IPK-62B DRAIN PUMP Installation Manual - Under-Counter Ice Machine - In Door Use Only NOTICE 1. DRAIN PUMP MUST BE CONNECTED TO ICE MACHINE 2. VENT TUBE MUST BE ATTACHED AND SECURED. 3. ALL HOSE CLAMPS MUST BE WATER TIGHT.
For safe use and installation, make sure you fully understand the method of use described in the manual and test the pump. Incorrect installation may result in damage to property. In such cases, Icetro America will not be liable for any damage or loss. Contents 1.
For safe use and installation, make sure you fully understand the method of use described in the manual and test the pump. Incorrect installation may result in damage to property. In such cases, Icetro America will not be liable for any damage or loss. 2. Tools Required for Installation...
Page 4
6) Remove the two screws connecting the water supply and drain bracket to the cabinet (Fig.4). 7) Gently pull the bracket forward and completely remove the tube between the ice bin and the back of the drain socket (Fig.5) Fig. 4 Fig.
Page 5
10) Remove the existing drain hose at the bottom of the drain box (Fig.8). 11) Cut the new drain pump air hose in line with the outlet at the bottom of the existing drain box.( Red line) (Fig.8). 12) After inserting the air hose of the drain pump, fix it with a clamp so that it does not come off (Fig.
Page 6
14) Remove the plastic covering from the ice maker’s connector and separate the jumper section (Fig.12). 15) Securely attach the pump connection to the ice maker connection making sure to match the order of the wire colors at both ends (Figure 13). Replace the plastic covering over the connectors and secure it with a cable if necessary using the cable tie provided.
Method of installation(for IU-0090-AN) 6) Move the operation switch to the "OFF" position, then unplug the appliance from the electrical outlet. 7) ) Remove the upper rear panel and lower vent-cover (Fig. 21). 8) Remove the drain bracket screws using a Phillips-head screwdriver (Fig. 22). 9) Loosen the hose clamps with pliers and disconnect the drain hose(Fig .23,24) Fig.
Page 8
13) Connect the drain pump's upper hose and the drain valve's lower 'Y' drain hose and secure it with a clamp(Fig.29,30). 14) Connect the drain pump 'Y' hose and the ice bin drain outlet and secure it with a clamp.(Fig.31,32) ! CAUTION Connect the hose carefully so that there is no leakage, and secure it with a clamp.
Page 9
19) Connect the drain tube to the brass machine drain fitting using the provided clamp. (Fig.37). 20) Reassemble the drain bracket by replacing the screws (Fig.38). Fig. 37 Fig. 38 22) Open the front door of the product, and unscrew the front-cover and remove it (Fig.40).
! CAUTION • An air vent should be installed; If not, overload may affect the drain pump. Ensure the air vent hose has not been folded over. • Connect the drain tube to a suitable drain. There should be 2-inches of space between the drain tube and the drain. The tube should not be bent or folded;...
7. Measures against malfunction Note : Connect the hose carefully so that there is no leakage, and secure it with a clamp. 1) When the ice machine does not work: - Check whether power is supplied to the wall consent. - Check whether the ice machine is turned on.