User Manual Evodent E230 Evodent E128 User Manual...
Page 2
User Manual 一、Packing list Printer parameters: Item Unit Quantity Light curing 3D printer Resin tank Filter funnel Molding platform USB flash drive Curved tweezers Power adapter (built-in drive for Evodent E230, provided with 220V cable) Power cord 1 for Scraper knife (plastic, metal) each type Cutting pliers...
User Manual II. Product Dimensions 2.1 Evodent E128 0.01mm Molding area 128×81×100mm Resolution 2560×1620...
Page 4
User Manual 2.2 Evodent E230 0.01mm Molding area 221.4×129.6×190mm Resolution 9840×5760...
Page 5
1、 After opening the package, take out the power cord, the power adapter (NOTE: Evodent E230 has a built-in drive and can be connected directly to 220V power supply without an adapter) and the antenna, connect the power cord and the...
Page 6
User Manual 2. Gently press the power button to turn on the printer, the main menu as shown in Figure 3-2 will appear automatically when the printer is turned on. Figure 3-2...
Page 7
User Manual 3.2 Language 1. This device is configured in English when leaving the factory, as shown in Figure 3-3 and 3-4. Figure 3-3 Figure 3-4...
Page 8
User Manual 3.3 Remote connection Click the icon marked with ① in Figure 3-5 to enter the WIFI selection page and connect to WIFI, or connect to the Internet through the network port on the back of the device. ① ②...
Page 9
User Manual Figure 3-6 Enter the address displayed in your browser to access the Dashboard, as shown in Figure 3-7: Figure 3-7 3.4 Leveling operation This device has been calibrated for levelness at the factory, and is ready for printing upon receipt. After a long time of use, and due to factors such as external force, the printing platform may become misaligned and need to be re-leveled.
Page 10
User Manual shown in Figure 3-8 to enter the platform leveling mode shown in Figure 3-9. Figure 3-8 Figure 3-9 2、After entering the platform leveling mode, make sure that the four fixing screws of the platform are loosened and there is no foreign matter on the exposure screen, place a piece of A4 paper on the screen, and click [Next] to lower the platform.
Page 11
4、After the above operation, click [Complete] to finish the leveling operation, as shown in Figure 3- Figure 3-10 ②: Evodent E230 1. Click [Platform Leveling] on the main menu as shown in Figure 3-11 to enter the platform leveling mode shown in Figure 3-12.
Page 12
User Manual Figure 3-12 2. After entering the platform leveling mode, make sure that the four fixing screws of the platform are loosened and there is no foreign matter on the exposure screen, place a piece of A4 paper on the screen, and click [Next] to lower the platform.
Page 13
User Manual screws to repeat the pre-tightening operation until a feeling of pulling can be felt equally at the four corners. 4. After the above operation, click [Complete] to finish the leveling operation, as shown in Figure 3-13. Figure 3-13 3.5 Preparations before printing 1.
Page 14
User Manual state. Figure 3-14 Figure 3-15 2. The exposure process starts after clicking on the corresponding exposure pattern, the exposure screen will show the same pattern as on the display screen, as shown in Figure 3-16.NOTE: If the exposure screen does not display pattern...
Page 15
User Manual Figure 3-16 3. After the exposure test, clean the curing screen and the bottom of the resin tank with alcohol, return the resin tank to its original position after making sure that there are no impurities that will interfere with the printing operation, and then tighten two of the locking screws as shown in Figure 3-17, after which the resin required for printing can be added to the...
Page 16
User Manual Figure 3-17 3.6 Printer settings 1、To turn on or off the uniform light mode, click [Setting] on the main menu as shown in Figure 3-18 to enter the printer settings page shown in Figure 3-19. Click the icon shown in the red box in Figure 3-19 to turn on or off the uniform light mode.Status icons: (On)
Page 17
User Manual When performing any printing operation with this mode enabled, the printer will perform the printing parameters that are set in the file to be printed, such as exposure time, bottom layer count, and speed. When performing any printing operation with this mode disabled, the printer will perform the printing parameters set in the device.Status icons:...
Page 18
User Manual Figure 3-20 Figure 3-21 6. Model printing: Click [Models] on the main menu as shown in Figure 3-22 to enter the model selection page, as shown in Figure 3-23. Figure 3-22...
Page 19
User Manual Figure 3-23 Find the document required for printing in the list and click it, and the device is in the print mode when the screen is as shown in Figure 3-24. Figure 3-24 After entering print mode, click the triangle icon on the panel to start printing, as shown in Figure 3-25.
Page 20
User Manual Figure 3-26 3.7 Cleaning of resin tank Click [Tools] on the main menu as shown in Figure 3-27 to enter the submenu page as shown in Figure 3-28, and click [Clear Residue] to enter the resin tank cleaning page as shown in Figure 3- Figure 3-27...
Page 21
User Manual Figure 3-28 Figure 3-29 After clicking [Next], the exposure screen enters the full-screen exposure state, as shown in Figure 3-30, follow the steps shown to clear the curing sheet, and then click [Confirm] to complete the resin tank cleaning procedure, as shown in Figure 3-31.
Page 22
User Manual Figure 3-30 Figure 3-31 四、Maintenance and Cleaning 1. If the Z-axis makes a friction noise during operation, please apply an appropriate amount of lubricant to the Z-axis screw. 2. Please do not use sharp objects to scrape or shovel the release film to avoid scratching or puncturing the release film.
Page 23
User Manual consumables back to the storage tank (the residue needs to be filtered out with filter paper before the consumables can be put back). 5. After the printing operation, clean the platform and the residue in the resin tank to prevent the consumables from solidifying.(Wipe clean with paper towels or use alcohol for cleaning.) 6.
Page 24
User Manual the plug of the device.(The risk of electrical leakage will certainly increase if the device is not grounded or not properly grounded, or its plug is modified.) 4. Do not misuse the power cord, always use the original power cord provided by the manufacturer. 5.