CONCEALED SENSOR FLUSH VALVES
3200
3205
TOOLS NEEDED
Allen Wrench
Smooth Jaw
Wrench
Pipe Solder
Phillips Screwdriver
I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com
One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents
3 5
"
8
92
3 5
5 1
"
"
8
2
92
140
5 1
7 3
"
4
196
2 " WATERTIGHT
CONNECTOR
2 3
"
4
70
3 5
"
8
92
4 3
1
5 1
"
2 "
2
4
121±13
140
5 1
7 3
"
4
196
2 " WATERTIGHT
CONNECTOR
2 3
"
4
70
Pipe Cutter
Flat Head Screwdriver
T15H
Screwdriver
101929 : 3200 Series
PRIOR TO INSTALLATION
• All plumbing should be installed according to applicable state
and local codes and regulations.
• Before installation of the I-CON flush valve, ensure the water
COMMERCIAL CUTSHEET
closet or urinal fixture, drain line, and water supply line are
TO CHANGE
ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-CUTSHEET-TEMPLATE.sldstd
properly installed.
SET NORMAL LINE THICKNESS TO .004
SET THIN LINE THICKNESS TO .002
• Water supply lines must be sized to allow for appropriate water
ADJUST SHEET SCALE TO FILL PAGE
flow for each fixture.
SET FRACTIONAL DISPLAY TO VERTICAL
SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING
• Flush all water supply lines of any debris before making and
TEXT SHOULD BE ALL CAPS
"
2
DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)
connections.
140
• Do not use pipe sealant or plumbing grease on any components
TEMPLATE INFORMATION
PAGE SIZE 3"x3"
or couplings, with the exception of the control stop inlet.
CENTURY GOTHIC SIZE 8 FONT
• A smooth jaw or strap wrench should be used for installation
ONE-TIME SYSTEM SETTING CHANGE
to prevent damage to the finish of the I-CON flush valve and
DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK
SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK
components.
SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY
SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600
• Check to ensure the "L" dimension specified on the flush valve
packaging is correct for your application. "L" Dimension formula
is provided below.
"L" Dimension = Wall Thickness (to the nearest whole inch)
COMMERCIAL CUTSHEET
TO CHANGE
+ 2-3/4"
ANNOTATION SHOULD BE \\i-consystems.int\Operations\CAD Drawings\TEMPLATES\ANSI-CUTSHEET-TEMPLATE.sldstd
The I-CON flush valve is designed to operate at water pressures
SET NORMAL LINE THICKNESS TO .004
SET THIN LINE THICKNESS TO .002
ranging from 15 to 100psi (103 to 689kPa). The fixture type
ADJUST SHEET SCALE TO FILL PAGE
SET FRACTIONAL DISPLAY TO VERTICAL
determines the minimum pressure required for the valve. Most
SET BENT LEADER LENGTH TO 0.1" IN ANNOTATION AND DIMENSIONING
TEXT SHOULD BE ALL CAPS
low-consumption water closets are designed to operate with a
"
2
DUAL DIMENSION MEASUREMENT (MILLIMETER) SHOULD MATCH THE FRACTIONAL DISPLAY (INCHES)
140
minimum flowing water pressure of 25psi (172kPa).
TEMPLATE INFORMATION
PAGE SIZE 3"x3"
CENTURY GOTHIC SIZE 8 FONT
LIMITED WARRANTY
ONE-TIME SYSTEM SETTING CHANGE
DIMENSIONS NON-IMPORTED (DRIVEN) AND DIMENSIONS (DANGLING) SET TO BLACK
SKETCH (INACTIVE) AND SKETCH (UNDEFINED) SET TO BLACK
I-CON Systems, Inc. (I-CON) warrants that its commercial
SET PDF EXPORT LINES AND SHADED EDGES TO HIGH QUALITY
SET PDF EXPORT SHADED/DRAFT GEOMETRY AND SHARPENED OLE DPI TO 600
manufactured products are made of first-class materials, are
free from defects, and are made to withstand normal use when
installed properly. Products have the following warranty periods:
3 years for COBALT®, COBALT Pro®, and COBALT Connect®
faucets and flush valves and I-CON EDGE® gateways. 1 year for
all other products and decorative finishes. The warranty period
begins on the date of purchase.
Products should be sent to I-CON at the customer's expense.
I-CON will take a reasonable amount of time to determine if the
product is defective and whether it will be repaired or replaced.
During the warranty period, items will either be (1) repaired
at no charge using new replacement parts or (2) replaced with
either a new similar product or one manufactured from new
or serviceable used parts that are, at minimum a functional
equivalent to the original. The course of action will be
determined at I-CON's discretion. Replacement products that
are installed according to the instructions provided by I-CON will
assume the remaining warranty of the original product.
The limited warranty is only applicable to the product's materials
and workmanship. No claims for labor, transportation, or other
incidental or consequential costs will be allowed. No extended
warranties are available. THE SOLE AND EXCLUSIVE REMEDY
FOR ANY DEFECTIVE PRODUCT IS LIMITED TO REPAIRING OR
REPLACING THE DEFECTIVE PRODUCT. Before installing and
using products, the purchaser is responsible for determining the
products' suitability and assumes all risks and liabilities related
to the product.
This warranty only applies to persons and organizations that
purchase I-CON products directly from I-CON or an authorized
I-CON representative for the purpose of resale. This warranty
does not apply to the life of batteries or other consumables.
page 1
Rev 080824

Advertisement

loading
Need help?

Need help?

Do you have a question about the COBALT Pro 3200 and is the answer not in the manual?

Questions and answers

Summary of Contents for I-CON COBALT Pro 3200

  • Page 1 1 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...
  • Page 2 Turn on water supply and check for leaks. insertion. page 3 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...
  • Page 3 Install actuator cover on flush valve body. page 4 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...
  • Page 4 Loosen set screw on plate. Remove cover by pulling out then up. page 5 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...
  • Page 5 WALL SENSOR INSTALLATION - INSTALLATION WITHOUT ELECTRICAL BOX page 6 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...
  • Page 6: Interface Module Installation

    Close interface module. page 7 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...
  • Page 7 Ensure foreign objects, such as stall doors and mirrors, are not detected. page 8 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...
  • Page 8: Installation Complete

    0. INSTALLATION COMPLETE page 9 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...
  • Page 9: Programming Quick Reference

    DO NOT USE ACID OR ALCOHOL BASED CLEANERS. page 10 I-CON Systems, Inc., for product support call 1-866-730-7192 or visit us online at support.i-con.com Rev 080824 One or more products contained herein are protected by Patent with other undergoing the patent process www.i-con.com/patents...

This manual is also suitable for:

Cobalt pro 3205