Advertisement

OPERATION MANUAL
429EBP
ARINC 429 TX/RX
MANUAL NUMBER: E6-1001-13 / 75555
REVISION: A2
DATE: 06/04/2015
WARNING: INFORMATION SUBJECT TO EXPORT CONTROL LAWS
This document contains controlled technology or technical data under the jurisdiction of the Export
Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party
without the specific prior approval of the U.S. Department of Commerce Bureau of Industry and Security
(BIS). Violations of these regulations are punishable by fine, imprisonment, or both.
This document is proprietary to Advanced Technical Group, and is not to be reproduced or otherwise
disseminated without the written consent of Advanced Technical Group.
nd
14046 Northwest 82
Avenue
Miami Lakes, FL
33016
Telephone: (305) 556-1957
Fax: (305) 556-6510
www.a-tg.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 429EBP and is the answer not in the manual?

Questions and answers

Summary of Contents for ATG 429EBP

  • Page 1 OPERATION MANUAL 429EBP ARINC 429 TX/RX MANUAL NUMBER: E6-1001-13 / 75555 REVISION: A2 DATE: 06/04/2015 WARNING: INFORMATION SUBJECT TO EXPORT CONTROL LAWS This document contains controlled technology or technical data under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party without the specific prior approval of the U.S.
  • Page 2 REVISION HISTORY – 429 EBP OPERATION MANUAL E6-1001-13 / 75555 / 10000020914 06-1001-13 / 3511 / 10000020915 Revision Date Reason Reference 12/13/10 Correct typo in Specifications 500000001254 10/17/11 Add phone plug drawing 500000002312 06/04/15 Update Document for ATG 2  June 4, 2015  Rev. A2   ...
  • Page 3 REV. DRAWING NO. LEVEL DRAWING NO. LEVEL Table of Contents Section I Section II Section III Section IV Section V Appendix A DRAWING REVISION HISTORY – 429EBP – June 4, 2015 – PAGE 1 OF 1 3  June 4, 2015  Rev. A2   ...
  • Page 4 ATG 429EBP Operation Manual    ELECTROSTATIC DISCHARGE GENERAL WARNINGS FOR ALL EQUIPMENT THIS EQUIPMENT MAY CONTAIN ELECTROSTATIC DISCHARGE (ESD) SENSITIVE CAUTION: COMPONENTS. TO PREVENT ESD SENSITIVE EQUIPMENT FROM POSSIBLE DAMAGE, OBSERVE THE FOLLOWING PRECAUTIONS WHEN HANDLING ANY ESD SENSITIVE COMPONENTS, OR UNITS CONTAINING ESD SENSITIVE...
  • Page 5: Table Of Contents

    3.1.2  ENG MODE .........................  3 ‐1  3.1.3  TRANSMIT & RECEIVE MODES ...................  3 ‐1  3.1.4  IDLE MODE .........................  3 ‐3  3.2  CONTROL FUNCTIONS  ........................  3 ‐4  3.2.1  429EBP CONTROLS AND INDICATORS  ................  3 ‐4  3.3  OPERATING EXAMPLE ........................  3 ‐8  3.3.1  TRANSMITTER FUNCTIONS ....................  3 ‐9  3.3.2  RECEIVER FUNCTIONS ......................  3 ‐10  3.3.3  USING THE RECEIVER TRAP FUNCTIONS ................  3 ‐11 ...
  • Page 6 ATG 429EBP Operation Manual    5  MAINTENANCE  ...........................  5 ‐1  5.1  BILLS OF MATERIAL, ASSEMBLY DRAWINGS, SCHEMATICS & TEST PROCEDURES ....  5 ‐1  6  Appendix ............................  6 ‐1  6  June 4, 2015  Rev. A2   ...
  • Page 7: General Information

    ARINC 429 avionics systems. The 429EBP has unique label definitions designed to facilitate the testing of Boeing aircraft avionics. The 429EBP can transmit up to 10 independent ARINC 429 labels simultaneously and can receive and store up to 4096 words (8192 words without label or rate information in the DATA ONLY TRAP mode).
  • Page 8: Units And Accessories Applied

    ±2 msec. average Input Impedance: 12K ohms minimum (balanced) 1.4 UNITS AND ACCESSORIES APPLIED 1. ATG Model 429EBP - ARINC 429 Transmitter Receiver JPN 01-1001-12 2. STANDARD Accessory: 110V/60Hz to 9VDC Battery Charger JPN 15-0009-03 OPTIONAL Accessory: 220V/60Hz to 9VDC Battery Charger JPN 15-0009-02 3.
  • Page 9: Installation

    2.3.2 CONNECTION TO USER EQUIPMENT Connect the ATG 429EBP output (TX jack) to the input of the UUT and the 429EBP input (RX jack) to the output of the UUT using standard 1/4 inch stereo phone jacks. 2.3.3 JUMPER PLUG FABRICATION Jumper plugs should be fabricated using 2-conductor braided shield cable.
  • Page 10: Post Installation Check

    This indicates that U3 has failed its test. The unit will then loop indefinitely reading from the failed location. The 429EBP has a loop back feature on the digital board to completely test the digital portion of the transmit and receive circuitry. The unit will turn on the loop back circuitry and transmit a word with a label of 0 and a data pattern of AA55AA.
  • Page 11: Operation

    3.1 GENERAL OPERATION DESCRIPTION The ATG 429EBP is a single channel ARINC 429 transmitter and receiver. It can receive and display all ARINC 429 labels. It can simultaneously output up to ten 429 words. Data can be displayed and entered in hexadecimal or engineering formats.
  • Page 12 4 msec or as long as 59998 msec. On label entry the word rate defaults to the minimum word rate defined in the ARINC 429-11 specs. The 429EBP also has the capability of transmitting words only on user command (SINGLE SHOT). Each slot can be programmed independently for this mode by programming the word rate for that slot to 1ms (SNGL SHOT).
  • Page 13: Idle Mode

    (keypad, TX, or RX) for at least 5 minutes. When this happens, the 429EBP will shut down some of its circuitry and go to `Sleep'. In this state, the 429EBP is fully functional, but it is in a low current drain wait state.
  • Page 14: Control Functions

    IN TX MODE: On/Off key for TX data PROTECT mode. If Protect is on the Transmit parameters will be protected when the 429EBP is powered off. AUTO Mode Key IN RX MODE: On/Off key for `AUTO' scrolling mode. Allows the operator to scroll through labels that have been received by TRAP mode.
  • Page 15 ATG 429EBP Operation Manual    PARITY Indicator IN RX MODE: LED Indicates parity (ODD or EVEN) of word presently displayed. IN TX MODE: LED Indicates selected transmit parity. (10) HEX/ENG Switch Allows operator to select hexadecimal or engineering unit display and entry of data.
  • Page 16 (18) Allows the internal batteries to be charged by Battery Charging Jack connecting to the battery charger furnished with the 429EBP. (19) Parallel Printer Output Port Allows connection to an IBM compatible parallel printer using a standard IBM/CENTRONICS parallel interface cable.
  • Page 17 Up to 3 hex characters may be entered. Pressing this key again or any other mode control key will clear this screen. The Equipment Identifier is used by the 429EBP to determine which ARINC definition to use for the received and transmitted labels when displaying and entering data.
  • Page 18: Operating Example

    035 DME FREQUENCY 102 SEL ALTITUDE The 429EBP hand held, transmitter/receiver features are designed to allow the user greater flexibility when working with ARINC 429 data buses. These features are outlined below. 1. Expanded screen displays of data and information.
  • Page 19: Transmitter Functions

    Entering Transmit Labels and Protecting Data Turn on the 429EBP (unit will self test and go to the receive mode). To clear the transmitter if it contains labels, depress the trap key displaying NOT PROTECTED and turn unit off for 5 seconds then back on.
  • Page 20: Receiver Functions

    In this manner you will see displayed the four labels entered previously on the transmitter side. NOTE: If there are any labels trapped in the memory of the 429EBP they will enunciate on the screen. To clear the memory depress the TRAP key; or the F/FILT key if XX FILTERED WORDS appears.
  • Page 21: Using The Receiver Trap Functions

    ATG 429EBP Operation Manual    3.3.3 USING THE RECEIVER TRAP FUNCTIONS 3.3.3.1 General Trap Mode 1. To trap the first 4096 labels received, depress the TRAP key. Unit will display TRAP LABEL, depress ENT, unit will display DATA ?, depress ENT, unit will display TRIG LABEL, depress ENT, unit will display DATA ?, depress ENT and unit will begin trapping.
  • Page 22 600003 = SSM and SDI bits only checked, (bits 31 & 32 and 9 & 10) Other bit parameters may be set as desired. When viewing the 429EBP screen the display in the hex mode shows the following information: XXXXXX...
  • Page 23: Filter Mode

    (006 is the ID code found in the ARINC specification that identifies labels used for Air Data Systems.) 4. The 429EBP will now display 035 BARO (IN) which is inches of mercury used for air data testing. Note that label 034 has also been changed and it now displays 034 BARO (MB).
  • Page 24: Theory Of Operation

    Display Board (P/N 20-6782-10) Digital Board (P/N 20-6784-40) Analog Board (P/N 20-6783-00) 4.1.1 DISPLAY BOARD The Display board performs the human interface function for the 429EBP. It has three major sections of circuitry: Display circuits Keypad circuits Slide Switch circuits The Display circuits output data in visual form.
  • Page 25: Analog Board

    3. Baud Clock/Bit Counter (U5) 4. Driver Enable (1/2 U8) 4.1.3 ANALOG BOARD The Analog board contains the analog circuitry for the 429EBP. This circuitry has three major sections: Power Circuits 429 Receiver 429 Driver The Power circuits supply power to the system from one of two sources. If the battery charger is disconnected, the circuits supply power to the system from the battery pack.
  • Page 26 MAINTENANCE BILLS OF MATERIAL, ASSEMBLY DRAWINGS, SCHEMATICS & TEST PROCEDURES To assist in the maintenance of the 429EBP, bills of material, assembly drawings, schematics and test procedures are contained in the 429EBP Maintenance Manual (P/N E6-1001-12 / 75554), available separately from ATG.
  • Page 27 ATG 429EBP Operation Manual    Appendix EBP Ver 1.0 BOEING SPECIAL LABELS See Note 1 See Note 2 LABEL EQ ID/SDI BUS DESCRIPTION RANGE UNITS 029/0 EICAS Ail Pos Inner L 0-360 Degrees 029/1 EICAS Ail Pos Outer L 0-360 Degrees 029/2 EICAS...
  • Page 28 ATG 429EBP Operation Manual    LABEL EQ ID/SDI BUS DESCRIPTION RANGE UNITS 029/0 EICAS Discrete Word #8 029/1 EICAS Discrete Word #9 029/2 EICAS Discrete Word #10 029/3 EICAS Discrete Word #11 029/0 EICAS Discrete Word #12 029/1 EICAS Discrete Word #13 029/2...
  • Page 29 ATG 429EBP Operation Manual    LABEL EQ ID/SDI BUS DESCRIPTION RANGE UNITS 029/0 EICAS Eng EPR Act. Right Ratio 029/1 EICAS Eng Fuel Press L Ratio 029/2 EICAS Eng Fuel Press R Ratio 029/3 EICAS Eng EPR Cmd Left Ratio 029/0 EICAS Eng EPR Cmd Right...
  • Page 30 ATG 429EBP Operation Manual    LABEL EQ ID/SDI BUS DESCRIPTION RANGE UNITS 029/0 EICAS Discrete Word #32 029/1 EICAS Discrete Word #33 029/2 EICAS Discrete Word #34 029/3 EICAS Discrete Word #35 029/0 EICAS Aft Trim Valve 0-128 % Open 029/1 EICAS Flight Deck Trim...
  • Page 31 ATG 429EBP Operation Manual    LABEL EQ ID/SDI BUS DESCRIPTION RANGE UNITS 029/0 EICAS Gross Weight 0-1310720 Lbs. 029/1 EICAS IDG Temp Rise-L ±2048 Deg. C. 029/2 EICAS IDG Temp Rise-R ±2048 Deg. C. 029/3 EICAS Inlet Tot Press-L 0-32 029/0 EICAS Inlet Tot Press-R...
  • Page 32 ATG 429EBP Operation Manual    LABEL EQ ID/SDI BUS DESCRIPTION RANGE UNITS 0D0/1 Hy Oil Pressure-L 0-4096 0D0/2 Hy Oil Pressure-R 0-4096 03D/x AVM Command Word Discrete 04D/x FQIS Unique Decoding in Trap Mode 04D/x FQIS Tot Fuel Quantity 0-655360 Lbs. 04D/x FQIS...
  • Page 33 ATG 429EBP Operation Manual    LABEL EQ ID/SDI BUS DESCRIPTION RANGE UNITS 0D0/1 Vibration-L 0-5.12 Scaler 0D0/2 Vibration-R 0-5.12 Scaler 03D/x Highest Vibration 0-5.12 Scaler 03D/x N1 Vibration 0-5.12 Scaler 03D/x N2 Vibration 0-5.12 Scaler 03D/x N3 Vibration 0-5.12 Scaler 03D/x BB Vibration 0-5.12...

This manual is also suitable for:

Arinc 429 tx/rx

Table of Contents

Save PDF