SAFETY WARNINGS Carefully read this manual prior to installing and/or using the device and store it in an accessible place. This device is a component that is part of complex installations: the electrician is responsible for drawing up the general diagram of the system and of the electrical connections outside the device itself.
CONTENTS Description Page Safety warnings General warnings Disposal Preliminary operations DESCRIPTION Connections Types of use USING THE DEVICE Display and keyboard Description and operation of the keys Wizard start-up Summary map USING THE DEVICE Description of the Home Page Main Menu Alarm Menu Settings Menu 3.4.1 Season...
DESCRIPTION CORE MCT 010 is a device that controls the temperature of the radiant heating circuit’s delivery water, the switching on/off of the boiler, the heat pump, the pump dedicated to the radiant heating circuit and the air treatment machines.
USING THE DEVICE DISPLAY AND KEYBOARD 3.5" colour display with 160x128 pixel resolution If the LED is lit steady, it means that the device is powered and set to On or Away from Home Power LED (Green) If the LED flashes, it means that the device is powered and set to OFF The LED turned off indicates that the device is not powered If the LED is lit steady, it means that the device was in communication on the R-Bus, but the communication broke off...
WIZARD START-UP Only for the initial start-up of the device (thus without any active configuration) will the “Wizard start-up” window from the Installer Menu appear, preceded for a few seconds by a window showing the firmware version installed on the device. With this guided procedure a few parameters are set in sequence to give the device an initial configuration on the basis of the type of system installed.
USING THE DEVICE DESCRIPTION OF THE HOME PAGE 17.4 °C 19.6 °C 27.9 °C 9:17 21/05/2023 Description Indicates the summer season and thus the “Cooling” mode Indicates the winter season and thus the “Heating” mode The icons are always lit steady. The icons flash when the season is being changed Green Indicates the “ON”...
Page 9
HOME PAGE 2/4 17.4 °C 19.6 °C 27.9 °C Description Indicates the percentage value of the mixing valve’s opening. The “*” symbol indicates that the valve opening value is set manually from the technical 8 % * menu If no mixing valve is mounted in the system, the field remains empty HOME PAGE 3/4 This page includes the information shown graphically above 17.4 °C...
HOME PAGE 4/4 17.4 °C Mixed Circ Pump Mixed Circ Pump ON ON Direct Circ Pump Direct Circ Pump Heat Pump Heat Pump Boiler Boiler ON ON Value Description Indicates the status of the mixed circuit pump. The possible values are ON, OFF or the time remaining to the pump’s activation during the start-up phase or the time remaining to its switching off after the mixed system has activated.
Buzze Buzzer r 3.4.6 CoRe MCT 010 CoRe MCT 010 + CoRe CONNECT (Fig. 1) (Fig. 2) With CoRe MCT installed without CoRe CONNECT (Fig. 1), all the menu items will be included. N.B.: “H/C mode” and “System State” may not be present in the menu if they are managed using digital inputs.
3.4.3 SUPPLY TEMPERATURE CORRECTION Allows the user to modify the supply temperature calculated in winter by adding an WIN SUPPLY TEMP offset that increases or decreases the value within a range between -20°C and +20°C. Modify the value using the keys then press to confirm and return to the previous menu.
TRM = (Terminal) CoRe Chrono TH, CoRe Air Control UTA = Air Treatment Unit, CoRe Air MU MCT (Central Heating Unit Module) = CoRe MCT 010 PRB (Probe) = CoRe T, CoRe TH, CoRe Air Speed MIO (Input Output Module) = CoRe MZ, CoRe Air FC For each type, the number of connected devices at the time of display compared to the total number connected to the R-Bus network will be shown.