Carilex VT 100 Service Manual

Carilex VT 100 Service Manual

Negative pressure wound therapy system
Hide thumbs Also See for VT 100:

Advertisement

Quick Links

VT 100 NEGATIVE PRESSURE WOUND THERAPY SYSTEM
SERVICE MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VT 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Carilex VT 100

  • Page 1 VT 100 NEGATIVE PRESSURE WOUND THERAPY SYSTEM SERVICE MANUAL...
  • Page 2: Table Of Contents

    VT 100 Negative Pressure Wound Therapy System Service Manual Table of Contents General Information Page Introduction Symbols Reference Safety Precautions Warnings Maintenance – Level 1 Page Introduction Tools Required Power Unit Part Identification Overview Control Panel Reference General Maintenance General Cleaning Instructions...
  • Page 3 VT 100 Negative Pressure Wound Therapy System Service Manual Table of Contents Maintenance and Repair – Level 2 Page Introduction Tools Required Power Unit Part Identification Overview Replacing the Top Case Replacing the Control PCBA Replacing the Solenoid Valve Set...
  • Page 4: General Information Page

    VT 100 Negative Pressure Wound Therapy System Service Manual General Information A. Introduction This Carilex Service Manual provides repair and maintenance instructions for the VT 100 System. Any trained maintenance staff member can perform the procedures described in the sections of this manual that are designated Level 1.
  • Page 5: Symbols Reference

    VT 100 Negative Pressure Wound Therapy System Service Manual B. Symbols Reference Follow Instructions for use Class II Equipment Type BF Applied Part WEEE Logo subject to WEEE Directive 2012/19/EU Issued by Notified Body Number 2460 Catalogue number Caution Authorized representative in the European Community...
  • Page 6: Safety Precautions

    Risk of Electric Shock: DO NOT open back cover. This device is NOT user serviceable. This device should only be opened by qualified personnel approved by Carilex. Refer all service to your local Carilex authorized dealer. Oxygen Equipment: Explosion risk if used in the presence of flammable anesthetics Electrical: Do not insert items into any opening of the power unit.
  • Page 7: Introduction

    VT 100 Negative Pressure Wound Therapy System Service Manual Maintenance - Level 1 A. Introduction Any trained maintenance staff member can perform the procedures described in the sections of this manual that are designated Level 1. B. Tools Required PH2 Screwdriver...
  • Page 8: Power Unit

    VT 100 Negative Pressure Wound Therapy System Service Manual Power Unit A. Part Identification Overview Control Panel / Panel Foil VT100 Canister PVC Tube Tube Clamp Air Outlet Docking Ports Power Socket Power Switch Battery Compartment Fig: 1 Document #: M-1-S1001-Q001...
  • Page 9: Control Panel Reference

    VT 100 Negative Pressure Wound Therapy System Service Manual B. Control Panel Reference 1 Power Button 2 Mute/Return Button 3 Backlight Button 4 Up Button 5 OK/Unlock/Pause Button 6 Down Button 7 LCD Display Fig: 2 Document #: M-1-S1001-Q001 Revision: 1.1...
  • Page 10: General Maintenance

    VT 100 Negative Pressure Wound Therapy System Service Manual C. General Maintenance Body and Docking Ports Thoroughly inspect the body casing and panel foil for any damage, such as cracks, where moisture might get inside. Remove the canister from the unit then inspect and clean the docking ports, checking for any signs of foreign matter or damage.
  • Page 11: General Cleaning Instructions

    VT 100 Negative Pressure Wound Therapy System Service Manual General Cleaning Instructions ALWAYS UNPLUG THE POWER UNIT BEFORE CLEANING NEVER SPRAY LIQUIDS DIRECTLY ONTO A POWER UNIT NEVER IMMERSE A POWER UNIT IN ANY LIQUID Routine Cleaning During Use Dampen a clean cloth with soap and water or a mild, neutral detergent and then wipe the power unit.
  • Page 12: Replacing The Panel Foil

    VT 100 Negative Pressure Wound Therapy System Service Manual F. Replacing the Panel Foil NEVER SPRAY LIQUIDS DIRECTLY ONTO A POWER UNIT IF LIQUID IS ALLOWED INTO THE CASING OF THE POWER UNIT, EXTENSIVE DAMAGE MAY RESULT The panel foil is held in place by a self-adhesive backing. Use a small, thin, flat bladed knife to pry up an edge and gently pull the panel foil to remove it.
  • Page 13: Introduction

    Be sure to seal the power unit with a new Do Not Open sticker after carrying out any of the procedures designated Level 2 and fill out a Product Service Record and email to Carilex Medical Inc. or to your distributor.
  • Page 14: Power Unit

    VT 100 Negative Pressure Wound Therapy System Service Manual Power Unit A. Part Identification Overview Fig: 14 Top Case Set Control PCBA and LCD Display Rear Case Set Solenoid Valve Set Power PCBA Set Power Adapter Vacuum Motor Front Case Set Battery Set 10.
  • Page 15: Replacing The Top Case

    VT 100 Negative Pressure Wound Therapy System Service Manual B. Replacing the Top Case Follow the instructions in “Replacing the Panel Foil” to remove the panel foil. Remove the four screws from the top of the power unit. (Fig: 15) Remove and lay aside the top case.
  • Page 16: Replacing The Solenoid Valve Set

    VT 100 Negative Pressure Wound Therapy System Service Manual Replacing the Solenoid Valve Set Follow the steps in “Replacing the Control PCBA” to remove the control PCBA. Disconnect the solenoid valve connector and silicone tube from the control PCBA. (Fig: 17) Disconnect the solenoid valve silicone tube from the docking port.
  • Page 17: Replacing The Front Case

    VT 100 Negative Pressure Wound Therapy System Service Manual Replacing the Front Case Follow the steps in “Replacing the Control PCBA” to remove the top case and the screws securing the control PCBA. Follow the steps in “Replacing the Bottom Case” to remove the bottom case.
  • Page 18: Replacing The Power Pcba

    VT 100 Negative Pressure Wound Therapy System Service Manual Replacing the Power PCBA Follow the steps in “Replacing the Front Case” to remove the front case. Remove the two screws from the power PCBA. (Fig: 25) Remove the power PCBA connector from the control PCBA. (Fig: 17)
  • Page 19: Replacing The Rear Case

    VT 100 Negative Pressure Wound Therapy System Service Manual I. Replacing the Docking Port Set Follow the steps in “Replacing the Front Case” to remove the front case. Remove the silicone tubes from the docking ports. (Fig: 19 and Fig: 27) Slide the docking port set out of the rear case.
  • Page 20: Introduction

    VT 100 Negative Pressure Wound Therapy System Service Manual Testing A. Introduction The procedures described in this section of the manual can be carried out by any trained member of staff. B. Tools Required Multimeter with DC voltage mode Manometer with negative pressure reading Document #: M-1-S1001-Q001 Revision: 1.1...
  • Page 21: Power Unit

    VT 100 Negative Pressure Wound Therapy System Service Manual Power Unit A. Function Test Stage Steps  Power On Plug the power adapter into the wall socket and into the power unit  Switch the wall socket on  Switch the power switch on the power unit on ...
  • Page 22: Battery Voltage Test

    VT 100 Negative Pressure Wound Therapy System Service Manual B. Battery Voltage Test The battery should be charged and voltage tested every six months. Follow the steps in “General Maintenance – Battery” to remove the battery from the power unit.
  • Page 23: Alarm Test

    VT 100 Negative Pressure Wound Therapy System Service Manual C. Alarm Test The following test can be used to check that the alarm is functioning correctly. 1. Remove the canister from the power unit. 2. Switch the power switch on the bottom of the power unit on.
  • Page 24: Introduction

    VT 100 Negative Pressure Wound Therapy System Service Manual Troubleshooting A. Introduction The procedures described in Troubleshooting that are marked Level 2 must only be carried out by manufacture- authorised service personnel. All other procedures in described in Troubleshooting can be carried out by any trained maintenance personnel.
  • Page 25: Power Unit

    VT 100 Negative Pressure Wound Therapy System Service Manual B. Power Unit Battery Power No Backlight Call for Failure Troubleshooting Guidelines Supply / No Display Service Symbol Symbol  Check that the power adapter is connected to the wall socket ...
  • Page 26 VT 100 Negative Pressure Wound Therapy System Service Manual High System Target Target Continuous Unresponsive Pressure Pressure Troubleshooting Guidelines Alert to Buttons Reached Reached  Level 2: Check that the button PCBAs on the control PCBA are connected correctly (Fig: 34) ...
  • Page 27: Product Service Record

    VT 100 Negative Pressure Wound Therapy System Service Manual Product Service Record F101.03 General Information Date: Service Technician: Company: Location: Product Serviced: Serial Number: Device Article Number: Invoice Number: In Warranty Yes / No General Problems Description: Parts Replaced Serial Number...