Type:
Job:
Transformer Catalog number:
Transformer
Specifications
enclosure: Formed 16 ga. stainless steel enclosure with integral
hinge. Cover is secured with two stainless steel screws. A through
hole is provided in the bottom edge for a padlock (by others). K"
knockouts on each side of the enclosure are provided for hardwiring
or accessory photocell mounting.
Transformer: Core and coil type fully epoxy encapsulated. Output
is multi-tap 12V / 13V / 14V / 15V. The 200 and 300-watt units have
single circuit output, the 600-watt unit has two circuits for output.
Variable taps provide flexibility in system design with the 12 volt tap
for fixtures near the transformer location and higher voltages for more
remote fixtures.
Terminal Block: 80-amp euro-style terminal block.
Circuit Breaker: 25 amp magnetic circuit breaker (1) per circuit.
Cord: Six foot, heavy duty outdoor power cord is provided
and installed.
Certification: UL Listed to U.S. and Canadian safety standards for
wet locations. Fixture manufacturer shall employ a quality program
that is certified to meet the ISO 9001:2000 standard.
K"
(12.7 mm)
knockouts
5C"
(3 places)
(136.5 mm)
(139.7 mm)
15"
(76.2 mm)
(381.0 mm)
(177.8 mm)
KLV600 – 200 watt
KLV605 – 300 watt
K"
(12.7 mm)
knockouts
6K"
(3 places)
(165.1 mm)
17"
(431.8 mm)
KLV625 – 900 watt
KiM liGHtinG rEsErvEs tHE riGHt to CHanGE sPECifiCations WitHout notiCE.
© 2014 KIM LIGHTING • 16555 East GalE avEnuE, City of industry, Ca 91745-1788 • tEl: 626/968-5666 • faX: 626/968-5716
Transformer Options:
Ordered Separately from Transformer
K"
(12.7 mm)
knockouts
5K"
(3 places)
(165.1 mm)
3"
(381.0 mm)
7"
KLV620 – 600 watt
5K"
(139.7 mm)
3"
(76.2 mm)
8"
(203.2 mm)
Above-Grade and In-GradeTransformers
OrDerING INfOrMATION
Cat. No.
l KLV600 200 watt (1) circuit
l KLV605 300 watt (1) circuit
l KLV620 600 watt (2) circuits 120V #18-2 SJTW
l KLV625 900 watt (3) circuits 120V #12-3 SJTW
l No Option
NOTe:
each circuit. Weather conditions must be considered
when determining load on transformers, hot weather
areas should reduce the output wattage to prevent
heat build-up on circuit breakers. The voltage at each
fixture must not exceed 12 volt. Load and distance
6K"
5K"
must be considered when determining which voltage
(139.7 mm)
tap to use. A good maintenanceprogramis required to
3"
replace lamps as they burn out to preventover-voltage
15"
(76.2 mm)
of remaining lamps.
7"
(177.8 mm)
Above-Grade
Transformer Accessories (Ordered separately from
fixture)
Cat. No.
l KLV-PC1
l KLV-PC2
l KLV-TC24
revision 8/25/14 • kl_12vtransformer_spec.pdf
Approvals:
Date:
Page: 1 of 4
Above Grade
Transformers
Description
Output wattage is not to exceed 25 amps on
Description
Photocell, Direct mount to enclosure
knockout
in
transformer enclosure.
Photocell, Remote mount with 10'
cord for installation in any K" NPT
cover plate (by others).
Plug-in Time Clock, Plugs into
receptacle provided in transformer
enclosure.
12 Volt
Input Cord
120V #18-2 SJTW
120V #18-2 SJTW
right-handside
of
5630509071
Need help?