicated plate (included in the BE 9808 package) and four screws. 9804 9808 BLOCK DIAGRAM BLOCK DIAGRAM MU 9186 / MX 9502 / MX 9504...
BE 9808 keyboards) can be linked to each main unit bus (PAGING IN 1 and PAGING IN 2). Every BM 9804 needs a 24 Vdc – 500 mA power supply (not included, i.e. optional RCF AC AD2405). The first paging microphone of each bus can be used for emergency purposes (required by the EN 54-16 standard).
Page 12
www.acornfiresecurity.com PTT LED (green): when lit, the microphone is turned on (by pushing the PTT button GEN CALL (general call) button: push to select all zones. LED GEN CALL (green): when lit, it indicates the general call selection (by pushing the GEN CALL button).
www.acornfiresecurity.com PAGING MICROPHONE SETTINGS (DISPLAY MENU) All parameters are displayed in one of the 4 available languages: English, Italian, German and French. The first three (contrast, language choice and password) and the menu exit are always selectable, the others need the insertion of the correct password.
www.acornfiresecurity.com ¹ Parameters available only after inserting the correct password. Push the rotary encoder once to enter the menu. Turn it clockwise to scroll the menu downwards or increase the selected parameter value. Turn it counterclockwise to scroll the menu upwards or decrease the selected parameter value.
Page 15
www.acornfiresecurity.com 3. Press and hold down the PTT button 4. Verify the zone (/ group) selection is accepted (LEDs lit green): If yes, wait (a few seconds) the chime playing (if previously enabled) and talk a few inches from the microphone capsule. If not, it is not possible to call now, but you should wait until the selected zone (or groups) are free.
BM 9804FM – FIREMEN’S PAGING MICROPHONE BM 9804FM is the ‘Firemen’ paging microphone that works in the same way of the BM 9804 model, but with the following differences: The paging microphone is inside a wall-mounted metallic box (colour: red, RAL 3000) with glass.
SPECIFICATIONS BM 9804 Type: electret Polar pattern: cardioid Output impedance: 470 Ω (1 kHz) Microphone sensitivity: – 65 dB ± 3 dB (0 dB=1V/μbar, 1 kHz) Frequency response: 50 Hz ÷ 18 kHz (– 3 dB) Dimensions: 128 x 39 x 203 mm (without gooseneck) Gooseneck length: 445.5 mm...
Page 18
www.acornfiresecurity.com 0068 RCF S.p.A. - Via Raffaello Sanzio 13, 42124 Reggio Emilia, ITALY 0068-CPR-002/2014 EN 54-16:2008 Voice alarm control and indicating equipment for fire detection and fire alarm systems for buildings DXT 9000 Provided options Audible warnings 7.6.2 Manual silencing of the voice alarm condition 7.7.2 Manual reset of the voice alarm condition Output to fire alarm devices...
www.acornfiresecurity.com INDICE ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE COLLEGAMENTO PANNELLO FRONTALE IMPOSTAZIONI DELLA BASE MICROFONICA (tramite menù sul display) UTILIZZO BM 9804FM – CONSOLE D’EMERGENZA PER VIGILI DEL FUOCO DATI TECNICI www.acornfiresecurity.com...
www.acornfiresecurity.com AVVERTENZE PER LA SICUREZZA IMPORTANTE IMPORTANTE Prima di collegare ed utilizzare la base microfonica, leggere attentamente le istruzioni contenute in questo manuale, il quale è da conservare per riferimenti futuri. Il presente manuale costituisce parte integrante del prodotto e deve accompagnare quest’ultimo anche nei passaggi di proprietà, per permettere al nuovo proprietario di conoscere le modalità...
9186, MX 9502, MX 9504) tramite un cavo antifiamma di tipo “J” (quattro coppie di conduttori). È possibile collegare fino a sedici basi microfoniche BM 9804 (oppure, in alter- nativa, il modello BM 9802 con tastiera numerica) a ciascun “bus” dell'unità...
Page 22
BM 9804FM Il modello BM 9804FM è la versione per i vigili del fuoco, identica nel funzionamento alla base microfonica BM 9804, ma con le seguenti differenze: la base microfonica è protetta all’interno di una cassetta metallica (di colore rosso RAL 3000) con vetro ed installata a parete;...
Page 23
www.acornfiresecurity.com INPUT (ingresso): presa RJ 45 per il collegamento di una porta PAGING IN dell’unità centrale (del sistema DXT 9000) oppure alla presa OUTPUT della base microfonica precedente. OUTPUT (uscita): presa RJ 45 per il collegamento alla porta INPUT della base microfonica successiva.
Page 24
BM 9804 CON FUNZIONE BM 9804 CON FUNZIONE D’EMERGENZA D’EMERGENZA ATTENZIONE: l'impostazione del selettore interno deve essere effettuata direttamente da RCF oppure solo da un centro d'assistenza autorizzato. In primo luogo, rimuovere il coperchio posteriore svitando le 6 viti.
Page 25
PULSANTIERE PULSANTIERE ADDIZIONALI BE 9808 ADDIZIONALI BE 9808 Ogni base microfonica BM 9804 (se non usata per funzioni d’emergenza) può essere espansa con massimo otto pulsantiere aggiuntive BE 9808 (ciascuna con otto tasti addizionali). AC AD2405 BM 9804 BE 9808...
Page 26
Fissare la prima BE 9808 alla BM 9804 (e tutte le BE 9808 tra loro) usando l'apposita piastrina (inclusa nell'imballo della pulsantiera BE 9808) e quattro viti. 9804 9808 SCHEMA A BLOCCHI SCHEMA A BLOCCHI MU 9186 / MX 9502 / MX 9504...
BM 9804 (con o senza pulsantiere addizionali BE 9808). Ogni BM 9804 necessita di un alimentatore 24 V c.c. – 500 mA (non incluso, es. RCF AC AD2405 opzionale). La prima base microfonica di ciascun “bus” può avere funzione d’emergenza (come da norma EN 54-16).
Page 28
www.acornfiresecurity.com LED PTT (verde): se acceso, il microfono è stato attivato tramite il rispettivo tasto Tasto GEN CALL (chiamata generale): premere per selezionare tutte le zone. LED GEN CALL (verde): se acceso, indica la selezione in corso della chiamata generale tramite il rispettivo tasto Tasto ALARM (può...
Page 29
www.acornfiresecurity.com IMPOSTAZIONI DELLA BASE MICROFONICA (TRAMITE MENÙ SUL DISPLAY) Tutti i parametri sono visualizzati in una delle 4 lingue disponibili: inglese, italiano, tedesco e francese. I primi tre (contrasto, scelta della lingua e password) e l’uscita dal menù sono sempre accessibili, mentre le altre impostazioni richiedono prima l’inserimento della password corretta.
www.acornfiresecurity.com ¹ Parametro disponibile solo dopo l'inserimento della password corretta. UTILIZZO Premere una volta il controllo rotante per accedere al menù. Ruotarlo in senso orario per scorrere l'elenco dei parametri verso il basso o per incrementare il valore del parametro selezionato; ruotarlo in senso antiorario per scorrere il menù...
Page 31
www.acornfiresecurity.com 3. Premere e tener premuto il tasto PTT 4. Verificare che la selezione delle zone (o gruppi) sia stata accettata (LED accesi verdi): nel caso positivo, attendere (pochi secondi) la riproduzione del tono di preavviso (se precedentemente abilitato) e parlare a pochi centimetri dalla capsula microfonica;...
Page 32
PER VIGILI DEL FUOCO Il modello BM 9804FM è la versione per i vigili del fuoco, identica nel funzionamento alla base microfonica BM 9804 descritta in precedenza, ma con le seguenti differenze: la base microfonica è protetta all’interno di una cassetta metallica (di colore rosso RAL 3000) con vetro ed installata a parete;...