Installation Manual for Photovoltaic Module
Materials and technical specifications are subject to change without prior notice due to continuous
technology and product updates, Copyright©2023 owned by Sany Group. All files reserved no reprinting,
dissemination, sale or modification of this manual without written permission of Sany Group.
-2023
Installation Manual for Photovoltaic Module

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SYMN156TBD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SANY SYMN156TBD

  • Page 1 Materials and technical specifications are subject to change without prior notice due to continuous technology and product updates, Copyright©2023 owned by Sany Group. All files reserved no reprinting, dissemination, sale or modification of this manual without written permission of Sany Group.
  • Page 2: Table Of Contents

    Contents 1. General Information ..................1 1.1. Overview ....................1 1.2. Warnings....................1 2. Installation ..................... 3 2.1. Installation Safety ................. 3 2.2. Installation Condition ................4 2.2.1. Climate Condition ............... 4 2.2.2. Site Selection ................4 2.2.3. Tilt Angle Selection ..............5 2.3.
  • Page 3: General Information

    1. General Information 1.1. Overview Thanks for choosing PV modules (hereafter referred to as “modules”) from SANY Silicon Energy (Zhuzhou) Co., Ltd. In order to ensure that the PV modules are installed correctly, please read the following instructions carefully before installing and using the modules.
  • Page 4 Do not use the module to replace or partly replace roofs and walls of buildings. ⚫ Do not remove any part installed by Sany or disassemble the module. ⚫ Do not lift up the modules using the attached cables or the junction box.
  • Page 5: Installation

    When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposals at least free of charge. For more, please contact Sany or refer to the operation and maintenance guideline 2. Installation 2.1 Installation Safety...
  • Page 6: Installation Condition

    Limit working ambient temperature range: -40° C to + 70° C 2.2.2 Site Selection In most applications, Sany PV modules should be installed in a location where they can receive maximum sunlight throughout the year. In the Northern Hemisphere, the module should typically face south, and in the Southern Hemisphere, the modules should typically face north.
  • Page 7: Tilt Angle Selection

    1) All installation methods herein are only for reference, and are based on the test results from third- party tests and Sany internal tests; 2) Sany will not provide related mounting accessories, the system installer or trained professional personnel must be responsible for the PV system’s design, installation, and mechanical load calculation and system security.
  • Page 8: Fixed Installation-Mounting With Bolts

    The module must be mounted on the bracket according to the following installation. If there are other installation, please consult Sany group and obtain approval, otherwise the warranty will be invalid. Note: Maximum Test Load = 1.5 (Safety factor) x Design load 2.3.1 Fixed installation-mounting with bolts...
  • Page 9: Fixed Installation-Mounting With Clamps

    SYMN108TS SYMN108TBDB Table 2 Test loads under four inner bolt installation methods for different module types (Note: Other installation methods and load capacity not listed inTable 2, please contact Sany Silicon for more details) 2.3.2 Fixed installation-mounting with clamps -2023...
  • Page 10 The clamps must not be installed in contact with the front glass of the module and shall not deform the frame of the module. Make sure that the clamps do not create a shadow on the module. The frame must not be altered under any circumstances.
  • Page 11 clamp clamp Module frame Module frame M8 bolt Rail M8 bolt Rail Middle modules installation Fringe modules installation Fig. 5 PV module installed at the side with Clamp mounting 2.3.2.1 Different methods of clamp installlation Beam Bracket Fig.6 Clamp Installation method In Fig.6, A is the module length and B is the module width.
  • Page 12: Wiring And Connection

    When installing and connecting modules, the foam tube must be removed first, Sany will not guarantee the safety of products and the consistency of technical parameters if the connecting heads and tools used are not officially specified by Sany or are not installed according to the official requirements.
  • Page 13 Sany recommends two types of grounding: bolted grounding, shown in Figure 7, and clamp grounding. The bolts should be tightened when grounding is installed and no damage should be done to the module frame or the grounding wire.
  • Page 14: Maintenance And Care

    Sany Silicon Energy. 4.Maintenance and Care It is required to perform regular inspection and maintenance of the modules, especially during the warranty period. To ensure optimum module performance, Sany recommends the following maintenance measures: 4.1 Visual Inspection...
  • Page 15: Cleaning

    Never use abrasive material under any circumstances; c) In order to reduce the potential for electrical and thermal shock, Sany recommends to clean PV modules during early morning or late afternoon hours when solar irradiation is low and the modules are cooler, especially in regions with hot temperatures;...
  • Page 16: Electrical Specification

    No responsibility is assumed by Sany for any infringement of patents or other rights of third parties, which may result from use of the PV product. NO license is granted by implication or otherwise under any patent or patent rights.