Quick Start Guide Foreword General This manual introduces the installation, functions and operations of the IR illuminator (hereinafter referred to as "the Illuminator"). Read carefully before using the device, and keep the manual safe for future reference. Safety Instructions The following categorized signal words with defined meaning might appear in the manual. Signal Words Meaning Indicates a high potential hazard which, if not avoided, will result...
Page 3
Quick Start Guide might result in some differences appearing between the actual product and the manual. Please contact customer service for the latest program and supplementary documentation. ● There might be errors in the print or deviations in the description of the functions, operations and technical data.
Quick Start Guide Important Safeguards and Warnings This section introduces content covering the proper handling of the device, hazard prevention, and prevention of property damage. Read carefully before using the device, comply with the guidelines when using it, and keep the manual safe for future reference. Transportation Requirements ●...
Page 5
Quick Start Guide ● The device is a class I electrical appliance. Make sure that the power supply of the device is connected to a power socket with protective earthing. ● An emergency disconnect device must be installed during installation and wiring at a readily accessible location for emergency power cut-off.
1 Overview 1.1 Introduction The DH-PFM522 series IR illuminator is a smart illuminator. You can control the on and off of the Illuminator according to different scenarios. The Illuminator uses an imported LED chip as the light source. With a precise optical design, the light intensity can be evenly and effectively distributed, and achieve the overall highlighting effect and provide professional supplementary light for video monitoring, vehicle and pedestrian detection and capture.
Quick Start Guide 2 Structure 2.1 Appearance Figure 2-1 Appearance Table 2-1 Component description Port Port description Decide whether to light up according to the Photosensitive tube scenarios. Grounding hole Ground through the grounding screw. 12 V input cable Inputs 12 VDC. Connects to cameras controlled by RS–485.
Quick Start Guide 3 Installation The illuminator is classified into RG 0 according to related laws and regulations. ● To protect the photosensitive components from being soaked by rain and affecting the normal operation, we recommend you face down the photosensitive components during installation, and avoid strong light towards the components.
Page 11
Quick Start Guide and then adjust the bracket to the specific position. The bracket does not come with the delivery. Buy it if it is necessary. Table 3-1 Bracket diagram Bracket model Diagram Pole mount Wall mount Plane mount...
Quick Start Guide 3.2 Cable Connection 3.2.1 Connecting the cables For details on lightning and surge protection, see "Appendix 2 Lightning and Surge Protection". Figure 3-2 Cable connection Table 3-2 Component description Component Illuminator Air circuit breaker Lightning protector Check if the adapter is needed: ●...
Quick Start Guide Make sure to install the Illuminator upright and place the connection part downward. Figure 3-3 Upright installation ● Drilling a hole under the waterproof pipe. Put the cables in the waterproof pipe, and drill a hole under the pipe to prevent water from accumulating.
Page 14
Quick Start Guide mode, and then the Illuminator will turn on or off according to the outdoor environment in one minute. If the RS–485 signal is connected and the signal is sent, the Illuminator answers to the corresponding signals. Table 3-3 Mode description Mode Description Connects to RS–485 signals according to label description to control the on-...
Quick Start Guide 4 FAQ This section introduces the frequently occurred problems and solutions during the installation and use. Table 4-1 Problems and solutions Problem Reason Solution ● Power input parameters are wrong. ● Power cord is poorly connected. ● The Illuminator is broken. ●...
Page 16
Quick Start Guide Problem Reason Solution ● There are devices with large power in the area where the Illuminator works. The controlling chip of the After working for a Illuminator is broken caused Contact customer service. while, the Illuminator flickers and turns off. by overvoltage.
IP video surveillance is not immune to cyber risks, but taking basic steps toward protecting and strengthening networks and networked appliances will make them less susceptible to attacks. Below are some tips and recommendations from Dahua on how to create a more secured security system.
Page 18
Quick Start Guide information changes, please modify it in time. When setting password protection questions, it is suggested not to use those that can be easily guessed. Enable Account Lock The account lock feature is enabled by default, and we recommend you to keep it on to guarantee the account security.
Page 19
to private networks. Enable IP/MAC address filtering function to limit the range of hosts allowed to access the device. More information Please visit Dahua official website security emergency response center for security announcements and the latest security recommendations.
Quick Start Guide Appendix 2 Lightning and Surge Protection The Illuminator adopts TVS lightning protection technology. It can effectively prevent damage from various pulse signals, such as a sudden lightning and surge. However, you still need to take necessary precaution measures in accordance with your local electrical safety code when installing the Camera in outdoor environment.