Download Print this page

HEMCO UniFlow LE AirStream Installation, Operation & Maintenance Manual

Advertisement

Quick Links

Other HEMCO Products
UniFlow CE
AirStream
NSPE
UniFlow LE FM
UniFlow LE FM
NFPA
National Fire
Protection Association
Visit www.HEMCOcorp.com
HEMCO
HEMCO Corporation
711 S. Powell Road
Independence MO, 64056
Lab Planning Solutions
MM-SEFM-06.24
Made
In The
U.S.A.
UniFlow SE AireStream
High Performance
Energy Effi cient
Laboratory Fume Hoods
UniFlow LE
AirStream
SEFA
Scientifi c Equipment
and Furniture Association
Safety Equipment
AEE
ASME
Association of
American Society of
Energy Engineers
Mechanical Engineers
Phone (816) 796-2900
Fax. (816) 796-3333
R
Email: info@HEMCOcorp.com
Installation, Operation, Maintenance Manual
UniFlow SE FM Floor Mounted Fume Hood
HEMCO
Visit www.HEMCOcorp.com
Lab Planning Solutions
HEMCO Corporation
711 S. Powell Road
Independence MO, 64056
R
Email info@HEMCOcorp.com
Phone (816) 796-2900
Fax (816) 796-3333

Advertisement

loading
Need help?

Need help?

Do you have a question about the UniFlow LE AirStream and is the answer not in the manual?

Questions and answers

Summary of Contents for HEMCO UniFlow LE AirStream

  • Page 1 Installation, Operation, Maintenance Manual Other HEMCO Products UniFlow SE FM Floor Mounted Fume Hood Made In The U.S.A. UniFlow CE UniFlow SE AireStream AirStream High Performance Energy Effi cient Laboratory Fume Hoods UniFlow LE AirStream SEFA Scientifi c Equipment and Furniture Association...
  • Page 2 If the equipment has been damaged in transit, immediately notify and fi le a claim with the carrier. Do not return to HEMCO. If this procedure is not followed, the carrier will reject the claim and the consignee will suff er the loss. Please notify HEMCO so that we may help you in anyway possible with evaluation, repair, replacement, and valuation of the damage that has occurred.
  • Page 3 Drawings: UNPACKING INSTRUCTIONS FOR FM FLOOR MOUNTED FUME HOOD The HEMCO Fume Hoods are shipped palletized fully crated, padded and wrapped for maximum protection and ease of handling. If damaged call the adjuster for the delivering carrier promptly and notify HEMCO at 1-800-779-4362.
  • Page 4: Troubleshooting

    HEMCO TROUBLE SHOOTING info@HEMCOcorp.com HEMCO Corporation Laboratory Planning Solutions Fax (816) 796-3333 711 South Powell Road www.HEMCOcorp.com Tel (816) 796-2900 Independence, MO 64056 PROBLEM CAUSE CORRECTIVE ACTION 1) Improperly sized blower 1) Resize blower, change drive package 2) Motor (impeller wheel) is...
  • Page 5: Safety Recommendations

    HEMCO SAFETY RECOMMENDATIONS info@HEMCOcorp.com HEMCO Corporation Laboratory Planning Solutions Fax (816) 796-3333 711 South Powell Road www.HEMCOcorp.com Independence, MO 64056 Tel (816) 796-2900 - AVOID UNNECESSARY DO NOT - USE HOOD UNLESS EXHAUST EXPOSURE OF PERSONNEL SYSTEM IS IN OPERATION.
  • Page 6 Any questions? Call HEMCO customer service at 1-816-796-2900. Install upper sash stop blocks from sash Install Lower Sash into tracks, unroll cables tracks to allow the upper sash to pass to the and insert into holes above pulleys.
  • Page 7 HEMCO FUME HOOD OPERATION / MAINTENANCE info@HEMCOcorp.com HEMCO Corporation Laboratory Planning Solutions Fax (816) 796-3333 711 South Powell Road www.HEMCOcorp.com Independence, MO 64056 Tel (816) 796-2900 1. Fume Hood must be set on the work surface or a fl at level surface.
  • Page 8 HEMCO FM Cable Diagram Upper & Lower Sashes, 2 weights info@HEMCOcorp.com HEMCO Corporation Laboratory Planning Solutions Fax (816) 796-3333 711 South Powell Road www.HEMCOcorp.com Tel (816) 796-2900 Independence, MO 64056 SASH CABLE SASH BLUE CABLE PULLEYS TO TOP SASH RED CABLE...

This manual is also suitable for:

Uniflow le fmUniflow ce airstreamUniflow se airestream