Summary of Contents for Morsettitalia 884116

  • Page 1 Pagina 1 Page 33 Page 65 Seite 97 8 8 4 1 1 6 U n i v e r s a l T r a n s m i t t e r V e r s i o n n o . 1 0 3 R e v i s i o n d a t e 0 9 / 0 9...
  • Page 2: Table Of Contents

    Off N.C. On N.C. On N.C. On N.C. Off N.C. How to demount 884116 ........... 38 When front LED lights red / display shows AO.ER .... 38 azione relè: aumento azione relè: Diminuisci Advanced features ............. 39 Application ................. 39 Descrizione grafica dell’azione finestra del relè...
  • Page 3: Warning

    Class II. insTal- laTion 884116 must be mounted on a DIN rail according to DIN 46277. mounTing: Only technicians who are familiar with the technical terms, warnings, and instruc tions in the manual and who are able to follow these should connect the Warning device.
  • Page 4: Ec Declaration Of Conformity

    To the extent that the instructions in this manual are not strictly observed, the customer cannot advance a demand against Morsettitalia S.p.A. that would otherwise exist according to the concluded sales agreement. Rønde, 28 August 2009 Filippo Codara...
  • Page 5: How To Demount 884116

    • Galvanic separation of analogue signals and measurement of floating signals. off and then switching on the supply voltage to the device. • The 884116 is designed according to strict safety requirements and is thus suit able for application in SIL 2 installations.
  • Page 6: Technical Characteristics

    Relays application • Communications interface for modification of operational parameters in 884116. • Can be moved from one 884116 device to another and download the configuration of the first transmitter to subsequent transmitters. 10 V 10 V • Fixed display for readout of process data and status.
  • Page 7: Order Codes

    EMC immunity influence ........< ±0.5% of span 884116 = universal transmitter Extended EMC immunity: 884501 = Display / programming front NAMUR NE 21, A criterion, burst ....... < ±1% of span 5910 = CJC connector Auxiliary supplies: 2-wire supply (terminal 44...43) ....
  • Page 8: Visualisation In The 884501 Of Sensor Error Detection And Input Signal Outside Range

    R1 (relay 1), ERR.ACT=NONE Current output: R2 (relay 2), ERR.ACT=NONE, Signal range (span) ........0...20 mA 884116 OUT.ERR=NONE. Programmable signal ranges ...... 0...20 / 4...20 / 20...0 and 20...4 mA Else: Load (max.) ..........20 mA / 800 Ω / 16 VDC...
  • Page 9: Sensor Error Detection Limits

    11 12 21 22 11 12 Check measurement of analogue output current AO.ER put (only S4...20/S20...4 mA) Communications test 884501 / 884116 NO.CO Connection error Check that input signal matches input configuration IN.ER 1) Error levels on input Check that saved configuration in 884501 matches device TY.ER...
  • Page 10: Block Diagram

    Documentation for routing diagram. in general: Voltage When configuring the 884116, you will be guided through all parameters and Potentiome ter you can choose the settings which fit the application. For each menu there is a scrolling help text which is automatically shown in line 3 on the display.
  • Page 11 See the latch menu structure on page 59. When the setpoint is exceeded the relay outputs enters an alarm state. The latch function of the 884116 will hold the relays in this state until the function...
  • Page 12 advanced functions selection of units The device gives access to a number of advanced functions which can be After choosing the input signal type you can choose which process units should reached by answering “Yes” to the point “adv.set”. be displayed in text line 2 (see table). By selection of temperature input the process value is always displayed in Celsius or Fahrenheit.
  • Page 13: Routing Diagram

    rouTing Diagram Power up Fast setpoint adjustment If no key is activated for 1 minute, the display will return to the default 50.0 and relay test state 1.0 without saving configuration changes. RELAY1 1 Increase setpoint Txt 57 1 Increase value / choose next parameter 2 Decrease setpoint 2 Decrease value / choose previous parameter 75.0...
  • Page 14 S20-4 20-4 SETP 20-0 HOLD WIND HOLD S4-20 CLOS CLOS 23mA 4-20 OPEN 3600 3600 N.O. 9999 INCR 250.0 OPEN 3600 3600 VOLT 0/3.5mA 4172 4172 0-20 NONE 0000 0000 N.C. -1999 DECR NONE 0000 0000 CURR NONE -328 -328 NONE SETP N.O.
  • Page 15 rouTing Diagram rouTing Diagram Latch Advanced settings (ADV.SET) 2.0 In the submenu simulation (SIM) you must DISP press 3 to return to the default state 1.0. SAVE PASS LOAD LANG SAVE SETUP MEMORY Txt 43 Txt 44 A.OUT DISP A.OUT 40.0 SETUP CONTRA...
  • Page 16 Select TC-W5 as sensor type Enter relay latch setup Select TC-Lr as sensor type [44] Load saved configuration into 884116 [19] Select OFF function - relay is permanently off Save 884116 configuration in 884501 Select POWER function - relay indicates power status OK...
  • Page 17: Graphic Depiction Of Latch Function Setpoint

    graphic depiction of latch function setpoint graphic depiction of latch function window Input ON delay signal OFF delay Setpoint (increasing) Hysteresis Time Relay latched Closed Relay contact (N.O.) Open Release not possible (setpoint still exceeded) Release not possible (setpoint-hysteresis still exceeded) Release not possible (OFF delay still exceeded) Release possible (manuel deactivation)
  • Page 18: Graphic Depiction Of Relay Action Setpoint

    Déclaration de conformité CE ..........69 Off N.O. On N.O. Off N.O. Off N.O. On N.O. Off N.O. Démontage du 884116 ............70 On N.C. Off N.C. On N.C. On N.C. On N.C. Off N.C. Quand la LED rouge s’allume / l’indicateur affiche AO.ER .. 70 Options avancées...............
  • Page 19 (für steigendes Signal angezeigt) relaisfunktion: fenster (für fallendes Signal angezeigt) Kontakt: Geschlossen im Fenster = Kontakt: Geschlossen im Fenster = Kontakt: Geöffnet im Fenster = Kontakt: Geöffnet im Fenster = Morsettitalia S.p.A. Via Santi, 87 20037 Paderno Dugnano (MI) www.morsettitalia.com...