Thank you for having purchased an LMF product. It is the result of many years of experience, Thank you for having purchased an LMF product. It is the result of many years of experience, research and has been made with top quality materials and highly advanced technologies. The CE mark guarantees that the machine meets the made with top quality materials and highly advanced technologies.
Page 3
SYMBOLOGY ATTENTION DANGER HIGH RISK OF ELECTRIC SHOCK ATTENTION: AUTHORIZED PERSONNEL ONLY 1 – I NTRODUCTION pag. 4 2 - D IMENSIONS AND EIGHTS pag. 5 3 – T RANSPORTATION pag. 8 4 – I & C NSTALLATION ONNECTION pag. 9 5 –...
Page 4
Unit must be used only for this purpose, LMF will not respond in case of different use of the unit.
Page 5
2 – D IMENSIONS AND EIGHTS Packing dimensions The following table, referred to the figure, shows the characteristic dimensions of the series FLH and its accessories. S = Supply, E = Exhaust, R = Return F = Fresh air 2185 2185...
Page 6
Packing dimensions The following table, referred to the figure, shows the characteristic dimensions of the series FLR and its accessories. S = Supply, E = Exhaust, R = Return F = Fresh air 1525 1690 1690 1855 1195+865 1195+865 1195+1030 1030 1360 1690...
Page 7
Packing dimensions The following table, referred to the figure, shows the characteristic dimensions of the series FLS and its accessories. S = Supply, E = Exhaust, R = Return F = Fresh air 2185 2185 2515 2845 3175 3505 3835 1030 1360 1690...
3 – T RANSPORTATION ANDLING AND TORAGE Packaging Each unit is put on bench and protected with cellophane film; the protection must remain intact until the moment of installation. The materials that are not mounted for technical motives are supplied in fitted packing fixed externally or internally to the unit.
Storage The units must be stored in a dry place, sheltered from the sun, rain, sand and wind. Comply with the storage conditions given below: • Do not stack the units • Maximum temperature = 60°C • Minimum temperature = -20°C The Manufacturer declines any responsibility for any damage as a result of negligence or lack of protection from atmospheric agents.
Preliminary operations Check the perfect condition of the various components of the unit. • Control that contained within the packing, there are the installation accessories, and documentation. • Transport the packed section as close as is possible to the intended place of installation. •...
Air duct connections IMPORTANT: IT IS IMPORTANT NOT TO PLACE IN OPERATION THE UNIT IF THE FAN OUTLETS ARE NOT DUCTED OR NOT PROTECTED BY A SAFETY NET ACCORDING TO THE ACTUAL REGULATION. The ducts must be correctly sized, in order to match unit external static pressure at duty airflow rate. •...
Electrical connections Before starting any operation, insure that the general power supply has been isolated. All the electrical connections must be protected at the source by the installer. Qualified personnel according to the supplied schemes must carry out the electrical connections at the control panel. Insure that the voltage and the frequency shown on the technical plate correspond to the connecting power •...
Monthly maintenance Air filters Filter section can be entered through recessed handle side panels, after unlocking external panel locks; once entered, filter can be directly removed by side. These units are provided with soft bag filters; since they are not cleanable, check them monthly and replace them when dirty.