AUSTART 2 Series Installation And Maintenance Manual

Turbine starter
Hide thumbs Also See for 2 Series:

Advertisement

INSTALLATION AND
MAINTENANCE MANUAL
AUSTART ATS73-2
SERIES 2
TURBINE STARTER
K.H. EQUIPMENT PTY. LTD.
10-16 WESTPOOL DRIVE, HALLAM, VICTORIA, 3803, AUSTRALIA
PH: +61 3 8786 4766
FX: +61 3 9796 4878
info@khequipment.com.au
www.austart.com
Issue: 05/04/2016 Rev.01
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for AUSTART 2 Series

  • Page 1 INSTALLATION AND MAINTENANCE MANUAL AUSTART ATS73-2 SERIES 2 TURBINE STARTER K.H. EQUIPMENT PTY. LTD. 10-16 WESTPOOL DRIVE, HALLAM, VICTORIA, 3803, AUSTRALIA PH: +61 3 8786 4766 FX: +61 3 9796 4878 info@khequipment.com.au www.austart.com Issue: 05/04/2016 Rev.01...
  • Page 2 THIS MANUAL CONTAINS IMPORTANT SAFETY INFORMATION. IT IS IMPORTANT THAT THE ENTIRE CONTENTS BE STUDIED BEFORE INSTALLATION AND OPERATION. IT ONLY REFLECTS GENERIC INFORMATION RELATING TO A STANDARD AUSTART ATS73-2 TURBINE STARTER. VARIOUS OTHER OPTIONS ARE AVAILABLE TO PROVIDE INERTIA DRIVE SYSTEMS, MUFFLERS OR THREADED EXHAUSTS TO MEET SPECIFIC APPLICATION REQUIREMENTS.
  • Page 4 PRELIMINARY INSTALLATION REQUIREMENTS Numbers in brackets refer to item numbers on Exploded View drawing on page 8. 1. Your AUSTART Starter is flange mounted. required. Pinion should be FRG less 1/8” Before installing the starter carefully study (3mm) when at rest.
  • Page 5 5. Determine the practicality of running the installed before the relay valve will provide 1”air supply hose or pipe from the exit of protection to the valve and AUSTART the ‘Y’ strainer to the inlet of the AUSTART starter from contaminants that may have starter after...
  • Page 6: Installation Schematic

    INSTALLATION SCHEMATIC...
  • Page 7: General Arrangement

    GENERAL ARRANGEMENT...
  • Page 8: Exploded View

    EXPLODED VIEW...
  • Page 9: Parts Breakdown

    PARTS BREAKDOWN...
  • Page 10: Section View

    SECTION VIEW...
  • Page 11: Maintenance

    MAINTENANCE WARNING DISASSEMBLY Refer to the Exploded View and Cross Sectional View drawings on pages 8 &10. Begin by removing the two band clamps (8) 8. Support nose housing (43) and press out nose bearing (44) from the outside of nose and separate the three sub-assemblies;...
  • Page 12 6. It is recommended that when servicing your AUSTART Turbine Starter always replace 4. Check all bearings are free to rotate and complete repair kit contents. do not have excessive play between races. If in doubt replace questionable bearings.
  • Page 13 REASSEMBLY Refer to the Exploded View and Cross Sectional View drawings on pages 8 &10. Reassembly of any of the sub assemblies Fit o’ring (35) and wiper seal (37) onto piston (36). detailed in the exploded view on page 8 is basically in the reverse order shown.
  • Page 14 Tighten band clamp (8) to 4 ft lb (6Nm). (wrench) on the special flats provided. 2. The AUSTART Air Starter is now assembled 10. Install o’ring (10) onto turbine housing (14) ready installation.
  • Page 15: Warranty Policy

    This warranty shall not apply to any Austart Starter or parts which have been altered or repaired or purchased outside the Manufacturer and its assigned agents nor to equipment or parts that have been subject to misuse including overloading, neglect, accident or damage, nor to any part or parts improperly applied or installed.
  • Page 16 NOTES DISTRIBUTED BY...

This manual is also suitable for:

Ats73-2

Table of Contents